Single- and dual-isotopic analysis using high-resolution continuum-source graphite-furnace molecular absorption. Strategies for data selection, processing, and modeling

IF 3.3 2区 化学 Q2 CHEMISTRY, ANALYTICAL
André L. M. de Souza, Maite Aramendía, Esperanza García-Ruiz, Flávio V. Nakadi, Javier Resano and Martín Resano
{"title":"Single- and dual-isotopic analysis using high-resolution continuum-source graphite-furnace molecular absorption. Strategies for data selection, processing, and modeling","authors":"André L. M. de Souza, Maite Aramendía, Esperanza García-Ruiz, Flávio V. Nakadi, Javier Resano and Martín Resano","doi":"10.1039/D6JA00062B","DOIUrl":null,"url":null,"abstract":"<p >This work evaluates different strategies for data processing, aiming at achieving isotopic information <em>via</em> high-resolution continuum-source graphite-furnace molecular absorption. For this purpose, two different molecules are investigated: CaF and CaCl. In the first case, only the measurement of <small><sup>44</sup></small>Ca and <small><sup>40</sup></small>Ca is pursued, whereas in the second case, isotopic variations affect both elements present in the molecule (<small><sup>44</sup></small>Ca and <small><sup>40</sup></small>Ca, but also <small><sup>37</sup></small>Cl and <small><sup>35</sup></small>Cl). Thus, two different approaches are proposed. For Ca isotopic analysis through the monitoring of CaF, the effects of selecting the number of detection pixels and the number of molecular spectra, as well as of using a regression approach for temporal data, are discussed. Overall, using three detector pixels and using this regression approach tend to produce the best results (0.5–1.0% RSD) for isotopic analysis <em>via</em> HR CS GFMAS in those situations in which the signal can be derived from two separate peaks. On the other hand, to perform simultaneous Ca and Cl isotopic analysis by monitoring CaCl, a machine-learning strategy is proposed. The performance of such a model is promising for isotopic abundances of at least 10% (median absolute percentage error of 1.21%), while the error escalates when one of the isotopes shows a lower abundance. To detect such underperforming situations in real-world settings, it is recommended to monitor the prediction uncertainty to set thresholds and flag results with poor reliability.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 5","pages":" 1951-1963"},"PeriodicalIF":3.3000,"publicationDate":"2026-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d6ja00062b?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d6ja00062b","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This work evaluates different strategies for data processing, aiming at achieving isotopic information via high-resolution continuum-source graphite-furnace molecular absorption. For this purpose, two different molecules are investigated: CaF and CaCl. In the first case, only the measurement of 44Ca and 40Ca is pursued, whereas in the second case, isotopic variations affect both elements present in the molecule (44Ca and 40Ca, but also 37Cl and 35Cl). Thus, two different approaches are proposed. For Ca isotopic analysis through the monitoring of CaF, the effects of selecting the number of detection pixels and the number of molecular spectra, as well as of using a regression approach for temporal data, are discussed. Overall, using three detector pixels and using this regression approach tend to produce the best results (0.5–1.0% RSD) for isotopic analysis via HR CS GFMAS in those situations in which the signal can be derived from two separate peaks. On the other hand, to perform simultaneous Ca and Cl isotopic analysis by monitoring CaCl, a machine-learning strategy is proposed. The performance of such a model is promising for isotopic abundances of at least 10% (median absolute percentage error of 1.21%), while the error escalates when one of the isotopes shows a lower abundance. To detect such underperforming situations in real-world settings, it is recommended to monitor the prediction uncertainty to set thresholds and flag results with poor reliability.

Abstract Image

利用高分辨率连续源石墨炉分子吸收进行单同位素和双同位素分析。数据选择、处理和建模的策略
这项工作评估了不同的数据处理策略,旨在通过高分辨率连续源石墨炉分子吸收获得同位素信息。为此,研究了两种不同的分子:CaF和CaCl。在第一种情况下,只测量44Ca和40Ca,而在第二种情况下,同位素变化会影响分子中存在的元素(44Ca和40Ca,以及37Cl和35Cl)。因此,提出了两种不同的方法。本文讨论了检测像素数和分子光谱数的选择,以及对时间数据采用回归方法对Ca同位素分析的影响。总的来说,在信号可以从两个单独的峰中获得的情况下,使用三个探测器像素和使用这种回归方法往往会产生通过HR CS GFMAS进行同位素分析的最佳结果(0.5-1.0% RSD)。另一方面,为了通过监测CaCl同时进行Ca和Cl同位素分析,提出了一种机器学习策略。当同位素丰度至少为10%(绝对百分比误差中值为1.21%)时,该模型的性能是有希望的,而当其中一种同位素显示较低丰度时,误差会增加。为了在现实环境中检测这种表现不佳的情况,建议监控预测不确定性,以设置阈值并标记可靠性较差的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书