Automated echocardiographic detection of mitral valve prolapse and mitral regurgitation with video-based artificial intelligence algorithms.

IF 4.4 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
European heart journal. Digital health Pub Date : 2026-04-16 eCollection Date: 2026-06-01 DOI:10.1093/ehjdh/ztag061
Minhaj U Ansari, Joshua P Barrios, Lionel Tastet, Rohit Jhawar, Luca Cristin, Amy Rich, Dwight Bibby, Qizhi Fang, Farzin Arya, Valentina Crudo, Thuy Nguyen, Dipan J Shah, Francesca N Delling, Geoffrey H Tison
{"title":"Automated echocardiographic detection of mitral valve prolapse and mitral regurgitation with video-based artificial intelligence algorithms.","authors":"Minhaj U Ansari, Joshua P Barrios, Lionel Tastet, Rohit Jhawar, Luca Cristin, Amy Rich, Dwight Bibby, Qizhi Fang, Farzin Arya, Valentina Crudo, Thuy Nguyen, Dipan J Shah, Francesca N Delling, Geoffrey H Tison","doi":"10.1093/ehjdh/ztag061","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>We aimed to develop and evaluate fully automated artificial intelligence (AI) system for detection of mitral valve prolapse (MVP) and mitral regurgitation (MR) from echocardiographic studies.</p><p><strong>Methods and results: </strong>We used a dataset of 24 869 echocardiographic studies from the University of California San Francisco (UCSF) to train a multi-view deep neural network (DNN) to detect MVP using apical four-chamber, two-chamber, and parasternal long-axis views. A separate dataset of 27 906 studies from UCSF was used to train a second multi-view DNN model to detect moderate-to-severe or severe MR using colour Doppler in the same views. External validation was performed on echocardiographic MVP videos from Houston Methodist Hospital. The DNN model for MVP detection achieved an area under the receiver operating characteristic curve (AUC) of 0.917 [95% confidence interval (CI): 0.899-0.934], with stronger performance in those with mitral annular disjunction (MAD) or bileaflet MVP. External validation for MVP detection in a geographically and demographically distinct population yielded an AUC of 0.835 (95% CI: 0.803-0.869). The DNN for detection of moderate-to-severe or severe MR in patients with concurrent MVP achieved an AUC of 0.877 (95% CI: 0.805-0.939).</p><p><strong>Conclusion: </strong>Artificial intelligence algorithms can perform automatic detection of MVP and clinically significant MR from echocardiogram studies with high performance. The MVP DNN performed particularly well for more severe MVP phenotypes such as MAD or bileaflet MVP. These algorithms could provide a novel approach for automated, accurate, and rapid diagnosis of MVP and its common clinical sequelae across institutions.</p>","PeriodicalId":72965,"journal":{"name":"European heart journal. Digital health","volume":"7 5","pages":"ztag061"},"PeriodicalIF":4.4000,"publicationDate":"2026-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13184616/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European heart journal. Digital health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjdh/ztag061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: We aimed to develop and evaluate fully automated artificial intelligence (AI) system for detection of mitral valve prolapse (MVP) and mitral regurgitation (MR) from echocardiographic studies.

Methods and results: We used a dataset of 24 869 echocardiographic studies from the University of California San Francisco (UCSF) to train a multi-view deep neural network (DNN) to detect MVP using apical four-chamber, two-chamber, and parasternal long-axis views. A separate dataset of 27 906 studies from UCSF was used to train a second multi-view DNN model to detect moderate-to-severe or severe MR using colour Doppler in the same views. External validation was performed on echocardiographic MVP videos from Houston Methodist Hospital. The DNN model for MVP detection achieved an area under the receiver operating characteristic curve (AUC) of 0.917 [95% confidence interval (CI): 0.899-0.934], with stronger performance in those with mitral annular disjunction (MAD) or bileaflet MVP. External validation for MVP detection in a geographically and demographically distinct population yielded an AUC of 0.835 (95% CI: 0.803-0.869). The DNN for detection of moderate-to-severe or severe MR in patients with concurrent MVP achieved an AUC of 0.877 (95% CI: 0.805-0.939).

Conclusion: Artificial intelligence algorithms can perform automatic detection of MVP and clinically significant MR from echocardiogram studies with high performance. The MVP DNN performed particularly well for more severe MVP phenotypes such as MAD or bileaflet MVP. These algorithms could provide a novel approach for automated, accurate, and rapid diagnosis of MVP and its common clinical sequelae across institutions.

基于视频的人工智能算法自动超声心动图检测二尖瓣脱垂和二尖瓣反流。
目的:我们旨在开发和评估全自动人工智能(AI)系统,用于检测超声心动图研究中的二尖瓣脱垂(MVP)和二尖瓣反流(MR)。方法和结果:我们使用来自加州大学旧金山分校(UCSF)的24869个超声心动图研究数据集来训练一个多视图深度神经网络(DNN),以使用四室、两室和胸骨旁长轴视图检测MVP。来自UCSF的27906项研究的单独数据集用于训练第二个多视图DNN模型,以在相同视图中使用彩色多普勒检测中度至重度或重度MR。对休斯顿卫理公会医院的超声心动图MVP视频进行外部验证。DNN模型用于MVP检测的受试者工作特征曲线下面积(AUC)为0.917[95%置信区间(CI): 0.899-0.934],对二尖瓣环状分离(MAD)或双小瓣膜MVP的检测效果更佳。在地理和人口统计学上不同的人群中进行MVP检测的外部验证的AUC为0.835 (95% CI: 0.803-0.869)。并发MVP患者中至重度或重度MR的DNN检测AUC为0.877 (95% CI: 0.805-0.939)。结论:人工智能算法可以高效地自动检测超声心动图研究中的MVP和临床意义MR。MVP DNN在更严重的MVP表型(如MAD或双小叶MVP)中表现特别好。这些算法可以为自动化、准确和快速诊断MVP及其常见的临床后遗症提供一种新的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书