Effects of coronal implant neck flutes on early peri-implant osteogenesis and stability.

IF 4.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Ziqi Xie, Toru Ogawa, Kenta Shobara, Nobuhiro Yoda
{"title":"Effects of coronal implant neck flutes on early peri-implant osteogenesis and stability.","authors":"Ziqi Xie, Toru Ogawa, Kenta Shobara, Nobuhiro Yoda","doi":"10.1186/s40729-026-00674-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Limited research has investigated how implant neck flute design influences early peri-implant osteogenesis and implant stability in vivo. This study evaluated the effects of different neck flute designs on peri-implant bone healing and osseointegration in rat tibiae.</p><p><strong>Methods: </strong>Three types of custom-made implants (13 mm total length, 8 mm screw part, 2 mm diameter) were used: Type A (4 coronal flutes, 1.50 mm length, 0.2 mm notch radius, 0.20 mm depth), Type B (4 coronal flutes, 1.50 mm length, 0.5 mm notch radius, 0.20 mm depth), and Type C (no coronal flutes). The implants were bilaterally inserted into the tibiae of 21 male Wistar rats. After 4 weeks of healing, removal torque testing, micro-computed tomography, histological, and histomorphometric assessments were performed to evaluate osseointegration and the quality and quantity of the peri-implant bone. The assessments included the relative gray value (RGV; water = 0, implant = 100), bone-to-implant contact (BIC), and peri-implant bone volume/tissue volume (BV/TV).</p><p><strong>Results: </strong>Removal torque tests demonstrated significant differences among implant types, with Type A and Type B implants exhibiting higher values than Type C. The RGV revealed no significant differences among groups. Histomorphometric analysis revealed no significant differences among groups.</p><p><strong>Conclusion: </strong>The coronal flute design was associated with improved implant stability and osseointegration compared to non-fluted implants. This suggests that neck flute designs may enhance early peri-implant osseointegration and stability.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"12 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2026-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13090460/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-026-00674-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Limited research has investigated how implant neck flute design influences early peri-implant osteogenesis and implant stability in vivo. This study evaluated the effects of different neck flute designs on peri-implant bone healing and osseointegration in rat tibiae.

Methods: Three types of custom-made implants (13 mm total length, 8 mm screw part, 2 mm diameter) were used: Type A (4 coronal flutes, 1.50 mm length, 0.2 mm notch radius, 0.20 mm depth), Type B (4 coronal flutes, 1.50 mm length, 0.5 mm notch radius, 0.20 mm depth), and Type C (no coronal flutes). The implants were bilaterally inserted into the tibiae of 21 male Wistar rats. After 4 weeks of healing, removal torque testing, micro-computed tomography, histological, and histomorphometric assessments were performed to evaluate osseointegration and the quality and quantity of the peri-implant bone. The assessments included the relative gray value (RGV; water = 0, implant = 100), bone-to-implant contact (BIC), and peri-implant bone volume/tissue volume (BV/TV).

Results: Removal torque tests demonstrated significant differences among implant types, with Type A and Type B implants exhibiting higher values than Type C. The RGV revealed no significant differences among groups. Histomorphometric analysis revealed no significant differences among groups.

Conclusion: The coronal flute design was associated with improved implant stability and osseointegration compared to non-fluted implants. This suggests that neck flute designs may enhance early peri-implant osseointegration and stability.

冠状种植体颈槽对种植体周围早期成骨及稳定性的影响。
目的:有限的研究探讨了种植体颈部凹槽设计如何影响种植体周围早期成骨和种植体体内稳定性。本研究评估了不同颈槽设计对大鼠胫骨种植体周围骨愈合和骨融合的影响。方法:采用A型(冠状槽4个,长度1.50 mm,缺口半径0.2 mm,深度0.20 mm)、B型(冠状槽4个,长度1.50 mm,缺口半径0.5 mm,深度0.20 mm)和C型(无冠状槽)3种定制种植体(总长度13mm,螺钉部分8mm,直径2mm)。将植入物植入21只雄性Wistar大鼠的胫骨。愈合4周后,进行移除扭矩测试、显微计算机断层扫描、组织学和组织形态学评估,以评估骨整合和种植体周围骨的质量和数量。评估包括相对灰度值(RGV;水= 0,种植体= 100)、骨与种植体接触(BIC)和种植体周围骨体积/组织体积(BV/TV)。结果:不同种植体类型间的移除扭矩测试差异显著,A型和B型种植体的移除扭矩值高于c型种植体,RGV组间无显著差异。组织形态学分析显示各组间无显著差异。结论:冠状槽设计与非槽状种植体相比,可改善种植体稳定性和骨整合。这表明颈槽设计可以增强早期种植体周围骨整合和稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书