{"title":"Pediatric chest radiography in Fukushima prefecture: a multicentre organ dose assessment and optimization analysis.","authors":"Yoshiaki Hirofuji, Hazuki Manome, Koyo Sugai, Momoka Abe, Takaomi Harada","doi":"10.1088/1361-6498/ae5f27","DOIUrl":null,"url":null,"abstract":"<p><p>Pediatric patients are highly radiosensitive, and technical variation in chest radiography can substantially affect dose. Fukushima prefecture also faces persistent post-disaster radiation concerns and declining pediatric imaging experience due to demographic change. A 5 year-old anthropomorphic phantom with 50 radiophotoluminescent dosimeters was examined at 22 facilities. Organ absorbed doses and entrance surface air kerma (ESAK) were directly measured, and effective dose was calculated using International Commission on Radiological Protection Publication 103 tissue weighting factors. One statistical outlier identified by Tukey's extreme outlier criterion was excluded from outlier-excluded analyses. Across 22 facilities, ESAK ranged from 0.03 to 1.25 mGy (median 0.12 mGy) and effective dose from 3.4 to 180.1<i>μ</i>Sv (median 27.3<i>μ</i>Sv). After exclusion of one outlier, ESAK ranged from 0.03 to 0.26 mGy (median 0.12 mGy; 9-fold variation) and effective dose from 3.4 to 94.2<i>μ</i>Sv (median 27.2<i>μ</i>Sv; 28-fold variation). The 75th-percentile ESAK was 0.137 mGy, 2.5% below Japan diagnostic reference levels 2025 (0.14 mGy), although 5 of 21 facilities (23.8%) exceeded this level. Median effective dose was 1.4-fold higher than the international reference value (20<i>μ</i>Sv). Compared with posterior-anterior (PA) projection, anterior-posterior projection showed higher breast dose (151.8 ± 74.3 vs 18.6 ± 10.7<i>μ</i>Gy;<i>p</i>= 0.0011) and higher effective dose (55.9 ± 29.6 vs 21.7 ± 11.5<i>μ</i>Sv;<i>p</i>= 0.0059); the stomach dose difference was exploratory (<i>p</i>= 0.025), whereas the thyroid dose difference was not statistically significant (<i>p</i>= 0.050). Tube current-time product correlated positively with effective dose (<i>r</i>= 0.67,<i>p</i>< 0.001). Marked inter-facility variation indicates substantial opportunities for optimization through greater use of PA projection, appropriate source-to-image receptor distance extension, and careful mAs adjustment. In post-disaster regions with declining pediatric imaging experience, radiation protection may require integrated technical, educational, and societal support.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ae5f27","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Pediatric patients are highly radiosensitive, and technical variation in chest radiography can substantially affect dose. Fukushima prefecture also faces persistent post-disaster radiation concerns and declining pediatric imaging experience due to demographic change. A 5 year-old anthropomorphic phantom with 50 radiophotoluminescent dosimeters was examined at 22 facilities. Organ absorbed doses and entrance surface air kerma (ESAK) were directly measured, and effective dose was calculated using International Commission on Radiological Protection Publication 103 tissue weighting factors. One statistical outlier identified by Tukey's extreme outlier criterion was excluded from outlier-excluded analyses. Across 22 facilities, ESAK ranged from 0.03 to 1.25 mGy (median 0.12 mGy) and effective dose from 3.4 to 180.1μSv (median 27.3μSv). After exclusion of one outlier, ESAK ranged from 0.03 to 0.26 mGy (median 0.12 mGy; 9-fold variation) and effective dose from 3.4 to 94.2μSv (median 27.2μSv; 28-fold variation). The 75th-percentile ESAK was 0.137 mGy, 2.5% below Japan diagnostic reference levels 2025 (0.14 mGy), although 5 of 21 facilities (23.8%) exceeded this level. Median effective dose was 1.4-fold higher than the international reference value (20μSv). Compared with posterior-anterior (PA) projection, anterior-posterior projection showed higher breast dose (151.8 ± 74.3 vs 18.6 ± 10.7μGy;p= 0.0011) and higher effective dose (55.9 ± 29.6 vs 21.7 ± 11.5μSv;p= 0.0059); the stomach dose difference was exploratory (p= 0.025), whereas the thyroid dose difference was not statistically significant (p= 0.050). Tube current-time product correlated positively with effective dose (r= 0.67,p< 0.001). Marked inter-facility variation indicates substantial opportunities for optimization through greater use of PA projection, appropriate source-to-image receptor distance extension, and careful mAs adjustment. In post-disaster regions with declining pediatric imaging experience, radiation protection may require integrated technical, educational, and societal support.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.