Periodontal health and orthodontic mini-screws: a cross-sectional study.

IF 3.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Periodontal and Implant Science Pub Date : 2026-08-01 Epub Date: 2026-03-23 DOI:10.5051/jpis.2503060153
Mehmet Selim Yildiz, Pelin Acar Ulutas, Aliye Akcalı
{"title":"Periodontal health and orthodontic mini-screws: a cross-sectional study.","authors":"Mehmet Selim Yildiz, Pelin Acar Ulutas, Aliye Akcalı","doi":"10.5051/jpis.2503060153","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Orthodontic mini-screws (OMSs) are widely used as temporary anchorage devices in orthodontics because they facilitate complex tooth movements without relying on patient compliance. Despite their advantages, concerns have been raised regarding potential adverse effects on periodontal health. This cross-sectional study aimed to assess the relationship between OMS and periodontal parameters in patients undergoing orthodontic treatment.</p><p><strong>Methods: </strong>A total of 132 patients with 160 OMS placements were included. Periodontal parameters, including plaque index (PI), gingival index (GI), probing depth (PD), recession depth, bleeding on probing (BOP), mucosal discomfort (MD), mucosal redness (MR), keratinized tissue width (KTW), supracrestal tissue height, and transmucosal soft tissue thickness, were evaluated at site-specific and full-mouth levels 3 months post-placement.</p><p><strong>Results: </strong>Significant differences were identified between site-level and full-mouth periodontal measurements, with site-level evaluations revealing higher PI, GI, PD, and BOP values (<i>P</i><0.05). Lower KTW and tension gauge (TG) values were correlated with higher MD and MR (<i>P</i><0.05). Moreover, lower TG values were associated with elevated periodontal inflammation markers, such as PI and PD, at both the site-specific and full-mouth levels (<i>P</i><0.05).</p><p><strong>Conclusions: </strong>These results highlight significant biomechanical and inflammatory interactions between OMS and periodontal tissues, emphasizing the need for meticulous mini-screw placement and careful periodontal monitoring. The findings also underscore the importance of individualized treatment plans that consider periodontal conditions to optimize OMS stability and minimize periodontal risks.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov Identifier: NCT07052747.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":"297-307"},"PeriodicalIF":3.1000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13547816/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2503060153","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Orthodontic mini-screws (OMSs) are widely used as temporary anchorage devices in orthodontics because they facilitate complex tooth movements without relying on patient compliance. Despite their advantages, concerns have been raised regarding potential adverse effects on periodontal health. This cross-sectional study aimed to assess the relationship between OMS and periodontal parameters in patients undergoing orthodontic treatment.

Methods: A total of 132 patients with 160 OMS placements were included. Periodontal parameters, including plaque index (PI), gingival index (GI), probing depth (PD), recession depth, bleeding on probing (BOP), mucosal discomfort (MD), mucosal redness (MR), keratinized tissue width (KTW), supracrestal tissue height, and transmucosal soft tissue thickness, were evaluated at site-specific and full-mouth levels 3 months post-placement.

Results: Significant differences were identified between site-level and full-mouth periodontal measurements, with site-level evaluations revealing higher PI, GI, PD, and BOP values (P<0.05). Lower KTW and tension gauge (TG) values were correlated with higher MD and MR (P<0.05). Moreover, lower TG values were associated with elevated periodontal inflammation markers, such as PI and PD, at both the site-specific and full-mouth levels (P<0.05).

Conclusions: These results highlight significant biomechanical and inflammatory interactions between OMS and periodontal tissues, emphasizing the need for meticulous mini-screw placement and careful periodontal monitoring. The findings also underscore the importance of individualized treatment plans that consider periodontal conditions to optimize OMS stability and minimize periodontal risks.

Trial registration: ClinicalTrials.gov Identifier: NCT07052747.

牙周健康与正畸微型螺钉:一项横断面研究。
目的:正畸微型螺钉(OMSs)在正畸治疗中被广泛用作临时固支装置,因为它们可以促进复杂的牙齿运动而不依赖于患者的依从性。尽管它们有优点,但对牙周健康的潜在不利影响也引起了关注。本横断面研究旨在评估正畸治疗患者OMS与牙周参数的关系。方法:共纳入132例患者,放置160个OMS。牙周参数,包括菌斑指数(PI)、牙龈指数(GI)、探诊深度(PD)、退退深度、探诊出血(BOP)、黏膜不适(MD)、黏膜发红(MR)、角化组织宽度(KTW)、切上组织高度和粘膜软组织厚度,在放置后3个月的部位和全口水平进行评估。结论:这些结果强调了OMS与牙周组织之间显著的生物力学和炎症相互作用,强调了精细微型螺钉放置和仔细牙周监测的必要性。研究结果还强调了考虑牙周状况的个性化治疗计划的重要性,以优化OMS的稳定性并将牙周风险降到最低。试验注册:ClinicalTrials.gov标识符:NCT07052747。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书