Clinical agreement between scale-aligned damping capacity and resonance frequency analyses for implant stability: a retrospective method-comparison study.

IF 3.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Periodontal and Implant Science Pub Date : 2026-08-01 Epub Date: 2026-03-25 DOI:10.5051/jpis.2505340267
Gwang-Young Jung, Inpyo Hong, Nicolas P A Müller, Franz J Strauss, Jung-Seok Lee
{"title":"Clinical agreement between scale-aligned damping capacity and resonance frequency analyses for implant stability: a retrospective method-comparison study.","authors":"Gwang-Young Jung, Inpyo Hong, Nicolas P A Müller, Franz J Strauss, Jung-Seok Lee","doi":"10.5051/jpis.2505340267","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the clinical agreement between resonance frequency analysis (RFA) and 2 scale-aligned damping capacity analysis (DCA) devices for assessing implant stability.</p><p><strong>Methods: </strong>In this retrospective method-comparison study (890 implants from 600 patients), implant stability was measured at up to 4 time points (T0-T3) using 1 RFA device and 2 DCA devices. Correlations between devices were assessed using Pearson's correlation coefficient. Agreement was evaluated using modified Bland-Altman analysis, and diagnostic accuracy was determined using receiver operating characteristic (ROC) curve analysis with an implant stability quotient threshold of 70. Changes in stability according to initial torque and simultaneous guided bone regeneration (GBR) or sinus grafting were analyzed using non-parametric statistical methods.</p><p><strong>Results: </strong>Significant moderate positive correlations were observed between RFA and each DCA device (<i>r</i>≈0.4; <i>P</i><0.001), and a strong correlation was observed between the 2 DCA devices (<i>r</i>=0.7; <i>P</i><0.001). Modified Bland-Altman analysis revealed systematic discrepancies, with DCA devices tending to overestimate stability in lower stability ranges relative to RFA. ROC analysis demonstrated fair diagnostic accuracy for both DCA devices (area under the curve≈0.70). Initial insertion torque and simultaneous GBR significantly influenced early implant stability; however, these differences diminished after 3 months.</p><p><strong>Conclusions: </strong>Scale-aligned DCA devices demonstrated acceptable clinical agreement and fair diagnostic accuracy relative to RFA. However, systematic discrepancies between DCA and RFA were observed, particularly in implants with lower stability. Clinicians should therefore interpret DCA measurements with caution in such cases.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":"338-350"},"PeriodicalIF":3.1000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13547820/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2505340267","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to evaluate the clinical agreement between resonance frequency analysis (RFA) and 2 scale-aligned damping capacity analysis (DCA) devices for assessing implant stability.

Methods: In this retrospective method-comparison study (890 implants from 600 patients), implant stability was measured at up to 4 time points (T0-T3) using 1 RFA device and 2 DCA devices. Correlations between devices were assessed using Pearson's correlation coefficient. Agreement was evaluated using modified Bland-Altman analysis, and diagnostic accuracy was determined using receiver operating characteristic (ROC) curve analysis with an implant stability quotient threshold of 70. Changes in stability according to initial torque and simultaneous guided bone regeneration (GBR) or sinus grafting were analyzed using non-parametric statistical methods.

Results: Significant moderate positive correlations were observed between RFA and each DCA device (r≈0.4; P<0.001), and a strong correlation was observed between the 2 DCA devices (r=0.7; P<0.001). Modified Bland-Altman analysis revealed systematic discrepancies, with DCA devices tending to overestimate stability in lower stability ranges relative to RFA. ROC analysis demonstrated fair diagnostic accuracy for both DCA devices (area under the curve≈0.70). Initial insertion torque and simultaneous GBR significantly influenced early implant stability; however, these differences diminished after 3 months.

Conclusions: Scale-aligned DCA devices demonstrated acceptable clinical agreement and fair diagnostic accuracy relative to RFA. However, systematic discrepancies between DCA and RFA were observed, particularly in implants with lower stability. Clinicians should therefore interpret DCA measurements with caution in such cases.

刻度对准阻尼能力和共振频率分析对种植体稳定性的临床一致性:一项回顾性方法比较研究。
目的:本研究旨在评估共振频率分析(RFA)和2种刻度对准阻尼容量分析(DCA)装置在评估种植体稳定性方面的临床一致性。方法:在这项回顾性方法比较研究中(来自600名患者的890个种植体),使用1个RFA装置和2个DCA装置在4个时间点(T0-T3)测量种植体稳定性。使用Pearson相关系数评估设备之间的相关性。采用改良Bland-Altman分析评估一致性,采用植入物稳定性商阈值为70的受试者工作特征(ROC)曲线分析确定诊断准确性。采用非参数统计方法分析初始扭矩和同时引导骨再生(GBR)或鼻窦移植的稳定性变化。结果:RFA与每个DCA装置之间存在显著的中度正相关(r≈0.4;Pr=0.7; p)。结论:相对于RFA,刻度校准DCA装置具有可接受的临床一致性和公平的诊断准确性。然而,观察到DCA和RFA之间的系统性差异,特别是在稳定性较低的种植体中。因此,在这种情况下,临床医生应谨慎解释DCA测量结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书