Beyond iodine-131: protective effect of stable iodine for all iodine isotopes of radiological concern.

IF 1.7 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
D Broggio, N Delagrange, P Teles, V Berkovskyy
{"title":"Beyond iodine-131: protective effect of stable iodine for all iodine isotopes of radiological concern.","authors":"D Broggio, N Delagrange, P Teles, V Berkovskyy","doi":"10.1088/1361-6498/ae6f27","DOIUrl":null,"url":null,"abstract":"<p><p>Administering stable iodine is an effective strategy to protect the thyroid in case of an accidental release of radioiodines.<sup>131</sup>I is the most concerning iodine isotope due to its amount in the reactor vessel and its relatively long half-life. These factors result in<sup>131</sup>I dominance in the total thyroid dose, and many studies focus on this isotope. The protective effect (PE) of stable iodine for other iodine isotopes is not well documented, and this study examines<sup>132</sup>I and nine other isotopes with longer half-lives. The predicted trend in PE is estimated using a biokinetic toy model of the blocking effect. Then, the Zanzonico and Beckermodel (2000<i>Health Phys.</i><b>78</b>660-7) is implemented for the inhalation of aerosol type F with an AMAD of 1<i>μ</i>m. The PE for administration of 130 mg KI is tabulated for administration time between 96 h prior to the intake and 48 h after the intake for 10 isotopes including<sup>131</sup>I. It has been found that, regardless of the timing of stable iodine administration, the PE is similar for<sup>124</sup>I (<i>T</i><sub>1/2</sub>∼ 4.2 d),<sup>131</sup>I (<i>T</i><sub>1/2</sub>∼ 8 d), and other isotopes with longer half-lives. For isotopes with shorter half-lives, the relative PE (normalised to the respective<sup>131</sup>I values) depends on the timing of stable iodine administration and the isotopes' half-life. If stable iodine is taken after intake, the shorter the half-life the lower the PE. If stable iodine is taken before intake the opposite applies. For stable iodine administration 48 h before the intake the PE is 93% for<sup>132</sup>I and 73% for<sup>131</sup>I, for administration 24 h before the intake these values are 99 and 95%. Taken 6 h after the intake the PE is only 9% for<sup>132</sup>I but still 51% for<sup>131</sup>I. The results obtained here could be considered for emergency planning and preparedness as well as communication with the public in case of accidental radioiodine release.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ae6f27","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Administering stable iodine is an effective strategy to protect the thyroid in case of an accidental release of radioiodines.131I is the most concerning iodine isotope due to its amount in the reactor vessel and its relatively long half-life. These factors result in131I dominance in the total thyroid dose, and many studies focus on this isotope. The protective effect (PE) of stable iodine for other iodine isotopes is not well documented, and this study examines132I and nine other isotopes with longer half-lives. The predicted trend in PE is estimated using a biokinetic toy model of the blocking effect. Then, the Zanzonico and Beckermodel (2000Health Phys.78660-7) is implemented for the inhalation of aerosol type F with an AMAD of 1μm. The PE for administration of 130 mg KI is tabulated for administration time between 96 h prior to the intake and 48 h after the intake for 10 isotopes including131I. It has been found that, regardless of the timing of stable iodine administration, the PE is similar for124I (T1/2∼ 4.2 d),131I (T1/2∼ 8 d), and other isotopes with longer half-lives. For isotopes with shorter half-lives, the relative PE (normalised to the respective131I values) depends on the timing of stable iodine administration and the isotopes' half-life. If stable iodine is taken after intake, the shorter the half-life the lower the PE. If stable iodine is taken before intake the opposite applies. For stable iodine administration 48 h before the intake the PE is 93% for132I and 73% for131I, for administration 24 h before the intake these values are 99 and 95%. Taken 6 h after the intake the PE is only 9% for132I but still 51% for131I. The results obtained here could be considered for emergency planning and preparedness as well as communication with the public in case of accidental radioiodine release.

超越碘-131:稳定碘对所有放射性关注的碘同位素的保护作用。
在放射性碘意外释放的情况下,给予稳定碘是保护甲状腺的有效策略。131I是最受关注的碘同位素,因为它在反应堆容器中的数量和相对较长的半衰期。这些因素导致131I在甲状腺总剂量中占主导地位,许多研究都集中在这个同位素上。稳定碘对其他碘同位素的保护作用没有很好的文献记载,本研究考察了132I和其他九种半衰期较长的同位素。使用阻断效应的生物动力学玩具模型估计了保护作用的预测趋势。然后,对吸入AMAD为1 μm的F型气溶胶实施Zanzonico和Becker模型(2000)。对包括131I在内的10种同位素,按摄入前96小时至摄入后48小时的给药时间,列出了130 mg KI的保护作用。研究发现,无论稳定碘给药的时间如何,124I (T1/2 ~4.2天)、131I (T1/2 ~ 8天)和其他半衰期较长的同位素的保护作用是相似的。对于半衰期较短的同位素,相对保护作用(归一化到各自的131I值)取决于稳定碘施用的时间和同位素的半衰期。如果在摄入后服用稳定碘,半衰期越短,保护作用越低。如果在摄入前服用稳定的碘,则相反。在摄入前48小时稳定服用碘,对132I的保护作用为93%,对131I的保护作用为73%,在摄入前24小时稳定服用碘,这两个值分别为99%和95%。摄入6小时后服用,对132I的保护作用只有9%,但对131I的保护作用仍然是51%。在此获得的结果可用于应急规划和准备,以及在意外放射性碘释放的情况下与公众进行沟通。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书