{"title":"Improved defocus stability in laser-induced breakdown spectroscopy via microlens array beam homogenization","authors":"Zixuan Li, Xuechen Niu, Xinrui Pan, Wei Guo, Chen Niu and Lianbo Guo","doi":"10.1039/D5JA00441A","DOIUrl":null,"url":null,"abstract":"<p >The significant signal fluctuation in laser-induced breakdown spectroscopy (LIBS) severely limits its quantitative analysis accuracy. Although beam homogenization has proven effective in mitigating these fluctuations by producing uniform ablation conditions, conventional diffractive optical elements (DOEs) are constrained by their requirement for single-transverse-mode lasers and exhibit strong sensitivity to defocus, restricting their applicability in practical LIBS environments. To address these limitations, we propose a beam homogenization strategy using a microlens array (MLA). We demonstrate that the MLA efficiently transforms a multimode laser beam (<em>M</em><small><sup>2</sup></small> = 5) into a top-hat-like profile with a periodic array distribution, thereby redistributing energy more uniformly across the focal region. This transformation suppresses air breakdown caused by localized energy concentration at the focus. Plasma imaging confirms the suppression of air breakdown and reveals highly symmetric plasma evolution within both positive and negative defocus ranges. As a result, the depth of focus (DOF) is extended from 3–3.25 mm to 7 mm, leading to improved defocus tolerance and enhanced spectral stability. In inclined surface scanning experiments on micro-alloyed steel, this DOF extension reduced the spectral signal's relative standard deviation (RSD) from 35–50% to around 20%, while increasing the signal intensity by a factor of 1.2 to 2. Furthermore, in calibration experiments simulating surface undulations under varying defocus distances, the root mean square error (RMSE) for Cu I 324.75 nm was substantially reduced from 1.836% to 0.687%. These results confirm that MLA-based beam homogenization is a robust, mode-insensitive, and highly effective solution for significantly improving the reliability and quantitative accuracy of LIBS on uneven surfaces.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 4","pages":" 1411-1419"},"PeriodicalIF":3.3000,"publicationDate":"2026-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d5ja00441a","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The significant signal fluctuation in laser-induced breakdown spectroscopy (LIBS) severely limits its quantitative analysis accuracy. Although beam homogenization has proven effective in mitigating these fluctuations by producing uniform ablation conditions, conventional diffractive optical elements (DOEs) are constrained by their requirement for single-transverse-mode lasers and exhibit strong sensitivity to defocus, restricting their applicability in practical LIBS environments. To address these limitations, we propose a beam homogenization strategy using a microlens array (MLA). We demonstrate that the MLA efficiently transforms a multimode laser beam (M2 = 5) into a top-hat-like profile with a periodic array distribution, thereby redistributing energy more uniformly across the focal region. This transformation suppresses air breakdown caused by localized energy concentration at the focus. Plasma imaging confirms the suppression of air breakdown and reveals highly symmetric plasma evolution within both positive and negative defocus ranges. As a result, the depth of focus (DOF) is extended from 3–3.25 mm to 7 mm, leading to improved defocus tolerance and enhanced spectral stability. In inclined surface scanning experiments on micro-alloyed steel, this DOF extension reduced the spectral signal's relative standard deviation (RSD) from 35–50% to around 20%, while increasing the signal intensity by a factor of 1.2 to 2. Furthermore, in calibration experiments simulating surface undulations under varying defocus distances, the root mean square error (RMSE) for Cu I 324.75 nm was substantially reduced from 1.836% to 0.687%. These results confirm that MLA-based beam homogenization is a robust, mode-insensitive, and highly effective solution for significantly improving the reliability and quantitative accuracy of LIBS on uneven surfaces.

Abstract Image

通过微透镜阵列光束均匀化提高激光诱导击穿光谱的离焦稳定性
激光诱导击穿光谱(LIBS)中明显的信号波动严重限制了其定量分析的准确性。虽然光束均匀化已被证明可以通过产生均匀的烧蚀条件来有效地减轻这些波动,但传统的衍射光学元件(do)受到单横模激光器要求的限制,并且对散焦具有很强的敏感性,限制了它们在实际LIBS环境中的适用性。为了解决这些限制,我们提出了一种使用微透镜阵列(MLA)的光束均匀化策略。我们证明了MLA有效地将多模激光束(M2 = 5)转换成具有周期性阵列分布的顶帽状轮廓,从而在焦点区域更均匀地重新分配能量。这种转变抑制了由焦点处局部能量集中引起的空气击穿。等离子体成像证实了空气击穿的抑制,并在正、负离焦范围内显示了高度对称的等离子体演化。因此,焦深(DOF)从3-3.25 mm扩展到7 mm,从而提高了离焦容忍度和增强了光谱稳定性。在微合金钢倾斜表面扫描实验中,该自由度扩展将光谱信号的相对标准偏差(RSD)从35-50%降低到20%左右,同时将信号强度提高了1.2 - 2倍。此外,在模拟不同离焦距离下表面波动的标定实验中,Cu I 324.75 nm的均方根误差(RMSE)从1.836%大幅降低到0.687%。这些结果证实,基于mla的光束均匀化是一种鲁棒、模式不敏感、高效的解决方案,可显著提高LIBS在不均匀表面上的可靠性和定量精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书