Rethinking intraoperative blood loss monitoring: a decision-oriented framework for clinically integrated assessment.

IF 1 Q3 EMERGENCY MEDICINE
International Journal of Burns and Trauma Pub Date : 2026-04-15 eCollection Date: 2026-01-01 DOI:10.62347/RYZE7872
Jiangtao Bai, Yutong Lu, Guilin Wang, Qihui Zheng, Haitao Jia, Zhilong Dong, Yunxin Zhang, Zhiping Wang
{"title":"Rethinking intraoperative blood loss monitoring: a decision-oriented framework for clinically integrated assessment.","authors":"Jiangtao Bai, Yutong Lu, Guilin Wang, Qihui Zheng, Haitao Jia, Zhilong Dong, Yunxin Zhang, Zhiping Wang","doi":"10.62347/RYZE7872","DOIUrl":null,"url":null,"abstract":"<p><p>Intraoperative blood loss (IBL) monitoring is an important factor in decision-making of anesthesia, and real-time and reliable IBL is vital in the safety of the patient during the perioperative period. But even now after decades of technological development in medicine, this basic clinical issue has not been addressed. The current strategies of monitoring do not usually achieve all the needs of accuracy, timeliness, and procedural flexibility in regular clinical care. This article re-examines this critical issue of intraoperative blood loss monitoring from the perspective of actual clinical surgery and anesthesiology. We analyzed the structural reasons for the long-term unreliability of IBL clinical measurements and proposed some core principles for future surveillance strategies. Traditional methods for assessing intraoperative blood loss include visual estimation, gravimetric methods, volumetric methods, and laboratory or spectrophotometric methods. These methods all have inherent limitations. We believe these shortcomings are not isolated technical problems, but rather stem from a design philosophy that did not address the needs of clinical decision-making from the outset. To better explain the clinical challenges faced by IBL monitoring, we propose the \"Irreconcilable Triangle of IBL Monitoring\" model. This model consists of three conflicting requirements: accuracy, timeliness, and workflow compatibility. Optimizing one dimension of technology inevitably compromises other dimensions. Therefore, we redefine accuracy as \"functional accuracy\". That is, the accuracy of intraoperative bleeding monitoring should reach the level necessary to support intraoperative clinical decision-making, without pursuing absolute accuracy. Simultaneously, it should be made as time-relevant and clinically feasible as possible to meet clinical needs. This paper envisions future strategies for intraoperative blood loss monitoring. Future clinical practice requires automated equipment capable of continuously quantifying free blood, absorbed blood, and blood clots, shifting from inferential estimation to direct automated measurement. Furthermore, this equipment must be seamlessly integrated into the anesthesia workflow. The paper discusses the availability of artificial intelligence (AI) in surgical blood loss monitoring. We believe that while AI has limitations in interpretability, it can serve as a complication prediction and backend computational tool for the entire monitoring system. In the future, we hope to develop IBL monitoring into an integrated system centered on clinical usability and decision relevance through new technology development and system integration.</p>","PeriodicalId":45488,"journal":{"name":"International Journal of Burns and Trauma","volume":"16 2","pages":"59-71"},"PeriodicalIF":1.0000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13195292/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Burns and Trauma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.62347/RYZE7872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Intraoperative blood loss (IBL) monitoring is an important factor in decision-making of anesthesia, and real-time and reliable IBL is vital in the safety of the patient during the perioperative period. But even now after decades of technological development in medicine, this basic clinical issue has not been addressed. The current strategies of monitoring do not usually achieve all the needs of accuracy, timeliness, and procedural flexibility in regular clinical care. This article re-examines this critical issue of intraoperative blood loss monitoring from the perspective of actual clinical surgery and anesthesiology. We analyzed the structural reasons for the long-term unreliability of IBL clinical measurements and proposed some core principles for future surveillance strategies. Traditional methods for assessing intraoperative blood loss include visual estimation, gravimetric methods, volumetric methods, and laboratory or spectrophotometric methods. These methods all have inherent limitations. We believe these shortcomings are not isolated technical problems, but rather stem from a design philosophy that did not address the needs of clinical decision-making from the outset. To better explain the clinical challenges faced by IBL monitoring, we propose the "Irreconcilable Triangle of IBL Monitoring" model. This model consists of three conflicting requirements: accuracy, timeliness, and workflow compatibility. Optimizing one dimension of technology inevitably compromises other dimensions. Therefore, we redefine accuracy as "functional accuracy". That is, the accuracy of intraoperative bleeding monitoring should reach the level necessary to support intraoperative clinical decision-making, without pursuing absolute accuracy. Simultaneously, it should be made as time-relevant and clinically feasible as possible to meet clinical needs. This paper envisions future strategies for intraoperative blood loss monitoring. Future clinical practice requires automated equipment capable of continuously quantifying free blood, absorbed blood, and blood clots, shifting from inferential estimation to direct automated measurement. Furthermore, this equipment must be seamlessly integrated into the anesthesia workflow. The paper discusses the availability of artificial intelligence (AI) in surgical blood loss monitoring. We believe that while AI has limitations in interpretability, it can serve as a complication prediction and backend computational tool for the entire monitoring system. In the future, we hope to develop IBL monitoring into an integrated system centered on clinical usability and decision relevance through new technology development and system integration.

重新思考术中出血量监测:一个决策导向的临床综合评估框架。
术中出血量(IBL)监测是麻醉决策的重要因素,实时可靠的IBL监测对围手术期患者的安全至关重要。但即使是现在,经过几十年的医学技术发展,这个基本的临床问题还没有得到解决。目前的监测策略通常不能满足常规临床护理的准确性、及时性和程序灵活性的所有需求。本文从实际临床外科和麻醉学的角度重新探讨术中出血量监测这一关键问题。我们分析了IBL临床测量长期不可靠的结构性原因,并提出了未来监测策略的一些核心原则。评估术中出血量的传统方法包括目测法、重量法、体积法和实验室或分光光度法。这些方法都有固有的局限性。我们认为这些缺点并不是孤立的技术问题,而是源于设计理念,从一开始就没有解决临床决策的需要。为了更好地解释IBL监测所面临的临床挑战,我们提出了“IBL监测的不可调和三角”模型。该模型由三个相互冲突的需求组成:准确性、及时性和工作流兼容性。优化技术的一个维度不可避免地会损害其他维度。因此,我们将准确度重新定义为“功能准确度”。即术中出血监测的准确性应达到支持术中临床决策所必需的水平,而不追求绝对的准确性。同时,应使其尽可能具有时效性和临床可行性,以满足临床需要。本文展望了术中失血监测的未来策略。未来的临床实践需要能够连续定量游离血、吸收血和血凝块的自动化设备,从推断估计转向直接的自动化测量。此外,该设备必须无缝集成到麻醉工作流程中。本文讨论了人工智能(AI)在外科失血监测中的可用性。我们认为,虽然人工智能在可解释性方面存在局限性,但它可以作为整个监测系统的复杂性预测和后端计算工具。未来,我们希望通过新技术开发和系统集成,将IBL监测发展成为一个以临床可用性和决策相关性为中心的综合系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
12.50%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书