Functional Regression Methods for Estimating 24-Hour Ambulatory Blood Pressure and Heart Rate Parameters in Narcolepsy Type 1.

Q1 Computer Science
Digital Biomarkers Pub Date : 2026-03-03 eCollection Date: 2026-01-01 DOI:10.1159/000550314
Marta Karas, Francesco Onorati, Raul Torres, Lucie Barateau, Yves Dauvilliers, Brian Tracey, Dmitri Volfson
{"title":"Functional Regression Methods for Estimating 24-Hour Ambulatory Blood Pressure and Heart Rate Parameters in Narcolepsy Type 1.","authors":"Marta Karas, Francesco Onorati, Raul Torres, Lucie Barateau, Yves Dauvilliers, Brian Tracey, Dmitri Volfson","doi":"10.1159/000550314","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The nocturnal dip, a physiological drop in nocturnal blood pressure (BP), is driven by the autonomic nervous system. A reduction of <10% during nocturnal sleep versus daytime wakefulness is considered a \"non-dipping\" BP pattern and associated with increased cardiovascular disease risk in the general population. This study aimed to compare different methods for estimating BP and heart rate (HR) nocturnal dip from ambulatory BP monitoring (ABPM) data in individuals with narcolepsy type 1 (NT1).</p><p><strong>Methods: </strong>Baseline ABPM data were from participants with NT1 in the randomized TAK-994 phase 2 clinical trial (NCT04096560). Sleep period time (SPT) windows were estimated from raw accelerometer data overlapping with baseline and week 3 ABPM visits. Three approaches estimated BP and HR dip: (1) fixed-window, with daytime defined as 06:00 to 22:00, nighttime as 00:00 to 06:00, and dip defined as a drop from the daytime to nighttime window average; (2) 24-h pattern employing a two-component cosinor model to estimate a continuous 24-h pattern of BP and HR, and defining dip as a drop from pattern average to its lowest point; and (3) actigraphy-based, with dip defined as a drop from non-SPT to SPT average of BP and HR, utilizing algorithmically identified SPT aiming to best reflect participants' actual sleep periods.</p><p><strong>Results: </strong>The analytic sample consisted of 31 participants with NT1. Comparing actigraphy-based dip with fixed-window and 24-h pattern dips, the 24-h pattern dip had higher Pearson's correlation than the fixed-window dip across all three parameters (0.91 vs. 0.87, 0.88 vs. 0.68, and 0.88 vs. 0.56 for systolic BP [SBP], diastolic BP [DBP], and HR, respectively). We found substantial between- and within-participant variability in SPT timing and duration. A total of 61% of participants had a fixed-window SBP dip <10%, and 41% had a fixed-window DBP dip <10%. The 30th percentile of SBP/DBP dip varied substantially across calculation methods: 3.8%/8.6% (fixed-window), 6.8%/14.1% (24-h pattern), and 6.7%/12.1% (actigraphy-based).</p><p><strong>Conclusion: </strong>Estimated dip values from the 24-h pattern approach with a two-component cosinor model for BP and HR were strongly correlated with actigraphy-based dip values, which utilized an objective algorithm to identify participants' sleep. The 24-h pattern approach offers a robust alternative to the fixed-window method for assessing dipping, especially in populations with sleep timing variations and disturbances, like NT1, and does not require simultaneous actigraphy measurement. The classification of a \"non-dipper\" varies depending on both the dip type (SBP vs. DBP) and the dip estimation method.</p>","PeriodicalId":11242,"journal":{"name":"Digital Biomarkers","volume":"10 1","pages":"79-89"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13082773/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digital Biomarkers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000550314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The nocturnal dip, a physiological drop in nocturnal blood pressure (BP), is driven by the autonomic nervous system. A reduction of <10% during nocturnal sleep versus daytime wakefulness is considered a "non-dipping" BP pattern and associated with increased cardiovascular disease risk in the general population. This study aimed to compare different methods for estimating BP and heart rate (HR) nocturnal dip from ambulatory BP monitoring (ABPM) data in individuals with narcolepsy type 1 (NT1).

