Yuwei Zhu;Carla Riera-Llobet;Celeste Fleta;María Manna;Amélia Maia Leite;Gastón García López;Vicente García Távora;Diana Bachiller-Perea;Quentin Mouchard;Consuelo Guardiola
{"title":"Microdosimetry Maps in Continuous and Pulsed Alpha Beams","authors":"Yuwei Zhu;Carla Riera-Llobet;Celeste Fleta;María Manna;Amélia Maia Leite;Gastón García López;Vicente García Távora;Diana Bachiller-Perea;Quentin Mouchard;Consuelo Guardiola","doi":"10.1109/TRPMS.2025.3620266","DOIUrl":null,"url":null,"abstract":"The experimental assessment of the linear energy transfer (LET) at micrometric scale with high resolution is mandatory to achieve biologically optimized treatment plans in Hadron therapy. Therefore, it is crucial to create active radiation sensors able to quantify microdosimetry distributions in three-dimensions under clinical conditions. We have quantified the first microdosimetry 2-D-maps delivered by alpha beams with the highest resolution so far (<inline-formula> <tex-math>$400~\\mu $ </tex-math></inline-formula>m <inline-formula> <tex-math>$\\times 600~\\mu $ </tex-math></inline-formula>m) using a customized sensor. It consists of 3 multiarrays of <inline-formula> <tex-math>$50~3\\times 3$ </tex-math></inline-formula> microdetectors with a pitch of <inline-formula> <tex-math>$200~\\mu $ </tex-math></inline-formula>m that cover a total radiation-sensitive area of 9 cm <inline-formula> <tex-math>$\\times 0$ </tex-math></inline-formula>.4 mm. The microdetectors are based on a novel 3-D-cylindrical silicon architecture with 25-<inline-formula> <tex-math>$\\mu $ </tex-math></inline-formula>m diameter and 20-<inline-formula> <tex-math>$\\mu $ </tex-math></inline-formula>m thickness. The back-side of these sensors is etched to avoid back-scattering contributions in heavy ion fields. This system was calibrated with alpha beams from 5.75 to 20 MeV in the Accélérateur Linéaire et Tandem à Orsay (ALTO), France, and irradiated with pulsed beams (from <inline-formula> <tex-math>$1.4~\\mu $ </tex-math></inline-formula>s to <inline-formula> <tex-math>$3.3~\\mu $ </tex-math></inline-formula>s pulse widths) of 7.5 MeV alphas in the Centro de Micro-Análisis de Materiales (CMAM), Spain. We worked with clinical equivalent fluence rates in both continuous irradiation mode (<inline-formula> <tex-math>$\\sim ~10{^{{8}}}$ </tex-math></inline-formula> cm<inline-formula> <tex-math>${^{-}2 } \\cdot $ </tex-math></inline-formula>s<inline-formula> <tex-math>${}^{-}1 $ </tex-math></inline-formula>) and in pulsed regimes with higher fluence rates up to <inline-formula> <tex-math>$\\sim ~10{^{{10}~}}$ </tex-math></inline-formula>cm<inline-formula> <tex-math>$\\cdot {^{-}2 }$ </tex-math></inline-formula>s<inline-formula> <tex-math>${}^{-}1 $ </tex-math></inline-formula>. Measurements of pulse height spectra were collected with the sensor in both modes. The experimental results were crosschecked with Monte Carlo simulations using the GATE code. The simulated spectral shapes and peak positions showed good agreement with the experimental data, with relative differences of less than 3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"10 5","pages":"799-814"},"PeriodicalIF":3.8000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11203787/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The experimental assessment of the linear energy transfer (LET) at micrometric scale with high resolution is mandatory to achieve biologically optimized treatment plans in Hadron therapy. Therefore, it is crucial to create active radiation sensors able to quantify microdosimetry distributions in three-dimensions under clinical conditions. We have quantified the first microdosimetry 2-D-maps delivered by alpha beams with the highest resolution so far ($400~\mu $ m $\times 600~\mu $ m) using a customized sensor. It consists of 3 multiarrays of $50~3\times 3$ microdetectors with a pitch of $200~\mu $ m that cover a total radiation-sensitive area of 9 cm $\times 0$ .4 mm. The microdetectors are based on a novel 3-D-cylindrical silicon architecture with 25-$\mu $ m diameter and 20-$\mu $ m thickness. The back-side of these sensors is etched to avoid back-scattering contributions in heavy ion fields. This system was calibrated with alpha beams from 5.75 to 20 MeV in the Accélérateur Linéaire et Tandem à Orsay (ALTO), France, and irradiated with pulsed beams (from $1.4~\mu $ s to $3.3~\mu $ s pulse widths) of 7.5 MeV alphas in the Centro de Micro-Análisis de Materiales (CMAM), Spain. We worked with clinical equivalent fluence rates in both continuous irradiation mode ($\sim ~10{^{{8}}}$ cm${^{-}2 } \cdot $ s${}^{-}1 $ ) and in pulsed regimes with higher fluence rates up to $\sim ~10{^{{10}~}}$ cm$\cdot {^{-}2 }$ s${}^{-}1 $ . Measurements of pulse height spectra were collected with the sensor in both modes. The experimental results were crosschecked with Monte Carlo simulations using the GATE code. The simulated spectral shapes and peak positions showed good agreement with the experimental data, with relative differences of less than 3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes.
在微米尺度下高分辨率的线性能量传递(LET)实验评估是强子治疗中生物优化治疗方案的必要条件。因此,在临床条件下,创建能够量化三维微剂量分布的主动辐射传感器至关重要。我们已经使用定制的传感器量化了迄今为止最高分辨率($400~\mu $ m $\times 600~\mu $ m)的alpha光束提供的第一个微剂量二维图。它由3个多阵列$50~3\times 3$微探测器组成,其间距为$200~\mu $ m,覆盖了9厘米的总辐射敏感区域$\times 0$。4mm。微探测器是基于一个新的三维圆柱形硅结构,直径为25- $\mu $ m,厚度为20- $\mu $ m。这些传感器的背面被蚀刻以避免重离子场中的后向散射。该系统在法国的acc Orsay (ALTO)用5.75 - 20 MeV的α光束进行校准,在西班牙的Micro-Análisis材料中心(cam)用7.5 MeV的脉冲光束(脉冲宽度从$1.4~\mu $ s到$3.3~\mu $ s)进行照射。我们在连续照射模式($\sim ~10{^{{8}}}$ cm ${^{-}2 } \cdot $ s ${}^{-}1 $)和更高辐照率($\sim ~10{^{{10}~}}$ cm $\cdot {^{-}2 }$ s ${}^{-}1 $)的脉冲模式下使用临床等效辐照率。在两种模式下采集了脉冲高度光谱的测量值。实验结果与使用GATE代码的蒙特卡罗模拟交叉核对。模拟的光谱形状和峰位与实验数据吻合较好,相对差值小于3.5% for all the energies studied. Results show that the new microdosimetry array, specially manufactured for ions, is a reliable tool for LET characterization of ions in both continuous and pulsed modes.