Design of experiments and bioanalytical LC–MS/MS method for analysis of melatonin and tasimelteon in rat brain homogenate with whiteness assessment

IF 5.1 2区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
BMC Chemistry Pub Date : 2026-05-02 Epub Date: 2026-06-29 DOI:10.1186/s13065-026-01808-y
Serkan Levent, Abeer Elriş, Hazal Avcı, Saniye Özcan, Nafiz Öncü Can
{"title":"Design of experiments and bioanalytical LC–MS/MS method for analysis of melatonin and tasimelteon in rat brain homogenate with whiteness assessment","authors":"Serkan Levent,&nbsp;Abeer Elriş,&nbsp;Hazal Avcı,&nbsp;Saniye Özcan,&nbsp;Nafiz Öncü Can","doi":"10.1186/s13065-026-01808-y","DOIUrl":null,"url":null,"abstract":"<div><p>Sleep disorders include a range of common problems that affect the quality of sleep at night and, as a result, impact an individual’s daily functioning. Treatment protocols vary from over-the-counter products to regulated pharmaceuticals. Melatonin and Tasimelteon are two compounds utilized for severe to moderate sleeping disorders. This study developed and validated a sensitive, simple bioanalytical LC–MS/MS method for the measurement of Melatonin and Tasimelteon in spiked rat brain tissue. Chromatographic analyses were conducted in isocratic mode, with Citalopram selected as an appropriate internal standard. The Supelco Ascentis® Express Phenyl-Hexyl column was used for the stationary phase, and the mobile phase comprised 0.2% formic acid in a mixture of acetonitrile and water (65:35, <i>v/v</i>). A response surface methodology is applied. The Box-Behnken design was used to optimize the influence of three independent factors (acetonitrile%, formic acid%, and flow rate (mL/min)) on the response. The study focused on finding the most significant factors influencing chromatographic separation, namely the resolution between Tasimelteon and Melatonin, as well as the tailing factors of both. Statistical analysis of variance provided the optimal conditions for separating the substances as well as the most influential factors. Validation of the analytical method was conducted in accordance with the International Council for Harmonization guideline M10 related to bioanalytical method validation. The method validated was precise and linear in 55.00–1650 (ng/mL) and 20–600 (ng/mL) for the Melatonin and Tasimelteon, respectively. The validated method’s lower limit of quantification values was 55 and 20 ng/mL for Melatonin and Tasimelteon, respectively. For Melatonin, intraday accuracy (recovery, %) ranged from 96.53% to 102.68%, and precision (expressed as relative standard deviation) ranged from 0.26% to 0.96%. And inter-day accuracy ranged from 96.58% to 103.08%, and inter-day precision ranged from 0.33% to 3.55%. Intraday accuracy results for Tasimelteon 99.61%-103. 75% precision results were in the range 0.23%–0.93%; additionally, inter-day accuracy was 99.37–103.87%, and the precision range was 1.04–2.11%. The total run time was 3 min, with retention time for Melatonin and Tasimelteon at 1.9 and 2.5 min, respectively, achieving effective chromatographic separation under optimum conditions. The Red Green Blue 12 score for whiteness was determined to be 79.2%.</p></div>","PeriodicalId":496,"journal":{"name":"BMC Chemistry","volume":"20 1","pages":""},"PeriodicalIF":5.1000,"publicationDate":"2026-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1186/s13065-026-01808-y.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1186/s13065-026-01808-y","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Sleep disorders include a range of common problems that affect the quality of sleep at night and, as a result, impact an individual’s daily functioning. Treatment protocols vary from over-the-counter products to regulated pharmaceuticals. Melatonin and Tasimelteon are two compounds utilized for severe to moderate sleeping disorders. This study developed and validated a sensitive, simple bioanalytical LC–MS/MS method for the measurement of Melatonin and Tasimelteon in spiked rat brain tissue. Chromatographic analyses were conducted in isocratic mode, with Citalopram selected as an appropriate internal standard. The Supelco Ascentis® Express Phenyl-Hexyl column was used for the stationary phase, and the mobile phase comprised 0.2% formic acid in a mixture of acetonitrile and water (65:35, v/v). A response surface methodology is applied. The Box-Behnken design was used to optimize the influence of three independent factors (acetonitrile%, formic acid%, and flow rate (mL/min)) on the response. The study focused on finding the most significant factors influencing chromatographic separation, namely the resolution between Tasimelteon and Melatonin, as well as the tailing factors of both. Statistical analysis of variance provided the optimal conditions for separating the substances as well as the most influential factors. Validation of the analytical method was conducted in accordance with the International Council for Harmonization guideline M10 related to bioanalytical method validation. The method validated was precise and linear in 55.00–1650 (ng/mL) and 20–600 (ng/mL) for the Melatonin and Tasimelteon, respectively. The validated method’s lower limit of quantification values was 55 and 20 ng/mL for Melatonin and Tasimelteon, respectively. For Melatonin, intraday accuracy (recovery, %) ranged from 96.53% to 102.68%, and precision (expressed as relative standard deviation) ranged from 0.26% to 0.96%. And inter-day accuracy ranged from 96.58% to 103.08%, and inter-day precision ranged from 0.33% to 3.55%. Intraday accuracy results for Tasimelteon 99.61%-103. 75% precision results were in the range 0.23%–0.93%; additionally, inter-day accuracy was 99.37–103.87%, and the precision range was 1.04–2.11%. The total run time was 3 min, with retention time for Melatonin and Tasimelteon at 1.9 and 2.5 min, respectively, achieving effective chromatographic separation under optimum conditions. The Red Green Blue 12 score for whiteness was determined to be 79.2%.

