Ludovico Alisi, Premanand Chandran, Mrunali M Dhavalikar, Niklank Mehta, Padmavathy A Sivakumar, Abhipsa Sahu, Rohan A J Daniel, Ganesh V Raman
{"title":"Optimal Dimension of Peripheral Iridotomy for Anatomical Efficacy in Primary-Angle-Closure Disease.","authors":"Ludovico Alisi, Premanand Chandran, Mrunali M Dhavalikar, Niklank Mehta, Padmavathy A Sivakumar, Abhipsa Sahu, Rohan A J Daniel, Ganesh V Raman","doi":"10.3390/vision10020027","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study is to determine the optimal functional size of laser peripheral iridotomy (LPI) for anterior chamber parameter improvement in primary angle-closure disease (PACD). This study evaluated 109 eyes from 62 consecutive phakic patients. Baseline and one-week post-LPI anterior segment OCT were utilized to measure anterior chamber volume (ACV), anterior chamber angle (ACA), and iridotomy dimensions. Data was analyzed using linear mixed-effects models (LMMs), generalized additive models (GAMs), and receiver operating characteristic (ROC) curves. Post-LPI, significant increases occurred in ACA 500 (+7.54°), ACV (+11.09 mm<sup>3</sup>), and gonioscopic grade. LMMs confirmed a positive association between iridotomy size and anatomical expansion. GAMs demonstrated a saturation effect for ACV improvement, plateauing at 0.1 mm<sup>2</sup> (narrow area) and 0.25-0.30 mm<sup>2</sup> (superficial area), while the ACA relationship remained predominantly linear. ROC analysis identified preliminary superficial area cutoffs of 0.14 mm<sup>2</sup> and 0.12 mm<sup>2</sup> as discriminators of above-median volumetric and angular response, respectively. These findings suggest that LPI size is an independent determinant of anatomical response, beyond simple patency. As a preliminary, hypothesis-generating target, a superficial iridotomy area of approximately 0.12-0.14 mm<sup>2</sup> was associated with above-median volumetric and angular response in this cohort. Prospective validation is required before these thresholds can be incorporated into clinical practice.</p>","PeriodicalId":36586,"journal":{"name":"Vision (Switzerland)","volume":"10 2","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2026-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13214826/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision (Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision10020027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this study is to determine the optimal functional size of laser peripheral iridotomy (LPI) for anterior chamber parameter improvement in primary angle-closure disease (PACD). This study evaluated 109 eyes from 62 consecutive phakic patients. Baseline and one-week post-LPI anterior segment OCT were utilized to measure anterior chamber volume (ACV), anterior chamber angle (ACA), and iridotomy dimensions. Data was analyzed using linear mixed-effects models (LMMs), generalized additive models (GAMs), and receiver operating characteristic (ROC) curves. Post-LPI, significant increases occurred in ACA 500 (+7.54°), ACV (+11.09 mm3), and gonioscopic grade. LMMs confirmed a positive association between iridotomy size and anatomical expansion. GAMs demonstrated a saturation effect for ACV improvement, plateauing at 0.1 mm2 (narrow area) and 0.25-0.30 mm2 (superficial area), while the ACA relationship remained predominantly linear. ROC analysis identified preliminary superficial area cutoffs of 0.14 mm2 and 0.12 mm2 as discriminators of above-median volumetric and angular response, respectively. These findings suggest that LPI size is an independent determinant of anatomical response, beyond simple patency. As a preliminary, hypothesis-generating target, a superficial iridotomy area of approximately 0.12-0.14 mm2 was associated with above-median volumetric and angular response in this cohort. Prospective validation is required before these thresholds can be incorporated into clinical practice.