Methods: Baseline ABPM data were from participants with NT1 in the randomized TAK-994 phase 2 clinical trial (NCT04096560). Sleep period time (SPT) windows were estimated from raw accelerometer data overlapping with baseline and week 3 ABPM visits. Three approaches estimated BP and HR dip: (1) fixed-window, with daytime defined as 06:00 to 22:00, nighttime as 00:00 to 06:00, and dip defined as a drop from the daytime to nighttime window average; (2) 24-h pattern employing a two-component cosinor model to estimate a continuous 24-h pattern of BP and HR, and defining dip as a drop from pattern average to its lowest point; and (3) actigraphy-based, with dip defined as a drop from non-SPT to SPT average of BP and HR, utilizing algorithmically identified SPT aiming to best reflect participants' actual sleep periods.

Results: The analytic sample consisted of 31 participants with NT1. Comparing actigraphy-based dip with fixed-window and 24-h pattern dips, the 24-h pattern dip had higher Pearson's correlation than the fixed-window dip across all three parameters (0.91 vs. 0.87, 0.88 vs. 0.68, and 0.88 vs. 0.56 for systolic BP [SBP], diastolic BP [DBP], and HR, respectively). We found substantial between- and within-participant variability in SPT timing and duration. A total of 61% of participants had a fixed-window SBP dip <10%, and 41% had a fixed-window DBP dip <10%. The 30th percentile of SBP/DBP dip varied substantially across calculation methods: 3.8%/8.6% (fixed-window), 6.8%/14.1% (24-h pattern), and 6.7%/12.1% (actigraphy-based).

Conclusion: Estimated dip values from the 24-h pattern approach with a two-component cosinor model for BP and HR were strongly correlated with actigraphy-based dip values, which utilized an objective algorithm to identify participants' sleep. The 24-h pattern approach offers a robust alternative to the fixed-window method for assessing dipping, especially in populations with sleep timing variations and disturbances, like NT1, and does not require simultaneous actigraphy measurement. The classification of a "non-dipper" varies depending on both the dip type (SBP vs. DBP) and the dip estimation method.

1型发作性睡病患者24小时动态血压和心率参数的功能回归方法
导语:夜间血压下降是一种夜间血压(BP)的生理下降,由自主神经系统驱动。基线ABPM数据来自随机TAK-994 2期临床试验(NCT04096560)中NT1患者。根据原始加速度计数据与基线和第3周ABPM访问重叠估计睡眠周期时间(SPT)窗口。BP和HR的倾角有三种估算方法:(1)固定窗口,白天定义为06:00 ~ 22:00,夜间定义为00:00 ~ 06:00,倾角定义为从白天到夜间窗口平均值的下降;(2) 24小时模式,采用双分量余弦模型估计BP和HR的连续24小时模式,并将倾角定义为从模式平均值到其最低点的下降;(3)基于活动记录,将BP和HR平均值从非睡眠状态降至睡眠状态,利用算法识别的睡眠状态,以最好地反映参与者的实际睡眠时间。结果:分析样本包括31名NT1患者。将基于活动图的血压下降与固定窗口和24小时模式的血压下降进行比较,24小时模式的血压下降在所有三个参数上都比固定窗口的血压下降具有更高的Pearson相关性(收缩压[SBP]、舒张压[DBP]和HR分别为0.91比0.87、0.88比0.68和0.88比0.56)。我们发现SPT的时间和持续时间在参与者之间和参与者内部存在很大的差异。结论:基于BP和HR双成分余弦模型的24小时模式方法的估计倾角值与基于活动图的倾角值密切相关,该方法使用了一种客观算法来识别参与者的睡眠。24小时模式方法提供了一种可靠的替代固定窗口方法来评估倾斜,特别是在睡眠时间变化和干扰的人群中,如NT1,并且不需要同时进行活动测量。“非潜水者”的分类取决于潜水类型(收缩压vs舒张压)和潜水估计方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Digital Biomarkers
Digital Biomarkers Medicine-Medicine (miscellaneous)
CiteScore
10.60
自引率
0.00%
发文量
12
审稿时长
23 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书