Dosimetric robustness of urethra sparing in ultrahypofractionated prostate SBRT using catheter-based motion tracking.

IF 2.8 3区 医学 Q3 ONCOLOGY
Strahlentherapie und Onkologie Pub Date : 2026-08-01 Epub Date: 2026-05-22 DOI:10.1007/s00066-026-02547-8
J Berchtold, M Schichl, N Annon-Eberharter, I M Messner, C Gaisberger, F Röder, F Wolf
{"title":"Dosimetric robustness of urethra sparing in ultrahypofractionated prostate SBRT using catheter-based motion tracking.","authors":"J Berchtold, M Schichl, N Annon-Eberharter, I M Messner, C Gaisberger, F Röder, F Wolf","doi":"10.1007/s00066-026-02547-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In ultrahypofractionated prostate stereotactic body radiation therapy (SBRT), genitourinary toxicity is the primary concern. Urethra sparing is a strategy to mitigate potential negative effects of higher single doses to the urethra and bladder neck. We report on the dosimetric robustness of urethra sparing using a catheter-based real-time monitoring device to track both interfractional variability and intrafractional motion.</p><p><strong>Methods: </strong>In 12 patients undergoing prostate ultrahypofractionated radiotherapy (UHFX), intrafractional prostate motion was monitored using a HypoCath catheter (Micropos Medical™, Gothenburg, Sweden), enabling urethra contouring on the planning CT and cone-beam (CB)CT images used for image-guided radiation therapy (IGRT). Dose coverage of both the urethra and the prostate clinical target volume (CTV) was calculated and compared between the planning CT and matched CBCTs. In addition, prostate motion was simulated and the cumulative dose coverage of prostate and urethra was calculated as a function of time.</p><p><strong>Results: </strong>The deviation between the planned and delivered urethral dose strongly correlated with elapsed time. Variations in the urethral curvature between planning CT and CBCT had only a minimal effect on the dose distribution. The combined effects of deviations in the urethral shape and prostate movement resulted in a mean dose deviation of 76 cGy for the urethral D1 of all fractions and patients. The patient who experienced the greatest prostate motion showed an increase in urethral D1 of 1.94 Gy (+5.2%).</p><p><strong>Conclusion: </strong>Urethra sparing is feasible and only marginally impaired by variations in urethral shape but is sensitive to longer treatment durations due to intrafractional movement. Direct visualization of the urethra is not essential for IGRT, but intrafractional motion control is recommended.</p>","PeriodicalId":21998,"journal":{"name":"Strahlentherapie und Onkologie","volume":" ","pages":"882-887"},"PeriodicalIF":2.8000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13391749/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strahlentherapie und Onkologie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00066-026-02547-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: In ultrahypofractionated prostate stereotactic body radiation therapy (SBRT), genitourinary toxicity is the primary concern. Urethra sparing is a strategy to mitigate potential negative effects of higher single doses to the urethra and bladder neck. We report on the dosimetric robustness of urethra sparing using a catheter-based real-time monitoring device to track both interfractional variability and intrafractional motion.

Methods: In 12 patients undergoing prostate ultrahypofractionated radiotherapy (UHFX), intrafractional prostate motion was monitored using a HypoCath catheter (Micropos Medical™, Gothenburg, Sweden), enabling urethra contouring on the planning CT and cone-beam (CB)CT images used for image-guided radiation therapy (IGRT). Dose coverage of both the urethra and the prostate clinical target volume (CTV) was calculated and compared between the planning CT and matched CBCTs. In addition, prostate motion was simulated and the cumulative dose coverage of prostate and urethra was calculated as a function of time.

Results: The deviation between the planned and delivered urethral dose strongly correlated with elapsed time. Variations in the urethral curvature between planning CT and CBCT had only a minimal effect on the dose distribution. The combined effects of deviations in the urethral shape and prostate movement resulted in a mean dose deviation of 76 cGy for the urethral D1 of all fractions and patients. The patient who experienced the greatest prostate motion showed an increase in urethral D1 of 1.94 Gy (+5.2%).

Conclusion: Urethra sparing is feasible and only marginally impaired by variations in urethral shape but is sensitive to longer treatment durations due to intrafractional movement. Direct visualization of the urethra is not essential for IGRT, but intrafractional motion control is recommended.

基于导管运动跟踪的前列腺超微分割SBRT中尿道保留的剂量学稳健性。
目的:在超低分割前列腺立体定向放射治疗(SBRT)中,泌尿生殖系统毒性是主要关注的问题。尿道保留是一种减轻高单次剂量对尿道和膀胱颈部潜在负面影响的策略。我们报告了使用基于导管的实时监测设备来跟踪尿道间隔变异性和尿道内运动的剂量学稳健性。方法:在12例接受前列腺超低分割放疗(UHFX)的患者中,使用HypoCath导管(Micropos Medical™,Gothenburg, Sweden)监测术中前列腺运动,使尿道轮廓在计划CT和锥形束CT图像上用于图像引导放射治疗(IGRT)。计算并比较计划CT与匹配cbct对尿道和前列腺临床靶体积(CTV)的剂量覆盖率。此外,模拟前列腺运动,计算前列腺和尿道的累积剂量覆盖率作为时间的函数。结果:计划给药剂量与实际给药剂量的偏差与时间密切相关。尿道曲度在计划CT和CBCT之间的变化对剂量分布的影响很小。尿道形状偏差和前列腺运动的共同作用导致各部位和患者尿道D1的平均剂量偏差为76 cGy。前列腺运动最剧烈的患者尿道D1升高1.94 Gy(+5.2%)。结论:尿道保留是可行的,仅受尿道形状变化的轻微损害,但对因尿道内运动而延长的治疗时间敏感。在IGRT中,直接观察尿道并不是必需的,但建议进行术中运动控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.70
自引率
12.90%
发文量
141
审稿时长
3-8 weeks
期刊介绍: Strahlentherapie und Onkologie, published monthly, is a scientific journal that covers all aspects of oncology with focus on radiooncology, radiation biology and radiation physics. The articles are not only of interest to radiooncologists but to all physicians interested in oncology, to radiation biologists and radiation physicists. The journal publishes original articles, review articles and case studies that are peer-reviewed. It includes scientific short communications as well as a literature review with annotated articles that inform the reader on new developments in the various disciplines concerned and hence allow for a sound overview on the latest results in radiooncology research. Founded in 1912, Strahlentherapie und Onkologie is the oldest oncological journal in the world. Today, contributions are published in English and German. All articles have English summaries and legends. The journal is the official publication of several scientific radiooncological societies and publishes the relevant communications of these societies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书