Comparison of the Accuracy of CBCT and MDCT Imaging Modalities in Determining the Distance between the Incus and the Facial Nerve and the Round Window and the Oval Window: A Cadaveric Cross-sectional Study :.

IF 0.6 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Galen Medical Journal Pub Date : 2025-12-16 eCollection Date: 2025-01-01 DOI:10.31661/gmj.vi.3919
Sanaz Sharifishoshtari, Nader Saki, Zohreh Roozbahani, Yasamin Mehrab, Ali Hesari
{"title":"Comparison of the Accuracy of CBCT and MDCT Imaging Modalities in Determining the Distance between the Incus and the Facial Nerve and the Round Window and the Oval Window: A Cadaveric Cross-sectional Study :.","authors":"Sanaz Sharifishoshtari, Nader Saki, Zohreh Roozbahani, Yasamin Mehrab, Ali Hesari","doi":"10.31661/gmj.vi.3919","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hearing loss is the most common birth defect, and cochlear implants are an effective treatment for severe sensorineural loss. This study compared CBCT and MDCT accuracy in measuring key ear structures to aid cochlear implant planning.</p><p><strong>Materials and methods: </strong>In this cadaveric cross-sectional laboratory study, 12 temporal bones along with their covering soft tissue in the archive of the ENT department of Imam Khomeini Hospital in Ahvaz were studied. Imaging was performed using high-resolution CBCT, low-resolution CBCT, and MDCT modalities. Measurements were performed by an oral and maxillofacial radiologist and a general radiologist. The obtained data were analyzed descriptively and analytically in SPSS21 software.</p><p><strong>Results: </strong>The results revealed a high agreement between the data related to the distance of the incus from the facial nerve and the distance of the oval window from the round window in High-resolution CBCT, Low-resolution CBCT, and MDCT images. However, there was a significant difference in the measurement of MDCT and low-resolution CBCT compared to high-resolution CBCT. There was no significant difference in the measurement between MDCT and low-resolution CBCT.</p><p><strong>Conclusion: </strong>Based on our study and some previous studies on quantitative measurements of CBCT and MDCT imaging, low-resolution CBCT can be more reliably replaced by MDCT and achieve acceptable results compared to MDCT using a lower radiation dose. More studies are needed regarding the significant difference between high-resolution CBCT and MDCT, but the higher resolution of the borders in high-resolution CBCT images may be the reason for this result.</p>","PeriodicalId":44017,"journal":{"name":"Galen Medical Journal","volume":"14 S Pt 1","pages":"e3919"},"PeriodicalIF":0.6000,"publicationDate":"2025-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12894818/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Galen Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/gmj.vi.3919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Hearing loss is the most common birth defect, and cochlear implants are an effective treatment for severe sensorineural loss. This study compared CBCT and MDCT accuracy in measuring key ear structures to aid cochlear implant planning.

Materials and methods: In this cadaveric cross-sectional laboratory study, 12 temporal bones along with their covering soft tissue in the archive of the ENT department of Imam Khomeini Hospital in Ahvaz were studied. Imaging was performed using high-resolution CBCT, low-resolution CBCT, and MDCT modalities. Measurements were performed by an oral and maxillofacial radiologist and a general radiologist. The obtained data were analyzed descriptively and analytically in SPSS21 software.

Results: The results revealed a high agreement between the data related to the distance of the incus from the facial nerve and the distance of the oval window from the round window in High-resolution CBCT, Low-resolution CBCT, and MDCT images. However, there was a significant difference in the measurement of MDCT and low-resolution CBCT compared to high-resolution CBCT. There was no significant difference in the measurement between MDCT and low-resolution CBCT.

Conclusion: Based on our study and some previous studies on quantitative measurements of CBCT and MDCT imaging, low-resolution CBCT can be more reliably replaced by MDCT and achieve acceptable results compared to MDCT using a lower radiation dose. More studies are needed regarding the significant difference between high-resolution CBCT and MDCT, but the higher resolution of the borders in high-resolution CBCT images may be the reason for this result.

CBCT和MDCT成像方式在确定Incus与面神经之间的距离以及圆形窗和椭圆形窗的准确性的比较:一项尸体横断面研究。
背景:听力损失是最常见的出生缺陷,人工耳蜗是治疗严重感觉神经损失的有效方法。本研究比较了CBCT和MDCT测量关键耳结构的准确性,以帮助人工耳蜗植入计划。材料和方法:在这个尸体横断面实验室研究中,研究了阿瓦士伊玛目霍梅尼医院耳鼻喉科档案中的12块颞骨及其覆盖的软组织。采用高分辨率CBCT、低分辨率CBCT和MDCT方式进行成像。测量由一名口腔颌面放射科医生和一名普通放射科医生进行。所得数据在SPSS21软件中进行描述性分析。结果:高分辨率CBCT、低分辨率CBCT和MDCT图像中incus与面神经的距离和椭圆窗与圆窗的距离数据高度一致。然而,与高分辨率CBCT相比,MDCT和低分辨率CBCT的测量结果存在显著差异。MDCT与低分辨率CBCT的测量结果无显著差异。结论:根据我们的研究和以往一些CBCT和MDCT成像定量测量的研究,与MDCT相比,低分辨率CBCT可以更可靠地替代MDCT,并且使用更低的辐射剂量获得可接受的结果。关于高分辨率CBCT与MDCT之间的显著差异还需要更多的研究,但高分辨率CBCT图像的边界分辨率更高可能是导致这一结果的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Galen Medical Journal
Galen Medical Journal MEDICINE, RESEARCH & EXPERIMENTAL-
自引率
0.00%
发文量
13
期刊介绍: GMJ is open access, peer-reviewed journal in English and supported by Noncommunicable Diseases (NCD) Research Center of Fasa University of Medical Sciences that publishing by Salvia Medical Sciences Ltd. GMJ will consider all types of the following scientific papers for publication: - Editorial’s choice - Original Researches - Review articles - Case reports - Case series - Letter (to editors, to authors, etc) - Short communications - Medical Idea
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书