Comparative performance of methadone urine immunoassays based on real-world data reveals assay interference.

IF 2.7 3区 医学 Q3 CHEMISTRY, ANALYTICAL
Jayson V Pagaduan
{"title":"Comparative performance of methadone urine immunoassays based on real-world data reveals assay interference.","authors":"Jayson V Pagaduan","doi":"10.1093/jat/bkag023","DOIUrl":null,"url":null,"abstract":"<p><p>Urine drug screen (UDS) immunoassays remain essential tools in clinical toxicology due to their rapid turnaround time and operational efficiency. However, their susceptibility to cross-reactivity continues to pose challenges, particularly in complex patient populations receiving multiple medications. Verification studies performed prior to assay implementation often rely on limited sample sets and may not fully capture real-world assay performance. Ongoing post-implementation monitoring, especially through comparison with confirmatory assays such as liquid chromatography-tandem mass spectrometry (LC-MS/MS), is therefore critical for identifying unexpected assay behavior and maintaining analytical reliability. This study evaluated the real-world concordance of two methadone immunoassays-the Architect MULTIGENT Methadone assay and the Roche Methadone II (MDN2) assay-with an in-house LC-MS/MS method capable of detecting methadone and its primary metabolite, 2-ethylidene-1, 5-dimethyl-3, 3-diphenylpyrrolidine (EDDP), at a cutoff concentration of 100 ng/mL. A total of 6753 Architect and 6255 Roche methadone screening results were retrospectively reviewed. The Architect assay demonstrated a 2.8% positivity rate, with 94.8% of positive screens confirmed by LC-MS/MS, corresponding to a 5.2% false-positive rate. In contrast, the Roche assay produced a higher positivity rate of 3.6% but a substantially lower confirmation rate of 69.8%, yielding a 30.2% false-positive rate (χ2 = 106, P < .05). Medication review of Roche false-positive cases revealed frequent use of quetiapine and vortioxetine, consistent with previously reported cross-reactivity. Additional medications historically associated with methadone immunoassay interference were also identified. These findings highlight significant performance differences between two widely used methadone immunoassays and underscore the importance of continuous, data-driven post-implementation surveillance. Confirmatory testing data such as LC-MS/MS results, can reveal clinically meaningful assay limitations, support accurate interpretation of unexpected results, and ultimately improve the reliability of UDS testing in diverse patient populations.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2026-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkag023","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Urine drug screen (UDS) immunoassays remain essential tools in clinical toxicology due to their rapid turnaround time and operational efficiency. However, their susceptibility to cross-reactivity continues to pose challenges, particularly in complex patient populations receiving multiple medications. Verification studies performed prior to assay implementation often rely on limited sample sets and may not fully capture real-world assay performance. Ongoing post-implementation monitoring, especially through comparison with confirmatory assays such as liquid chromatography-tandem mass spectrometry (LC-MS/MS), is therefore critical for identifying unexpected assay behavior and maintaining analytical reliability. This study evaluated the real-world concordance of two methadone immunoassays-the Architect MULTIGENT Methadone assay and the Roche Methadone II (MDN2) assay-with an in-house LC-MS/MS method capable of detecting methadone and its primary metabolite, 2-ethylidene-1, 5-dimethyl-3, 3-diphenylpyrrolidine (EDDP), at a cutoff concentration of 100 ng/mL. A total of 6753 Architect and 6255 Roche methadone screening results were retrospectively reviewed. The Architect assay demonstrated a 2.8% positivity rate, with 94.8% of positive screens confirmed by LC-MS/MS, corresponding to a 5.2% false-positive rate. In contrast, the Roche assay produced a higher positivity rate of 3.6% but a substantially lower confirmation rate of 69.8%, yielding a 30.2% false-positive rate (χ2 = 106, P < .05). Medication review of Roche false-positive cases revealed frequent use of quetiapine and vortioxetine, consistent with previously reported cross-reactivity. Additional medications historically associated with methadone immunoassay interference were also identified. These findings highlight significant performance differences between two widely used methadone immunoassays and underscore the importance of continuous, data-driven post-implementation surveillance. Confirmatory testing data such as LC-MS/MS results, can reveal clinically meaningful assay limitations, support accurate interpretation of unexpected results, and ultimately improve the reliability of UDS testing in diverse patient populations.

基于真实世界数据的美沙酮尿液免疫测定的比较性能揭示了测定干扰。
尿药物筛选(UDS)免疫测定由于其快速的周转时间和操作效率仍然是临床毒理学的重要工具。然而,它们对交叉反应的易感性继续构成挑战,特别是在接受多种药物治疗的复杂患者群体中。在分析实施之前进行的验证研究通常依赖于有限的样本集,可能无法完全捕获实际分析性能。因此,持续的实施后监测,特别是通过与液相色谱-串联质谱(LC-MS/MS)等验证性分析的比较,对于识别意外的分析行为和保持分析可靠性至关重要。本研究评估了两种美沙酮免疫测定法——Architect MULTIGENT美沙酮测定法和罗氏美沙酮II (MDN2)测定法的真实一致性,采用内部LC-MS/MS方法,能够检测美沙酮及其主要代谢物2-乙基- 1,5 -二甲基- 3,3 -二苯基吡啶(EDDP),截止浓度为100 ng/mL。回顾性分析了6753例Architect和6255例Roche美沙酮筛查结果。Architect试验的阳性率为2.8%,LC-MS/MS确认的阳性筛选率为94.8%,假阳性率为5.2%。相比之下,罗氏法的阳性率较高,为3.6%,但确证率明显较低,为69.8%,假阳性率为30.2% (χ2 = 106, P
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
20.00%
发文量
92
审稿时长
6-12 weeks
期刊介绍: The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation. Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书