Comparison of Effective Optical Zone, Lenticule Decentration, and Corneal Aberrations Following KLEx Extraction Between the VisuMax 800 and VisuMax 500.
{"title":"Comparison of Effective Optical Zone, Lenticule Decentration, and Corneal Aberrations Following KLEx Extraction Between the VisuMax 800 and VisuMax 500.","authors":"Yishan Qian, Junjie Yu, Jing Zhao, Xingtao Zhou","doi":"10.3928/1081597X-20260224-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the effective optical zone (EOZ), extent of lenticule decentration, and corneal higher order aberrations (HOAs) after keratorefractive lenticule extraction (KLEx) using the VisuMax 800 and 500 (Carl Zeiss Meditec AG).</p><p><strong>Methods: </strong>This was a prospective, matched case-control study controlled for programmed sphere (PS: ±0.25 diopters [D]), cylinder (PC: ±0.25 D), and optical zone (±0.1 mm). The EOZ and decentration values were obtained from the tangential topography difference map. The refractive outcomes and corneal HOAs were compared between the two platforms at the 3-month postoperative visit.</p><p><strong>Results: </strong>A total of 95 right eyes of 95 patients who underwent KLEx using the VisuMax 800 and 95 patients using the VisuMax 500 were included. Both platforms are effective and safe for the treatment of myopia and astigmatism. No significant difference was found in the percentage reduction of EOZ between the two platforms (16.52 ± 4.53% vs 16.42 ± 4.60%, <i>P</i> = .637). Multiple linear regression revealed that, for both platforms, PS and mean keratometry were negatively correlated with the percentage reduction in EOZ, whereas PC was positively correlated with the percentage reduction in EOZ. The absolute values of the vertical decentration were significantly lower for the VisuMax 800 (0.14 ± 0.10 vs 0.21 ± 0.14 mm, <i>P</i> < .001). No significant differences in postoperative total HOAs, horizontal and vertical coma, or spherical aberration were found between the two platforms (<i>P</i> > .05).</p><p><strong>Conclusions: </strong>Both platforms achieved good and comparable refractive, EOZ, and HOAs outcomes. The VisuMax 800 demonstrated higher centration accuracy.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"42 5","pages":"e453-e460"},"PeriodicalIF":2.9000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20260224-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To compare the effective optical zone (EOZ), extent of lenticule decentration, and corneal higher order aberrations (HOAs) after keratorefractive lenticule extraction (KLEx) using the VisuMax 800 and 500 (Carl Zeiss Meditec AG).
Methods: This was a prospective, matched case-control study controlled for programmed sphere (PS: ±0.25 diopters [D]), cylinder (PC: ±0.25 D), and optical zone (±0.1 mm). The EOZ and decentration values were obtained from the tangential topography difference map. The refractive outcomes and corneal HOAs were compared between the two platforms at the 3-month postoperative visit.
Results: A total of 95 right eyes of 95 patients who underwent KLEx using the VisuMax 800 and 95 patients using the VisuMax 500 were included. Both platforms are effective and safe for the treatment of myopia and astigmatism. No significant difference was found in the percentage reduction of EOZ between the two platforms (16.52 ± 4.53% vs 16.42 ± 4.60%, P = .637). Multiple linear regression revealed that, for both platforms, PS and mean keratometry were negatively correlated with the percentage reduction in EOZ, whereas PC was positively correlated with the percentage reduction in EOZ. The absolute values of the vertical decentration were significantly lower for the VisuMax 800 (0.14 ± 0.10 vs 0.21 ± 0.14 mm, P < .001). No significant differences in postoperative total HOAs, horizontal and vertical coma, or spherical aberration were found between the two platforms (P > .05).
Conclusions: Both platforms achieved good and comparable refractive, EOZ, and HOAs outcomes. The VisuMax 800 demonstrated higher centration accuracy.
期刊介绍:
The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as:
• Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics”
• Supplemental videos and materials available for many articles
• Access to current articles, as well as several years of archived content
• Articles posted online just 2 months after acceptance.