Robust Transducer–Reflector Distance Control in Acoustic Levitation

IF 1.8
Jan Helge Dörsam;Sven Suppelt;Alexander A. Altmann;Jun Liu;Chuanchao Xu;Christoph Haugwitz;Tomislav Maric;Dieter Bothe;Mario Kupnik
{"title":"Robust Transducer–Reflector Distance Control in Acoustic Levitation","authors":"Jan Helge Dörsam;Sven Suppelt;Alexander A. Altmann;Jun Liu;Chuanchao Xu;Christoph Haugwitz;Tomislav Maric;Dieter Bothe;Mario Kupnik","doi":"10.1109/OJUFFC.2026.3679991","DOIUrl":null,"url":null,"abstract":"Acoustic levitation enables contactless manipulation for applications in containerless processing in chemistry and materials science. Single-transducer levitators, consisting of an ultrasonic transducer and a reflector, offer a minimal hardware configuration but require precise control of the transducer–reflector distance <inline-formula> <tex-math>$H$ </tex-math></inline-formula>. We propose a distance stabilization system based on a motorized linear stage and a precision balance that measures the acoustic radiation force (ARF) as a time-averaged, surface-integrated force magnitude on the reflector. Because ARF versus <inline-formula> <tex-math>$H$ </tex-math></inline-formula> exhibits extremely narrow resonance peaks, micrometer-scale deviations markedly reduce force and destabilize levitation. In practice, high-power transducers are actively kept at resonance using resonance frequency tracking (RFT). As the tracked frequency changes, the wavelength changes as well and the optimal distance <inline-formula> <tex-math>$H$ </tex-math></inline-formula> shifts. We introduce a two-stage control strategy in order to robustly stabilize <inline-formula> <tex-math>$H$ </tex-math></inline-formula>. First, a physics-informed, one-sided adaptive hill climb algorithm locates the cavity resonance. Second, a physics-informed extremum-seeking controller maintains the experimentally determined resonance distance despite drift and disturbances, using only the absolute ARF feedback. Long-term validation at node index <inline-formula> <tex-math>$n$ </tex-math></inline-formula>  <inline-formula> <tex-math>$\\text {=}$ </tex-math></inline-formula> 5 confirmed that ARF remained within the 95% tolerance bound for two hours, ensuring stable levitation. Performance was limited by the balance, mainly due to its internal averaging time. This occasionally caused convergence to local maxima or temporary loss of track during object insertion. The strategy presented enables robust, long-duration operation of acoustic levitators.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"6 ","pages":"107-111"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11471825","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11471825/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/2 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Acoustic levitation enables contactless manipulation for applications in containerless processing in chemistry and materials science. Single-transducer levitators, consisting of an ultrasonic transducer and a reflector, offer a minimal hardware configuration but require precise control of the transducer–reflector distance $H$ . We propose a distance stabilization system based on a motorized linear stage and a precision balance that measures the acoustic radiation force (ARF) as a time-averaged, surface-integrated force magnitude on the reflector. Because ARF versus $H$ exhibits extremely narrow resonance peaks, micrometer-scale deviations markedly reduce force and destabilize levitation. In practice, high-power transducers are actively kept at resonance using resonance frequency tracking (RFT). As the tracked frequency changes, the wavelength changes as well and the optimal distance $H$ shifts. We introduce a two-stage control strategy in order to robustly stabilize $H$ . First, a physics-informed, one-sided adaptive hill climb algorithm locates the cavity resonance. Second, a physics-informed extremum-seeking controller maintains the experimentally determined resonance distance despite drift and disturbances, using only the absolute ARF feedback. Long-term validation at node index $n$   $\text {=}$  5 confirmed that ARF remained within the 95% tolerance bound for two hours, ensuring stable levitation. Performance was limited by the balance, mainly due to its internal averaging time. This occasionally caused convergence to local maxima or temporary loss of track during object insertion. The strategy presented enables robust, long-duration operation of acoustic levitators.
声悬浮鲁棒传感器-反射器距离控制
声学悬浮使非接触式操作应用于化学和材料科学的无容器处理。单换能器悬浮器由一个超声波换能器和一个反射器组成,提供了最小的硬件配置,但需要精确控制换能器与反射器的距离。我们提出了一种基于电动线性舞台和精密天平的距离稳定系统,该系统将声辐射力(ARF)作为反射器上的时间平均,表面集成的力大小来测量。由于ARF与$H$表现出极窄的共振峰,微米级的偏差显着降低了力并使悬浮不稳定。在实际应用中,大功率换能器采用共振频率跟踪(RFT)主动保持共振状态。随着跟踪频率的变化,波长也随之变化,最佳距离$H$移位。为了鲁棒稳定$H$,我们引入了一种两阶段控制策略。首先,采用一种基于物理信息的单侧自适应爬坡算法定位空腔共振。其次,一个物理信息极值寻求控制器保持实验确定的共振距离,尽管漂移和干扰,仅使用绝对ARF反馈。在节点索引$n$ $\text{=}$ 5处进行长期验证,确认ARF在两小时内保持在95%公差范围内,确保稳定悬浮。性能受到平衡的限制,主要是由于其内部平均时间。这偶尔会导致收敛到局部最大值或在对象插入期间暂时丢失跟踪。所提出的策略使声学悬浮器能够稳健、长时间地运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书