Functional Rehabilitation of Mandibular Defect Using CAD/CAM System.

IF 0.8 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Bulletin of Tokyo Dental College Pub Date : 2026-06-17 Epub Date: 2026-05-15 DOI:10.2209/tdcpublication.2025-0023
Fusa Maeta, Koichiro Ogami, Taiga Edono, Shuya Yoshida, Takayuki Ueda
{"title":"Functional Rehabilitation of Mandibular Defect Using CAD/CAM System.","authors":"Fusa Maeta, Koichiro Ogami, Taiga Edono, Shuya Yoshida, Takayuki Ueda","doi":"10.2209/tdcpublication.2025-0023","DOIUrl":null,"url":null,"abstract":"<p><p>This report describes a case in which a removable partial mandibular denture made of polycarbonate resin was fabricated using a computer-aided design and manufacturing (CAD/CAM) system for a patient with microstomia and trismus caused by scar contracture in the maxillofacial region after multiple tumor resections and reconstructive surgeries. The patient was an 82-year-old woman with a history of multiple oral cancer surgeries and radiotherapy. She presented with a markedly narrow oral aperture circumference (145 mm) and had no prior experience with dentures. Given the difficulty of applying conventional impression techniques in this case, impressions were obtained using unilateral stock trays and split custom trays. The denture base and artificial teeth were milled from a polycarbonate disk into a single-piece structure to create a denture with no microgaps. One month after insertion, the patient's Oral Health Impact Profile-54 score improved from 36 to 6, masticatory efficiency increased from 84 mg/dL to 131 mg/dL, and the facial scale score improved from 13/20 to 7/20. Furthermore, the smooth denture surface minimized denture plaque adhesion, aiding oral hygiene maintenance. In addition to the low water absorption and high smoothness of polycarbonate resin, integrated design achieved using CAD/CAM contributes to the prevention of denture stomatitis and oral candidiasis.</p>","PeriodicalId":45490,"journal":{"name":"Bulletin of Tokyo Dental College","volume":" ","pages":"41-49"},"PeriodicalIF":0.8000,"publicationDate":"2026-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Tokyo Dental College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2209/tdcpublication.2025-0023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/15 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This report describes a case in which a removable partial mandibular denture made of polycarbonate resin was fabricated using a computer-aided design and manufacturing (CAD/CAM) system for a patient with microstomia and trismus caused by scar contracture in the maxillofacial region after multiple tumor resections and reconstructive surgeries. The patient was an 82-year-old woman with a history of multiple oral cancer surgeries and radiotherapy. She presented with a markedly narrow oral aperture circumference (145 mm) and had no prior experience with dentures. Given the difficulty of applying conventional impression techniques in this case, impressions were obtained using unilateral stock trays and split custom trays. The denture base and artificial teeth were milled from a polycarbonate disk into a single-piece structure to create a denture with no microgaps. One month after insertion, the patient's Oral Health Impact Profile-54 score improved from 36 to 6, masticatory efficiency increased from 84 mg/dL to 131 mg/dL, and the facial scale score improved from 13/20 to 7/20. Furthermore, the smooth denture surface minimized denture plaque adhesion, aiding oral hygiene maintenance. In addition to the low water absorption and high smoothness of polycarbonate resin, integrated design achieved using CAD/CAM contributes to the prevention of denture stomatitis and oral candidiasis.

应用CAD/CAM系统进行下颌骨缺损功能修复。
本报告描述了一个使用计算机辅助设计和制造(CAD/CAM)系统为颌面部区域瘢痕挛缩引起的小口和咬牙症患者在多次肿瘤切除和重建手术后,使用聚碳酸酯树脂制作可移动下颌部分义齿的病例。患者为82岁女性,有多次口腔癌手术和放疗史。她表现出明显狭窄的口孔周长(145毫米),并且没有使用假牙的经验。考虑到在这种情况下应用传统印象技术的困难,使用单边库存托盘和分裂定制托盘获得印象。义齿基托和人工牙由聚碳酸酯圆盘磨成单片结构,制成无微间隙义齿。插入后1个月,患者的口腔健康影响评分从36分提高到6分,咀嚼效率从84 mg/dL提高到131 mg/dL,面部评分从13/20提高到7/20。此外,光滑的义齿表面减少了义齿菌斑的粘附,有助于口腔卫生的维护。除了聚碳酸酯树脂吸水率低、平滑度高外,采用CAD/CAM实现的一体化设计有助于预防义齿口炎和口腔念珠菌病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bulletin of Tokyo Dental College
Bulletin of Tokyo Dental College DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: The bulletin of Tokyo Dental collegue is principally for the publication of original contributions to multidisciplinary research in dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书