Influence of rubbing during etching on surface roughness and interfacial characteristics of intact enamel.

IF 2 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Moana Biedermann, Iosif Sifakakis, Spiros Zinelis, George Eliades, Theodore Eliades, Raphael Patcas
{"title":"Influence of rubbing during etching on surface roughness and interfacial characteristics of intact enamel.","authors":"Moana Biedermann, Iosif Sifakakis, Spiros Zinelis, George Eliades, Theodore Eliades, Raphael Patcas","doi":"10.1111/eos.70108","DOIUrl":null,"url":null,"abstract":"<p><p>Rubbing phosphoric acid during etching has been shown to improve surface roughness in prepared enamel. This study aimed to compare intact enamel's surface roughness and resin tag lengths after etching with and without rubbing. Extracted sound third molars were used for testing, mesially for conventional and distally for dynamic (rubbing) etchant application. All surfaces were etched for 20 s with 37% phosphoric acid etchant and rinsed with water for 10 s. Optical profilometry and high-vacuum scanning electron microscopy (HV-SEM) were used for enamel surface assessment and evaluation of the infiltrating capacity of a bonding resin into enamel. Statistical analyses were done by a paired t-test. The obtained results demonstrated that rubbing the acid agent during etching showed no statistically significant increase in enamel surface roughness. In both groups, texture aspect ratio (Str) values were close to 1 (standard Str = 0.86, rubbing Str = 0.90), indicating that both surfaces can be considered isotropic. HV-SEM images showed a more typical etching pattern after rubbing, but with insignificant differences in the height of the resin tags. It can be concluded that rubbing during the etching of intact enamel results in a similar surface roughness and resin-enamel interface compared with the conventional etching technique. This stands in contrast to the reported improvement achieved on prepared enamel.</p>","PeriodicalId":11983,"journal":{"name":"European Journal of Oral Sciences","volume":" ","pages":"e70108"},"PeriodicalIF":2.0000,"publicationDate":"2026-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/eos.70108","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Rubbing phosphoric acid during etching has been shown to improve surface roughness in prepared enamel. This study aimed to compare intact enamel's surface roughness and resin tag lengths after etching with and without rubbing. Extracted sound third molars were used for testing, mesially for conventional and distally for dynamic (rubbing) etchant application. All surfaces were etched for 20 s with 37% phosphoric acid etchant and rinsed with water for 10 s. Optical profilometry and high-vacuum scanning electron microscopy (HV-SEM) were used for enamel surface assessment and evaluation of the infiltrating capacity of a bonding resin into enamel. Statistical analyses were done by a paired t-test. The obtained results demonstrated that rubbing the acid agent during etching showed no statistically significant increase in enamel surface roughness. In both groups, texture aspect ratio (Str) values were close to 1 (standard Str = 0.86, rubbing Str = 0.90), indicating that both surfaces can be considered isotropic. HV-SEM images showed a more typical etching pattern after rubbing, but with insignificant differences in the height of the resin tags. It can be concluded that rubbing during the etching of intact enamel results in a similar surface roughness and resin-enamel interface compared with the conventional etching technique. This stands in contrast to the reported improvement achieved on prepared enamel.

蚀刻过程中摩擦对完整牙釉质表面粗糙度和界面特性的影响。
在蚀刻过程中摩擦磷酸可以改善制备的牙釉质的表面粗糙度。本研究的目的是比较完整的牙釉质表面粗糙度和树脂标签长度后蚀刻与不摩擦。提取完好的第三磨牙用于测试,主要用于常规,远端用于动态(摩擦)蚀刻应用。所有表面用37%磷酸蚀刻剂蚀刻20 s,用水冲洗10 s。采用光学轮廓术和高真空扫描电镜(HV-SEM)对牙釉质表面进行了评价,并对粘接树脂对牙釉质的渗透能力进行了评价。统计分析采用配对t检验。结果表明,在蚀刻过程中磨擦酸剂对牙釉质表面粗糙度的影响无统计学意义。在两组中,纹理纵横比(Str)值都接近于1(标准Str = 0.86,摩擦Str = 0.90),表明两组表面都可以认为是各向同性的。摩擦后的HV-SEM图像显示出更典型的蚀刻模式,但树脂标签的高度差异不显著。结果表明,在完整牙釉质的蚀刻过程中,与传统的蚀刻工艺相比,摩擦可以获得相似的表面粗糙度和树脂-牙釉质界面。这与报道的在制备的牙釉质上取得的改善形成对比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Journal of Oral Sciences
European Journal of Oral Sciences 医学-牙科与口腔外科
CiteScore
3.50
自引率
5.30%
发文量
61
审稿时长
2 months
期刊介绍: The European Journal of Oral Sciences is an international journal which publishes original research papers within clinical dentistry, on all basic science aspects of structure, chemistry, developmental biology, physiology and pathology of relevant tissues, as well as on microbiology, biomaterials and the behavioural sciences as they relate to dentistry. In general, analytical studies are preferred to descriptive ones. Reviews, Short Communications and Letters to the Editor will also be considered for publication. The journal is published bimonthly.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书