Design of a steam thermal ablation system for liver tumors and its efficacy evaluation based on fluorescence imaging.

IF 1.8 4区 医学 Q2 SURGERY
Jingqi Song, Wei Wei, Haotian Wang, Kairan Wan, Zhiyu Qian, Lidong Xing, Xiaofei Jin
{"title":"Design of a steam thermal ablation system for liver tumors and its efficacy evaluation based on fluorescence imaging.","authors":"Jingqi Song, Wei Wei, Haotian Wang, Kairan Wan, Zhiyu Qian, Lidong Xing, Xiaofei Jin","doi":"10.1080/13645706.2026.2666590","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>At present, traditional minimally invasive thermal ablation technologies are all derived from electromagnetic radiation energy generated by high-frequency, high-energy physical sources. Consequently, they all share common issues, such as poor conformability, carbonization, difficulty controlling temperature, and electromagnetic radiation.</p><p><strong>Methods: </strong>This paper proposes a steam thermal ablation (STA) technology that utilizes the internal energy of saturated steam to replace traditional electromagnetic radiation-based energy sources. Using a self-built, minimally invasive steam thermal ablation precision treatment system for liver tumors and a steam ablation needle designed via COMSOL simulation, ex vivo pig liver experiments were conducted. Based on STA characteristics, a real-time monitoring scheme for the ablation boundary has been proposed using fluorescence imaging.</p><p><strong>Results: </strong>The results of STA are characterized by a maximal ablation axis ratio (short diameter/long diameter) and the absence of carbonization. The fluorescence-based monitoring effectively eliminated artifacts and radiation constraints typical of ultrasound or CT-guided procedures.</p><p><strong>Conclusions: </strong>Steam thermal ablation (STA) technology offers a novel thermal ablation method, featuring good conformability and no carbonization. Combined with real-time fluorescence imaging monitoring, it provides a feasible solution for the limitations of traditional minimally invasive thermal ablation techniques.</p>","PeriodicalId":18537,"journal":{"name":"Minimally Invasive Therapy & Allied Technologies","volume":" ","pages":"392-403"},"PeriodicalIF":1.8000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Therapy & Allied Technologies","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/13645706.2026.2666590","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: At present, traditional minimally invasive thermal ablation technologies are all derived from electromagnetic radiation energy generated by high-frequency, high-energy physical sources. Consequently, they all share common issues, such as poor conformability, carbonization, difficulty controlling temperature, and electromagnetic radiation.

Methods: This paper proposes a steam thermal ablation (STA) technology that utilizes the internal energy of saturated steam to replace traditional electromagnetic radiation-based energy sources. Using a self-built, minimally invasive steam thermal ablation precision treatment system for liver tumors and a steam ablation needle designed via COMSOL simulation, ex vivo pig liver experiments were conducted. Based on STA characteristics, a real-time monitoring scheme for the ablation boundary has been proposed using fluorescence imaging.

Results: The results of STA are characterized by a maximal ablation axis ratio (short diameter/long diameter) and the absence of carbonization. The fluorescence-based monitoring effectively eliminated artifacts and radiation constraints typical of ultrasound or CT-guided procedures.

Conclusions: Steam thermal ablation (STA) technology offers a novel thermal ablation method, featuring good conformability and no carbonization. Combined with real-time fluorescence imaging monitoring, it provides a feasible solution for the limitations of traditional minimally invasive thermal ablation techniques.

基于荧光成像的肝肿瘤蒸汽热消融系统设计及疗效评价。
背景:目前,传统的微创热消融技术均来源于高频高能物理源产生的电磁辐射能。因此,它们都有共同的问题,如相容性差、碳化、难以控制温度和电磁辐射。方法:提出了一种利用饱和蒸汽内能替代传统电磁辐射能源的蒸汽热烧蚀(STA)技术。利用自行研制的肝脏肿瘤微创蒸汽热消融精密治疗系统和COMSOL模拟设计的蒸汽消融针,进行了猪肝离体实验。基于STA的特点,提出了一种利用荧光成像技术实时监测烧蚀边界的方案。结果:STA具有最大消融轴比(短径/长径)和无碳化的特点。基于荧光的监测有效地消除了超声或ct引导程序的典型伪影和辐射限制。结论:蒸汽热烧蚀(STA)技术提供了一种新型的热烧蚀方法,具有一致性好、无碳化的特点。结合实时荧光成像监测,为传统微创热消融技术的局限性提供了可行的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
5.90%
发文量
39
审稿时长
6-12 weeks
期刊介绍: Minimally Invasive Therapy and Allied Technologies (MITAT) is an international forum for endoscopic surgeons, interventional radiologists and industrial instrument manufacturers. It is the official journal of the Society for Medical Innovation and Technology (SMIT) whose membership includes representatives from a broad spectrum of medical specialities, instrument manufacturing and research. The journal brings the latest developments and innovations in minimally invasive therapy to its readers. What makes Minimally Invasive Therapy and Allied Technologies unique is that we publish one or two special issues each year, which are devoted to a specific theme. Key topics covered by the journal include: interventional radiology, endoscopic surgery, imaging technology, manipulators and robotics for surgery and education and training for MIS.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书