Metrological Analysis of the Trueness of Prosthetic Metal Structures Obtained with Digital Methods.

Current health sciences journal Pub Date : 2026-01-01 Epub Date: 2026-03-31 DOI:10.12865/CHSJ.52.01.12
Miruna Anghel, Catalin Popa, Alexandra Roiban, Alexandru Andrei Iliescu, Ioana Mitrut, Petre Mărășescu, Iuliana Stan, Daniela Micu, Horia Octavian Manolea
{"title":"Metrological Analysis of the Trueness of Prosthetic Metal Structures Obtained with Digital Methods.","authors":"Miruna Anghel, Catalin Popa, Alexandra Roiban, Alexandru Andrei Iliescu, Ioana Mitrut, Petre Mărășescu, Iuliana Stan, Daniela Micu, Horia Octavian Manolea","doi":"10.12865/CHSJ.52.01.12","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of the study was to evaluate of the accuracy and trueness of 24 Co-Cr alloy copings obtained through four digital methods in order to obtain the validation and compare the results of two dental dedicated measurement software.</p><p><strong>Material and methods: </strong>In this study, we analyzed 24 crowns made of Cobalt-Chrome using 4 different techniques to obtain the finished piece. The prosthetic pieces had the same design and were divided into 4 study groups (6 per group) depending on the method of obtaining as follows: R- resin, W- wax, M- milling, S- sintering. Each STL file of each crown was superimposed using the alignment functions of both the Medit Crown Fit program and the Meshmixer alignment functions in order to quantify the accuracy by analyzing the deviation from the design.</p><p><strong>Results: </strong>In total, over 6,720 references were generated, with approximately 280 images per layer. The results suggest that both software are capable of producing similar results in terms of deviation from design. The differences are below 0.01 mm, so they can be considered insignificant from a practical point of view. This confirms that both methods are eloquent in evaluating thicknesses regardless of the material.</p><p><strong>Conclusions: </strong>The measurement module integrated into 3D dental data allows for the precise quantification of various dental parameters, including interdental distances, angles, lengths and surfaces. This functionality is extremely valuable for prosthetic restorations, dental sizing and occlusion analysis, providing essential information for dental treatment planning.</p>","PeriodicalId":93963,"journal":{"name":"Current health sciences journal","volume":"52 1","pages":"104-117"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13198765/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current health sciences journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12865/CHSJ.52.01.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/31 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The aim of the study was to evaluate of the accuracy and trueness of 24 Co-Cr alloy copings obtained through four digital methods in order to obtain the validation and compare the results of two dental dedicated measurement software.

Material and methods: In this study, we analyzed 24 crowns made of Cobalt-Chrome using 4 different techniques to obtain the finished piece. The prosthetic pieces had the same design and were divided into 4 study groups (6 per group) depending on the method of obtaining as follows: R- resin, W- wax, M- milling, S- sintering. Each STL file of each crown was superimposed using the alignment functions of both the Medit Crown Fit program and the Meshmixer alignment functions in order to quantify the accuracy by analyzing the deviation from the design.

Results: In total, over 6,720 references were generated, with approximately 280 images per layer. The results suggest that both software are capable of producing similar results in terms of deviation from design. The differences are below 0.01 mm, so they can be considered insignificant from a practical point of view. This confirms that both methods are eloquent in evaluating thicknesses regardless of the material.

Conclusions: The measurement module integrated into 3D dental data allows for the precise quantification of various dental parameters, including interdental distances, angles, lengths and surfaces. This functionality is extremely valuable for prosthetic restorations, dental sizing and occlusion analysis, providing essential information for dental treatment planning.

数字方法获得的假体金属结构真实度的计量分析。
目的:评价4种数字化方法获得的24种Co-Cr合金镀层的准确性和真确性,并对两种牙科专用测量软件的结果进行验证和比较。材料和方法:在本研究中,我们分析了24个钴铬冠,使用4种不同的技术来获得成品。采用相同的设计,根据获得方法分为4个研究组(每组6个):R-树脂,W-蜡,M-铣削,S-烧结。利用Medit crown Fit程序的对齐函数和Meshmixer对齐函数对每个冠的STL文件进行叠加,通过分析与设计的偏差来量化精度。结果:总共生成了6720多篇参考文献,每层大约有280张图像。结果表明,这两个软件都能够产生类似的结果偏离设计。差异在0.01毫米以下,因此从实用的角度来看,它们可以被认为是微不足道的。这证实了两种方法在评估厚度时都是有效的,而不管材料是什么。结论:将测量模块集成到牙齿三维数据中,可以精确量化各种牙齿参数,包括牙间距离、角度、长度和表面。该功能对修复体、牙尺寸和咬合分析非常有价值,为牙科治疗计划提供了必要的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书