Quantitative Diagnostics of Hydroxyl (OH) Radicals in Methane-Air Flames Using Wavelength Modulation Spectroscopy with Correction for Water Spectral Interference.

IF 2.2 3区 化学 Q2 INSTRUMENTS & INSTRUMENTATION
Applied Spectroscopy Pub Date : 2026-07-01 Epub Date: 2026-05-26 DOI:10.1177/00037028261450621
Jiyeon Park, Aran Song, Changkook Ryu, Daehae Kim, Miyeon Yoo, Changyeop Lee
{"title":"Quantitative Diagnostics of Hydroxyl (OH) Radicals in Methane-Air Flames Using Wavelength Modulation Spectroscopy with Correction for Water Spectral Interference.","authors":"Jiyeon Park, Aran Song, Changkook Ryu, Daehae Kim, Miyeon Yoo, Changyeop Lee","doi":"10.1177/00037028261450621","DOIUrl":null,"url":null,"abstract":"<p><p>Exhaust gases generated by fossil fuel combustion significantly contribute to air pollution and climate change, emphasizing the need for efficient combustion diagnostics. OH radicals are key indicators of flame behavior; however, conventional laser-induced fluorescence (LIF) techniques are impractical for industrial monitoring due to their complexity. In this study, wavelength modulation spectroscopy (WMS) employing a near-infrared laser at 1.49 μm was used to measure OH radical concentrations, incorporating a correction for spectral interference from H<sub>2</sub>O. A wavelength division multiplexer (WDM) was used to enable the simultaneous operation of two lasers at 1.49 μm (OH) and 1.39 μm (H<sub>2</sub>O, temperature), allowing for correction of water interference. OH concentrations were determined using both WMS and direct absorption spectroscopy (DAS), and the results were evaluated through comparison with CHEMKIN simulations. The proposed dual-laser system demonstrated reliable and interference-corrected quantification of OH radicals in methane (CH<sub>4</sub>)/air premixed flames over a range of equivalence ratios. Comparisons with thermocouple-based temperature measurements and CHEMKIN-predicted species concentrations confirmed the reliability of the proposed technique. This study highlights the robustness and applicability of WMS-based OH diagnostics for combustion monitoring and demonstrates the potential for future implementation in industrial burner systems.</p>","PeriodicalId":8253,"journal":{"name":"Applied Spectroscopy","volume":" ","pages":"692-704"},"PeriodicalIF":2.2000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/00037028261450621","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Exhaust gases generated by fossil fuel combustion significantly contribute to air pollution and climate change, emphasizing the need for efficient combustion diagnostics. OH radicals are key indicators of flame behavior; however, conventional laser-induced fluorescence (LIF) techniques are impractical for industrial monitoring due to their complexity. In this study, wavelength modulation spectroscopy (WMS) employing a near-infrared laser at 1.49 μm was used to measure OH radical concentrations, incorporating a correction for spectral interference from H2O. A wavelength division multiplexer (WDM) was used to enable the simultaneous operation of two lasers at 1.49 μm (OH) and 1.39 μm (H2O, temperature), allowing for correction of water interference. OH concentrations were determined using both WMS and direct absorption spectroscopy (DAS), and the results were evaluated through comparison with CHEMKIN simulations. The proposed dual-laser system demonstrated reliable and interference-corrected quantification of OH radicals in methane (CH4)/air premixed flames over a range of equivalence ratios. Comparisons with thermocouple-based temperature measurements and CHEMKIN-predicted species concentrations confirmed the reliability of the proposed technique. This study highlights the robustness and applicability of WMS-based OH diagnostics for combustion monitoring and demonstrates the potential for future implementation in industrial burner systems.

EXPRESS:用波长调制光谱法对甲烷-空气火焰中羟基自由基进行定量诊断并校正水光谱干扰。
化石燃料燃烧产生的废气严重加剧了空气污染和气候变化,因此需要进行有效的燃烧诊断。OH自由基是火焰行为的关键指标;然而,传统的激光诱导荧光(LIF)技术由于其复杂性而不适合工业监测。在本研究中,波长调制光谱(WMS)采用波长为1.49 μm的近红外激光测量OH自由基浓度,并对H2O的光谱干扰进行了校正。采用波分复用器(WDM)实现了两个波长分别为1.49 μm (OH)和1.39 μm (H2O,温度)的激光器同时工作,从而实现了对水干扰的校正。使用WMS和直接吸收光谱(DAS)测定OH浓度,并通过与CHEMKIN模拟的比较对结果进行评估。所提出的双激光系统在一定的当量比范围内证明了甲烷(CH4)/空气预混火焰中OH自由基的可靠定量和干涉校正。与基于热电偶的温度测量和chemkin预测的物种浓度的比较证实了所提出技术的可靠性。这项研究强调了基于wms的OH诊断在燃烧监测中的稳健性和适用性,并展示了未来在工业燃烧器系统中实施的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Applied Spectroscopy
Applied Spectroscopy 工程技术-光谱学
CiteScore
6.60
自引率
5.70%
发文量
139
审稿时长
3.5 months
期刊介绍: Applied Spectroscopy is one of the world''s leading spectroscopy journals, publishing high-quality peer-reviewed articles, both fundamental and applied, covering all aspects of spectroscopy. Established in 1951, the journal is owned by the Society for Applied Spectroscopy and is published monthly. The journal is dedicated to fulfilling the mission of the Society to “…advance and disseminate knowledge and information concerning the art and science of spectroscopy and other allied sciences.”
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书