Multi-information fusion of characteristic spectral lines for enhanced quantitative accuracy in laser-induced breakdown spectroscopy

IF 3.3 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Yutao Huang, Yuan Liu, Xiaomei Lin, Jingjun Lin, Jiangfei Yang, Aiguo Tan, Keke Ma, Hongxiang Zhang and Nanqi Ruan
{"title":"Multi-information fusion of characteristic spectral lines for enhanced quantitative accuracy in laser-induced breakdown spectroscopy","authors":"Yutao Huang, Yuan Liu, Xiaomei Lin, Jingjun Lin, Jiangfei Yang, Aiguo Tan, Keke Ma, Hongxiang Zhang and Nanqi Ruan","doi":"10.1039/D6JA00043F","DOIUrl":null,"url":null,"abstract":"<p >When employing Laser-Induced Breakdown Spectroscopy (LIBS) for the quantitative analysis of heavy metal elements in soil, conventional quantitative analysis methods typically rely solely on single spectral line intensity information. The quantitative results are prone to fluctuations in excitation source energy, environmental parameter variations, and self-absorption effects, resulting in relatively low detection accuracy. To overcome these limitations and improve the accuracy of quantitative analysis, this study first introduced a decision filter based on the Median Absolute Deviation (MAD) algorithm for data processing, thereby improving data reliability. Subsequently, by analyzing trends in peak intensity, Spectral Peak Area (SPA), and full width at half maximum (FWHM) of spectral lines as a function of elemental concentrations, and evaluating the linear fitting performance of these three distinct types of information, the relative advantages of various spectral line information in quantitative analysis were assessed based on excitation principles. Building on this, a nonlinear Support Vector Regression (SVR) model was employed to integrate intensity, SPA, and FWHM from characteristic spectral lines. This integration facilitated information complementarity, thereby improving the accuracy of quantitative analysis. Experimental results demonstrated that the nonlinear regression model, incorporating multiple spectral line information, significantly enhanced quantitative analysis accuracy compared with linear regression models utilizing only single types of spectral line information. Specifically, the root mean square error (RMSE) for chromium (Cr) and lead (Pb) was 0.036 wt% and 0.026 wt%, respectively, with an average relative error (ARE) of 8.624% and 5.733%. The fitting coefficients (<em>R</em><small><sup>2</sup></small>) exceeded 0.98 for both elements. By integrating the multi-dimensional information of characteristic spectral lines and employing a nonlinear SVR model for calibration, this study effectively overcomes the limitations inherent in traditional quantitative analysis relying on single-peak information. This approach significantly enhances the accuracy and robustness of LIBS technology for quantitative detection of heavy metals in soil, providing an effective solution for high-accuracy, multi-information-fused LIBS quantitative analysis in complex environments.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 5","pages":" 1883-1893"},"PeriodicalIF":3.3000,"publicationDate":"2026-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d6ja00043f","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

When employing Laser-Induced Breakdown Spectroscopy (LIBS) for the quantitative analysis of heavy metal elements in soil, conventional quantitative analysis methods typically rely solely on single spectral line intensity information. The quantitative results are prone to fluctuations in excitation source energy, environmental parameter variations, and self-absorption effects, resulting in relatively low detection accuracy. To overcome these limitations and improve the accuracy of quantitative analysis, this study first introduced a decision filter based on the Median Absolute Deviation (MAD) algorithm for data processing, thereby improving data reliability. Subsequently, by analyzing trends in peak intensity, Spectral Peak Area (SPA), and full width at half maximum (FWHM) of spectral lines as a function of elemental concentrations, and evaluating the linear fitting performance of these three distinct types of information, the relative advantages of various spectral line information in quantitative analysis were assessed based on excitation principles. Building on this, a nonlinear Support Vector Regression (SVR) model was employed to integrate intensity, SPA, and FWHM from characteristic spectral lines. This integration facilitated information complementarity, thereby improving the accuracy of quantitative analysis. Experimental results demonstrated that the nonlinear regression model, incorporating multiple spectral line information, significantly enhanced quantitative analysis accuracy compared with linear regression models utilizing only single types of spectral line information. Specifically, the root mean square error (RMSE) for chromium (Cr) and lead (Pb) was 0.036 wt% and 0.026 wt%, respectively, with an average relative error (ARE) of 8.624% and 5.733%. The fitting coefficients (R2) exceeded 0.98 for both elements. By integrating the multi-dimensional information of characteristic spectral lines and employing a nonlinear SVR model for calibration, this study effectively overcomes the limitations inherent in traditional quantitative analysis relying on single-peak information. This approach significantly enhances the accuracy and robustness of LIBS technology for quantitative detection of heavy metals in soil, providing an effective solution for high-accuracy, multi-information-fused LIBS quantitative analysis in complex environments.

Abstract Image

激光诱导击穿光谱中特征光谱线的多信息融合提高定量精度
在利用激光诱导击穿光谱(LIBS)对土壤中重金属元素进行定量分析时,传统的定量分析方法通常仅依赖于单线谱线强度信息。定量结果容易受激发源能量波动、环境参数变化、自吸收等影响,检测精度较低。为了克服这些局限性,提高定量分析的准确性,本研究首先引入了基于中位数绝对偏差(MAD)算法的决策滤波器对数据进行处理,从而提高了数据的可靠性。随后,通过分析谱线的峰强度、谱峰面积(SPA)和半峰全宽(FWHM)随元素浓度的变化趋势,并评价这三种不同类型信息的线性拟合性能,评价基于激发原理的各种谱线信息在定量分析中的相对优势。在此基础上,采用非线性支持向量回归(SVR)模型对特征谱线的强度、SPA和FWHM进行积分。这种整合促进了信息的互补,从而提高了定量分析的准确性。实验结果表明,与仅利用单一谱线信息的线性回归模型相比,包含多种谱线信息的非线性回归模型显著提高了定量分析的精度。其中,铬(Cr)和铅(Pb)的均方根误差(RMSE)分别为0.036 wt%和0.026 wt%,平均相对误差(ARE)分别为8.624%和5.733%。两个因素的拟合系数R2均超过0.98。本研究通过整合特征谱线的多维信息,采用非线性支持向量回归模型进行定标,有效克服了传统依赖单峰信息定量分析的局限性。该方法显著提高了LIBS技术用于土壤重金属定量检测的准确性和鲁棒性,为复杂环境下高精度、多信息融合的LIBS定量分析提供了有效解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书