Optimization of laser-induced breakdown spectroscopy for Be element detection with self-absorption effect correction

IF 3.3 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Xiang Yu, Xuebin Su, Boping Li, Dan Zhao, Rui Yang, Zongyu Hou and Zhe Wang
{"title":"Optimization of laser-induced breakdown spectroscopy for Be element detection with self-absorption effect correction","authors":"Xiang Yu, Xuebin Su, Boping Li, Dan Zhao, Rui Yang, Zongyu Hou and Zhe Wang","doi":"10.1039/D5JA00463B","DOIUrl":null,"url":null,"abstract":"<p >The laser-induced breakdown spectroscopy detection of the Be element can provide on-site rapid detection technology in the field of geological exploration. The self-absorption effect of Be results in weaker detection accuracy in the medium to high content range. This study calculated the self-absorption parameters for the self-absorption effect of the Be element, and optimized the detection delay and laser energy with the goal of reducing the self-absorption effect. The influence of laser energy on the self-absorption effect with two different light collection angles was discussed through plasma imaging and spatially resolved spectroscopy. The variation in self-absorption with increasing energy is interpreted as the result of competition between two factors: the increase in plasma temperature and the increase in optical path length due to plasma volume expansion. The opposite trends observed in axial and radial spectroscopy are attributable to the different expansions of the plasma height and width. With optimized parameters, the calibration model was corrected for self-absorption effects, resulting in a linear detection range of 6 to 10 000 ppm, which broadens the range of on-site detection of Be containing minerals by LIBS.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 4","pages":" 1364-1374"},"PeriodicalIF":3.3000,"publicationDate":"2026-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2026/ja/d5ja00463b?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d5ja00463b","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The laser-induced breakdown spectroscopy detection of the Be element can provide on-site rapid detection technology in the field of geological exploration. The self-absorption effect of Be results in weaker detection accuracy in the medium to high content range. This study calculated the self-absorption parameters for the self-absorption effect of the Be element, and optimized the detection delay and laser energy with the goal of reducing the self-absorption effect. The influence of laser energy on the self-absorption effect with two different light collection angles was discussed through plasma imaging and spatially resolved spectroscopy. The variation in self-absorption with increasing energy is interpreted as the result of competition between two factors: the increase in plasma temperature and the increase in optical path length due to plasma volume expansion. The opposite trends observed in axial and radial spectroscopy are attributable to the different expansions of the plasma height and width. With optimized parameters, the calibration model was corrected for self-absorption effects, resulting in a linear detection range of 6 to 10 000 ppm, which broadens the range of on-site detection of Be containing minerals by LIBS.

Abstract Image

自吸收效应校正的激光诱导击穿光谱对Be元素检测的优化
激光诱导击穿光谱法检测Be元素可为地质勘探领域提供现场快速检测技术。由于Be的自吸收效应,在中高含量范围内检测精度较低。本研究计算了Be元素自吸收效应的自吸收参数,并以减小自吸收效应为目标,优化了探测延迟和激光能量。利用等离子体成像和空间分辨光谱技术,讨论了激光能量对两种不同集光角度下的自吸收效应的影响。自吸收随能量增加的变化可以解释为两个因素竞争的结果:等离子体温度的增加和等离子体体积膨胀引起的光程长度的增加。在轴向和径向光谱中观察到的相反趋势归因于等离子体高度和宽度的不同扩展。通过优化后的参数,校正了校准模型的自吸收效应,得到了6 ~ 10000 ppm的线性检测范围,拓宽了LIBS对含Be矿物的现场检测范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书