{"title":"Eye lens dose distribution in neonatal head CT: an analysis of the scanning conditions and CTDIvol limitations.","authors":"Tatsuhiro Gotanda, Takuya Akagawa, Tomoyuki Hasuo, Shinnosuke Nishihara, Kohsei Matsuura, Yasuyuki Kawaji, Hidetoshi Yatake, Shinya Imai, Rumi Gotanda, Toshizo Katsuda","doi":"10.1093/rpd/ncag046","DOIUrl":null,"url":null,"abstract":"<p><p>Despite neonatal radiosensitivity, accurate lens dose assessments in computed tomography (CT) are lacking. We assessed the neonatal head CT eye lens dose under various scanning conditions, including vertical table displacement and organ-based exposure modulation (OEM), using the GAFCHROMIC LD-V1 (LD-V1), which can measure two-dimensional dose distributions, and we evaluated the limitations of conventional dose indices. The lens dose decreased with increasing distance from the isocentre for the Canon 320. Whereas, for the Canon 80 and Siemens, the dose peaked at +25 mm and then decreased. For the OEM, the dose reduction effect decreased at 30°. The CT dose index volume remained consistent. Spatially resolved dosimetry using the LD-V1 reveals beam overlap and positioning-related dose anomalies that cannot be captured by point dosimeters or conventional indices. The LD-V1 can effectively evaluate superficial dose distributions and guide dose optimization in neonatal imaging.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":"1096-1107"},"PeriodicalIF":0.8000,"publicationDate":"2026-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncag046","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Despite neonatal radiosensitivity, accurate lens dose assessments in computed tomography (CT) are lacking. We assessed the neonatal head CT eye lens dose under various scanning conditions, including vertical table displacement and organ-based exposure modulation (OEM), using the GAFCHROMIC LD-V1 (LD-V1), which can measure two-dimensional dose distributions, and we evaluated the limitations of conventional dose indices. The lens dose decreased with increasing distance from the isocentre for the Canon 320. Whereas, for the Canon 80 and Siemens, the dose peaked at +25 mm and then decreased. For the OEM, the dose reduction effect decreased at 30°. The CT dose index volume remained consistent. Spatially resolved dosimetry using the LD-V1 reveals beam overlap and positioning-related dose anomalies that cannot be captured by point dosimeters or conventional indices. The LD-V1 can effectively evaluate superficial dose distributions and guide dose optimization in neonatal imaging.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.