Comparative Evaluation of VITEK® 2 AST-XN21, CHROMID® Colistin Agar, and Reference Broth Microdilution for Colistin Susceptibility Testing in Carbapenem-Resistant Acinetobacter baumannii and Klebsiella spp.

IF 1.2 4区 医学 Q4 MICROBIOLOGY
New Microbiologica Pub Date : 2026-04-01
Fatih Mehmet Akıllı, Çiğdem Yazar Yılmaz, Beste Akıllı, Mustafa Ulukanlıgil
{"title":"Comparative Evaluation of VITEK® 2 AST-XN21, CHROMID® Colistin Agar, and Reference Broth Microdilution for Colistin Susceptibility Testing in Carbapenem-Resistant Acinetobacter baumannii and Klebsiella spp.","authors":"Fatih Mehmet Akıllı, Çiğdem Yazar Yılmaz, Beste Akıllı, Mustafa Ulukanlıgil","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Rapid and accurate testing of colistin resistance is of paramount importance for the effective management of gram-negative infections in workflow laboratories. The objective of this study was to evaluate the performance of commercial VITEK®2 AST-XN21 cards and ChromID media via the reference Diagnostics MIC-COL method. Colistin susceptibility testing was conducted on 72 nonduplicate isolates using Diagnostics MIC-COL as the reference method, in comparison with the VITEK®2 AST-XN21 card and ChromID agar. The colistin resistance rate was 37.5% (27/72) according to the Diagnostics MIC-COL (Klebsiella spp. 34.4% (n=10), and Acinetobacter baumannii (A. baumannii) 39.5% (n=17)), whereas the VITEK®2 AST-XN21 card resistance rate was 41.3% (n=12) for Klebsiella spp. and 48.8% (n=21) for A. baumannii. The VITEK®2 AST-XN21 card was CA 91.6%, and the very major error (VME) and major error (ME) rates for all the isolates were 1.38% (n=1) and 6.9% (n=5), respectively. A. baumannii isolates were CA (37/43) 86%, VME (1/43) 2.3% and ME (5/43) 11.6% with XN21 cards. For Klebsiella spp., CA (29/29) was 100%, whereas ME and VME were not detected. The CA was 94.4% (68/72) for ChromID medium, 93% (40/43) for A. baumannii and 96.5% (28/29) for Klebsiella spp. These results indicated that the CHROMID medium is an appropriate method for the screening of colistin resistance. Nevertheless, it is imperative to exercise caution when interpreting the results of a commercial automated VITEK®2 AST-N21 card for colistin susceptibility testing.</p>","PeriodicalId":54723,"journal":{"name":"New Microbiologica","volume":"49 1","pages":"50-55"},"PeriodicalIF":1.2000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Microbiologica","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Rapid and accurate testing of colistin resistance is of paramount importance for the effective management of gram-negative infections in workflow laboratories. The objective of this study was to evaluate the performance of commercial VITEK®2 AST-XN21 cards and ChromID media via the reference Diagnostics MIC-COL method. Colistin susceptibility testing was conducted on 72 nonduplicate isolates using Diagnostics MIC-COL as the reference method, in comparison with the VITEK®2 AST-XN21 card and ChromID agar. The colistin resistance rate was 37.5% (27/72) according to the Diagnostics MIC-COL (Klebsiella spp. 34.4% (n=10), and Acinetobacter baumannii (A. baumannii) 39.5% (n=17)), whereas the VITEK®2 AST-XN21 card resistance rate was 41.3% (n=12) for Klebsiella spp. and 48.8% (n=21) for A. baumannii. The VITEK®2 AST-XN21 card was CA 91.6%, and the very major error (VME) and major error (ME) rates for all the isolates were 1.38% (n=1) and 6.9% (n=5), respectively. A. baumannii isolates were CA (37/43) 86%, VME (1/43) 2.3% and ME (5/43) 11.6% with XN21 cards. For Klebsiella spp., CA (29/29) was 100%, whereas ME and VME were not detected. The CA was 94.4% (68/72) for ChromID medium, 93% (40/43) for A. baumannii and 96.5% (28/29) for Klebsiella spp. These results indicated that the CHROMID medium is an appropriate method for the screening of colistin resistance. Nevertheless, it is imperative to exercise caution when interpreting the results of a commercial automated VITEK®2 AST-N21 card for colistin susceptibility testing.

VITEK®2 AST-XN21、CHROMID®粘菌素琼脂和参比肉汤微量稀释对耐碳青霉烯鲍曼不动杆菌和克雷伯氏菌粘菌素敏感性的比较评价
快速准确地检测粘菌素耐药性对于在工作流程实验室中有效管理革兰氏阴性感染至关重要。本研究的目的是通过参考Diagnostics MIC-COL方法评估商用VITEK®2 AST-XN21卡和ChromID介质的性能。采用Diagnostics MIC-COL作为参考方法,对72株非重复分离株进行粘菌素药敏试验,并与VITEK®2 AST-XN21卡和ChromID琼脂进行比较。根据Diagnostics MIC-COL(克雷伯氏菌属)和鲍曼不动杆菌(鲍曼不动杆菌属)的耐药率分别为34.4% (n=10)和39.5% (n=17),而VITEK®2 AST-XN21卡的耐药率分别为41.3% (n=12)和48.8% (n=21)。VITEK®2 AST-XN21卡的检出率为91.6%,所有分离株的甚大错误率(VME)和主要错误率(ME)分别为1.38% (n=1)和6.9% (n=5)。XN21卡分离的鲍曼不动杆菌CA (37/43) 86%, VME (1/43) 2.3%, ME(5/43) 11.6%。克雷伯氏菌的CA(29/29)为100%,ME和VME未检出。ChromID培养基的CA分别为94.4%(68/72)、93%(40/43)和96.5%(28/29),表明ChromID培养基是筛选粘菌素耐药的合适方法。然而,在解释商用自动VITEK®2 AST-N21卡用于粘菌素敏感性测试的结果时,必须谨慎行事。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
New Microbiologica
New Microbiologica 生物-微生物学
CiteScore
2.20
自引率
5.60%
发文量
40
审稿时长
6-12 weeks
期刊介绍: The publication, diffusion and furtherance of research and study on all aspects of basic and clinical Microbiology and related fields are the chief aims of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书