A dual-standard matrix-matched calibration strategy for LA-ICP-MS elemental quantitative imaging of calcium oxalate–uric acid dual-matrix urinary stones

IF 3.3 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Xinyi Chen, Qingling Zhou, Duoduo Ao, Hui Hu, Hui Xu, Tengfei Zheng, Yongmei Hu, Ying Ye, Xiaoqing Yi, Jianzong Zhou and Yuqiu Ke
{"title":"A dual-standard matrix-matched calibration strategy for LA-ICP-MS elemental quantitative imaging of calcium oxalate–uric acid dual-matrix urinary stones","authors":"Xinyi Chen, Qingling Zhou, Duoduo Ao, Hui Hu, Hui Xu, Tengfei Zheng, Yongmei Hu, Ying Ye, Xiaoqing Yi, Jianzong Zhou and Yuqiu Ke","doi":"10.1039/D5JA00442J","DOIUrl":null,"url":null,"abstract":"<p >Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is a powerful technique for spatially resolved elemental imaging; however, its application in urinary stones, which often comprise mixed matrices such as calcium oxalate (CaOx) and uric acid (UA), presents significant challenges in matching the sample matrix with an appropriate matrix-matched external standard, especially when processing tens of thousands of LA-ICP-MS data points typically required for elemental imaging. This study presents a novel strategy that utilizes calcium (Ca) as a matrix tracer to distinguish between CaOx and UA components in complex urinary stones. Twelve consecutive quadrupole readouts of each scan were grouped, and a <em>t</em>-test was applied to identify matrix boundaries. This method enables the precise identification of boundaries on the scale of tens of micrometers that are indistinguishable to the naked eye in micrographs. Two matrices were thus identified, and a dual-standard calibration strategy was developed using in-house CaOx-1 and UA-6 reference pellets, enabling accurate and reproducible elemental quantification. This approach significantly reduces analytical errors arising from inappropriate selection of external or internal standards, previously estimated as −84% for Mg and up to 183% for Zn. The resulting elemental distribution images uncovered distinct compositional layering, which significantly improves the analytical performance of LA-ICP-MS in studying complex urinary stone compositions and holds promise for advancing research on their pathogenesis and treatment.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 4","pages":" 1199-1207"},"PeriodicalIF":3.3000,"publicationDate":"2026-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/ja/d5ja00442j","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is a powerful technique for spatially resolved elemental imaging; however, its application in urinary stones, which often comprise mixed matrices such as calcium oxalate (CaOx) and uric acid (UA), presents significant challenges in matching the sample matrix with an appropriate matrix-matched external standard, especially when processing tens of thousands of LA-ICP-MS data points typically required for elemental imaging. This study presents a novel strategy that utilizes calcium (Ca) as a matrix tracer to distinguish between CaOx and UA components in complex urinary stones. Twelve consecutive quadrupole readouts of each scan were grouped, and a t-test was applied to identify matrix boundaries. This method enables the precise identification of boundaries on the scale of tens of micrometers that are indistinguishable to the naked eye in micrographs. Two matrices were thus identified, and a dual-standard calibration strategy was developed using in-house CaOx-1 and UA-6 reference pellets, enabling accurate and reproducible elemental quantification. This approach significantly reduces analytical errors arising from inappropriate selection of external or internal standards, previously estimated as −84% for Mg and up to 183% for Zn. The resulting elemental distribution images uncovered distinct compositional layering, which significantly improves the analytical performance of LA-ICP-MS in studying complex urinary stone compositions and holds promise for advancing research on their pathogenesis and treatment.

Abstract Image

草酸钙-尿酸双基质尿路结石LA-ICP-MS元素定量成像的双标准基质匹配校准策略
激光烧蚀-电感耦合等离子体质谱(LA-ICP-MS)是一种强大的空间分辨元素成像技术;然而,它在尿路结石中的应用,通常包含混合基质,如草酸钙(CaOx)和尿酸(UA),在将样品基质与适当的基质匹配的外部标准中提出了重大挑战,特别是在处理元素成像通常需要的数万个LA-ICP-MS数据点时。本研究提出了一种利用钙(Ca)作为基质示踪剂来区分复杂尿路结石中CaOx和UA成分的新策略。将每次扫描的12个连续四极读数分组,并采用t检验来识别矩阵边界。这种方法可以精确地识别几十微米尺度上肉眼在显微照片上无法分辨的边界。因此,鉴定了两种基质,并使用内部CaOx-1和UA-6参考微球开发了双标准校准策略,实现了准确和可重复的元素定量。该方法显著减少了由于外部或内部标准选择不当而产生的分析误差,先前估计Mg为- 84%,Zn为183%。由此产生的元素分布图像揭示了不同的成分分层,这显著提高了LA-ICP-MS在研究复杂尿路结石成分方面的分析性能,并有望推进其发病机制和治疗的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书