[Assessment of patient and neurosurgeon radiation exposure using a direct-reading dosimeter during transpedicular fixation for thoracic and lumbar spine injuries].

Q4 Medicine
A Yu Kordonskiy, P B Popov, L I Beskin, A V Tupikin, V A Karanadze, E M Ivanov, R I Abdrafiev, A N Borodin, R S Saidov, A A Grin
{"title":"[Assessment of patient and neurosurgeon radiation exposure using a direct-reading dosimeter during transpedicular fixation for thoracic and lumbar spine injuries].","authors":"A Yu Kordonskiy, P B Popov, L I Beskin, A V Tupikin, V A Karanadze, E M Ivanov, R I Abdrafiev, A N Borodin, R S Saidov, A A Grin","doi":"10.17116/neiro20269003149","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Individual dosimetry is routinely performed using thermoluminescent dosimeters (TLDs). Total dose is accumulated in these devices and periodically recorded by an accredited laboratory. This method does not provide real-time information on intraoperative radiation exposure.</p><p><strong>Objective: </strong>To compare X-ray doses received by patients with traumatic thoracic and/or lumbar spine injury during open and minimally invasive interventions.</p><p><strong>Material and methods: </strong>Ninety-two patients underwent surgery for thoracic and/or lumbar spine injury. Intraoperative analysis included dose-area products (DAP, cGy×cm<sup>2</sup>), individual TLD dosimeter readings of surgeons. Individual radiation dose equivalent was determined using four direct-reading dosimeters positioned on the operating table at distances of 0, 40, 80, and 120 cm from direct beam of radiation source.</p><p><strong>Results: </strong>Fifty-four patients underwent open surgery, 38 - transcutaneous procedure. Mean DAP was 2171 cGy×cm<sup>2</sup>, mean radiation dose equivalent - 1.6 mSv. Minimally invasive procedures were associated with significantly higher radiation exposure: median DAP 3408.8 cGy×cm<sup>2</sup> and dose equivalent 2.3 mSv compared to 327.8 cGy×cm<sup>2</sup> and 0.2 mSv for open surgeries. Neurosurgeon radiation exposure did not exceed standards.</p><p><strong>Conclusion: </strong>Patient radiation exposure is significantly higher during minimally invasive procedures compared to open surgeries (mean dose equivalent 3 mSv versus 0.6 mSv). Understanding the patterns of radiation field is necessary for informed and safe use of X-rays.</p>","PeriodicalId":24032,"journal":{"name":"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko","volume":"90 3","pages":"49-57"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/neiro20269003149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Individual dosimetry is routinely performed using thermoluminescent dosimeters (TLDs). Total dose is accumulated in these devices and periodically recorded by an accredited laboratory. This method does not provide real-time information on intraoperative radiation exposure.

Objective: To compare X-ray doses received by patients with traumatic thoracic and/or lumbar spine injury during open and minimally invasive interventions.

Material and methods: Ninety-two patients underwent surgery for thoracic and/or lumbar spine injury. Intraoperative analysis included dose-area products (DAP, cGy×cm2), individual TLD dosimeter readings of surgeons. Individual radiation dose equivalent was determined using four direct-reading dosimeters positioned on the operating table at distances of 0, 40, 80, and 120 cm from direct beam of radiation source.

Results: Fifty-four patients underwent open surgery, 38 - transcutaneous procedure. Mean DAP was 2171 cGy×cm2, mean radiation dose equivalent - 1.6 mSv. Minimally invasive procedures were associated with significantly higher radiation exposure: median DAP 3408.8 cGy×cm2 and dose equivalent 2.3 mSv compared to 327.8 cGy×cm2 and 0.2 mSv for open surgeries. Neurosurgeon radiation exposure did not exceed standards.

Conclusion: Patient radiation exposure is significantly higher during minimally invasive procedures compared to open surgeries (mean dose equivalent 3 mSv versus 0.6 mSv). Understanding the patterns of radiation field is necessary for informed and safe use of X-rays.

[使用直读剂量计评估胸腰椎外伤经椎弓根固定期间患者和神经外科医生的辐射暴露]。
个体剂量测定通常使用热释光剂量计(tld)进行。总剂量累积在这些装置中,并由认可的实验室定期记录。这种方法不能提供术中辐射暴露的实时信息。目的:比较创伤性胸椎和腰椎损伤患者在开放和微创干预期间接受的x线剂量。材料和方法:92例胸椎和/或腰椎损伤患者行手术治疗。术中分析包括剂量-面积产品(DAP, cGy×cm2),外科医生个人TLD剂量计读数。分别在距离放射源直射束0、40、80和120 cm处放置4台直读式剂量计,测定个体辐射剂量当量。结果:54例患者行开放手术,38例经皮手术。平均DAP为2171 cGy×cm2,平均辐射剂量当量- 1.6 mSv。微创手术与较高的辐射暴露相关:中位DAP为3408.8 cGy×cm2,剂量当量为2.3 mSv,而开放手术的中位DAP为327.8 cGy×cm2,剂量当量为0.2 mSv。神经外科医生的辐射暴露没有超过标准。结论:与开放式手术相比,微创手术中患者的辐射暴露明显更高(平均剂量相当于3毫西弗对0.6毫西弗)。了解辐射场的模式对于知情和安全使用x射线是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
75
期刊介绍: Scientific and practical peer-reviewed journal. This publication covers the theoretical, practical and organizational problems of modern neurosurgery, the latest advances in the treatment of various diseases of the central and peripheral nervous system. Founded in 1937. English version of the journal translates from Russian version since #1/2013.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书