{"title":"Adaptive Diffusion Models for Sparse-View Motion-Corrected Head Cone-beam CT","authors":"Antoine De Paepe;Alexandre Bousse;Clémentine Phung-Ngoc;Youness Mellak;Dimitris Visvikis","doi":"10.1109/TRPMS.2025.3637124","DOIUrl":null,"url":null,"abstract":"Cone-beam computed tomography (CBCT) is an imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion, especially under sparse-view settings used to reduce dose, which can result in severe image artifacts. In this work, we propose a novel framework combining joint reconstruction and motion estimation (JRM) with an adaptive diffusion model (ADM) that simultaneously addresses motion compensation and sparse-view reconstruction in head cone-beam computed tomography (CBCT). Leveraging recent advances in diffusion-based generative models, our method integrates a wavelet-domain diffusion prior into an iterative reconstruction pipeline to guide the solution toward anatomically plausible volumes while estimating rigid motion parameters in a blind fashion. We evaluate our method on simulated motion-affected CBCT data derived from real clinical computed tomography (CT) volumes. Experimental results demonstrate that JRM-ADM achieves consistent quantitative improvements over both traditional and learning-based baselines. In highly undersampled cases, JRM-ADM improves peak signal-to-noise ratio (PSNR) by more than 4 dB and structural similarity index measure (SSIM) by 0.10 compared to the baseline motion-corrected (MC) reconstruction method. These results highlight the potential of our approach to enable motion-robust, low-dose CBCT imaging, paving the way for improved clinical viability. The project page is available at <uri>https://antoinedepaepe.github.io/jrm-adm-io/</uri>.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"10 5","pages":"662-672"},"PeriodicalIF":3.8000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11269028/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Cone-beam computed tomography (CBCT) is an imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion, especially under sparse-view settings used to reduce dose, which can result in severe image artifacts. In this work, we propose a novel framework combining joint reconstruction and motion estimation (JRM) with an adaptive diffusion model (ADM) that simultaneously addresses motion compensation and sparse-view reconstruction in head cone-beam computed tomography (CBCT). Leveraging recent advances in diffusion-based generative models, our method integrates a wavelet-domain diffusion prior into an iterative reconstruction pipeline to guide the solution toward anatomically plausible volumes while estimating rigid motion parameters in a blind fashion. We evaluate our method on simulated motion-affected CBCT data derived from real clinical computed tomography (CT) volumes. Experimental results demonstrate that JRM-ADM achieves consistent quantitative improvements over both traditional and learning-based baselines. In highly undersampled cases, JRM-ADM improves peak signal-to-noise ratio (PSNR) by more than 4 dB and structural similarity index measure (SSIM) by 0.10 compared to the baseline motion-corrected (MC) reconstruction method. These results highlight the potential of our approach to enable motion-robust, low-dose CBCT imaging, paving the way for improved clinical viability. The project page is available at https://antoinedepaepe.github.io/jrm-adm-io/.
稀疏视图运动校正头锥束CT的自适应扩散模型
锥束计算机断层扫描(CBCT)因其可及性和较低的辐射剂量而被广泛应用于头颈部诊断。然而,其相对较长的采集时间使其容易受到患者运动的影响,特别是在用于减少剂量的稀疏视图设置下,这可能导致严重的图像伪影。在这项工作中,我们提出了一个结合关节重建和运动估计(JRM)与自适应扩散模型(ADM)的新框架,同时解决头部锥束计算机断层扫描(CBCT)中的运动补偿和稀疏视图重建问题。利用基于扩散的生成模型的最新进展,我们的方法将小波域扩散先验集成到迭代重建管道中,以盲估计刚性运动参数的同时将解决方案引导到解剖学上合理的体积。我们对来自真实临床计算机断层扫描(CT)体积的模拟运动影响的CBCT数据进行了评估。实验结果表明,JRM-ADM在传统和基于学习的基线上都实现了一致的定量改进。在高度欠采样的情况下,与基线运动校正(MC)重建方法相比,JRM-ADM将峰值信噪比(PSNR)提高了4 dB以上,结构相似性指数(SSIM)提高了0.10。这些结果突出了我们的方法在运动稳健、低剂量CBCT成像方面的潜力,为提高临床可行性铺平了道路。项目页面可在https://antoinedepaepe.github.io/jrm-adm-io/上找到。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书