Abstract Image

大鼠脑匀浆中褪黑素和塔西美素的实验设计及生物分析LC-MS/MS方法。
睡眠障碍包括一系列影响夜间睡眠质量的常见问题,从而影响个人的日常功能。治疗方案从非处方产品到管制药品各不相同。褪黑素和塔西美酮是两种用于重度至中度睡眠障碍的化合物。本研究建立并验证了一种灵敏、简单的生物分析LC-MS/MS方法,用于测定尖刺大鼠脑组织中褪黑素和塔西美酮的含量。色谱分析采用等温模式,选择西酞普兰作为合适的内标。固定相采用Supelco Ascentis®Express苯基己基色谱柱,流动相为0.2%甲酸,乙腈和水的混合物(65:35,v/v)。应用了响应面法。采用Box-Behnken设计优化三个独立因素(乙腈%、甲酸%、流速(mL/min))对反应的影响。本研究的重点是寻找影响色谱分离最显著的因素,即塔西美龙与褪黑素的分离度,以及二者的尾效应因素。方差统计分析提供了物质分离的最佳条件和影响因素。分析方法的验证是按照国际统一理事会关于生物分析方法验证的指南M10进行的。该方法在55.00 ~ 1650 (ng/mL)和20 ~ 600 (ng/mL)范围内具有良好的线性关系。经验证的方法对褪黑素和塔西美雄的定量下限分别为55和20 ng/mL。对于褪黑素,日内准确度(回收率,%)范围为96.53% ~ 102.68%,精密度(以相对标准偏差表示)范围为0.26% ~ 0.96%。日间精度范围为96.58% ~ 103.08%,日间精度范围为0.33% ~ 3.55%。Tasimelteon的日内准确度为99.61% ~ 103。75%精密度结果在0.23% ~ 0.93%范围内;日间准确度为99.37 ~ 103.87%,精密度范围为1.04 ~ 2.11%。总运行时间为3 min,其中褪黑素停留时间为1.9 min,塔西美龙停留时间为2.5 min,在最佳条件下实现了有效的色谱分离。白度的红绿蓝12评分确定为79.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Chemistry
BMC Chemistry Chemistry-General Chemistry
CiteScore
5.30
自引率
2.20%
发文量
92
审稿时长
27 weeks
期刊介绍: BMC Chemistry, formerly known as Chemistry Central Journal, is now part of the BMC series journals family. Chemistry Central Journal has served the chemistry community as a trusted open access resource for more than 10 years – and we are delighted to announce the next step on its journey. In January 2019 the journal has been renamed BMC Chemistry and now strengthens the BMC series footprint in the physical sciences by publishing quality articles and by pushing the boundaries of open chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书