Performance of CT-guided spatial normalization for semi-quantification of dopamine transporter SPECT and detection of nigrostriatal degeneration

IF 2.4 4区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Alae Eddine El Barkaoui, Christian Scheiber, Stephane Thobois, Ralph Buchert, Marc Janier, Thomas Grenier, Anthime Flaus
{"title":"Performance of CT-guided spatial normalization for semi-quantification of dopamine transporter SPECT and detection of nigrostriatal degeneration","authors":"Alae Eddine El Barkaoui,&nbsp;Christian Scheiber,&nbsp;Stephane Thobois,&nbsp;Ralph Buchert,&nbsp;Marc Janier,&nbsp;Thomas Grenier,&nbsp;Anthime Flaus","doi":"10.1007/s12149-026-02204-1","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The present study aims to assess the performance of a CT-guided spatial normalization method (CT-method) for the anatomical region-of-interest (ROI)-based semi-quantification of dopamine transporter (DAT) single photon emission computed tomography (SPECT) images and the detection of nigrostriatal degeneration as compared to an effective SPECT template-based method (MSPECT-method) and visual analysis performed by an expert reader.</p><h3>Methods</h3><p>Patients who underwent [<sup>123</sup>I]FP-CIT SPECT/CT in the <i>Hospices Civils de Lyon</i> between 2008 and 2018 for clinically uncertain parkinsonian syndromes were included. The proposed CT-method aimed to spatially normalize the jointly acquired CT scans and apply the deformation fields to the coregistered SPECT images. It was compared to an effective SPECT template-based method using multiple templates as target for the spatial normalization (MSPECT-method). The distribution of specific binding ratios (SBR) was compared between both methods and the SBR classifications were compared to an expert’s visual classification of the scans, which served as the reference.</p><h3>Results</h3><p>Overall, 1156 patients (mean age ± SD = 68.7 ± 11.5; 52.6% male) were included. The CT-method provided a good separation between the normal and reduced SBR, with a higher effect size of the distance between the Gaussians (3.31 vs 3.11) and smaller overlap (6.44% vs 8.96%) compared to the MSPECT-method. Both the CT-method and MSPECT-method demonstrated high classification accuracy (96.7%, 95% CI: 95.7-97.7% vs. 94.6%, 95% CI: 93.3-95.9%), sensitivity (96.0%, CI: 94.3-97.7% vs. 89.7%, CI: 87.1-92.3%), and specificity (97.3%, CI: 96.1-98.6% vs. 98.7%, CI: 97.9-99.6%), respectively.</p><h3>Conclusions</h3><p>The proposed CT-guided spatial normalization method for automated semi-quantitative [<sup>123</sup>I]FP-CIT SPECT analysis is a viable option when CT images are available. It offers objective spatial normalization and provides high accuracy for the detection of nigrostriatal degeneration, closely aligning with an expert’s visual interpretation.</p></div>","PeriodicalId":8007,"journal":{"name":"Annals of Nuclear Medicine","volume":"40 8","pages":"926 - 936"},"PeriodicalIF":2.4000,"publicationDate":"2026-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s12149-026-02204-1.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Nuclear Medicine","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s12149-026-02204-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The present study aims to assess the performance of a CT-guided spatial normalization method (CT-method) for the anatomical region-of-interest (ROI)-based semi-quantification of dopamine transporter (DAT) single photon emission computed tomography (SPECT) images and the detection of nigrostriatal degeneration as compared to an effective SPECT template-based method (MSPECT-method) and visual analysis performed by an expert reader.

Methods

Patients who underwent [123I]FP-CIT SPECT/CT in the Hospices Civils de Lyon between 2008 and 2018 for clinically uncertain parkinsonian syndromes were included. The proposed CT-method aimed to spatially normalize the jointly acquired CT scans and apply the deformation fields to the coregistered SPECT images. It was compared to an effective SPECT template-based method using multiple templates as target for the spatial normalization (MSPECT-method). The distribution of specific binding ratios (SBR) was compared between both methods and the SBR classifications were compared to an expert’s visual classification of the scans, which served as the reference.

Results

Overall, 1156 patients (mean age ± SD = 68.7 ± 11.5; 52.6% male) were included. The CT-method provided a good separation between the normal and reduced SBR, with a higher effect size of the distance between the Gaussians (3.31 vs 3.11) and smaller overlap (6.44% vs 8.96%) compared to the MSPECT-method. Both the CT-method and MSPECT-method demonstrated high classification accuracy (96.7%, 95% CI: 95.7-97.7% vs. 94.6%, 95% CI: 93.3-95.9%), sensitivity (96.0%, CI: 94.3-97.7% vs. 89.7%, CI: 87.1-92.3%), and specificity (97.3%, CI: 96.1-98.6% vs. 98.7%, CI: 97.9-99.6%), respectively.

Conclusions

The proposed CT-guided spatial normalization method for automated semi-quantitative [123I]FP-CIT SPECT analysis is a viable option when CT images are available. It offers objective spatial normalization and provides high accuracy for the detection of nigrostriatal degeneration, closely aligning with an expert’s visual interpretation.

ct引导下空间归一化对多巴胺转运体SPECT半定量和黑质纹状体变性检测的作用。
目的:本研究旨在评估ct引导的空间归一化方法(ct方法)在基于解剖感兴趣区(ROI)的多巴胺转运体(DAT)单光子发射计算机断层扫描(SPECT)图像的半定量和黑质纹状体变性检测方面的性能,并与基于SPECT模板的有效方法(mspect方法)和由专家读者进行的视觉分析进行比较。方法:纳入2008年至2018年期间在里昂平民医院接受[123I]FP-CIT SPECT/CT治疗临床不确定帕金森综合征的患者。提出的CT方法旨在对联合获取的CT扫描图像进行空间归一化,并将变形场应用于共配的SPECT图像。将其与一种有效的基于多模板的SPECT空间归一化方法(mspect方法)进行比较。比较两种方法的特异结合比(specific binding ratio, SBR)分布,并将SBR分类与专家对扫描图像的视觉分类进行比较,作为参考。结果:共纳入1156例患者(平均年龄±SD = 68.7±11.5,男性占52.6%)。与mspect方法相比,ct方法可以很好地分离正常和缩小的SBR,高斯距离的效应大小更高(3.31 vs 3.11),重叠更小(6.44% vs 8.96%)。ct法和mspect法均表现出较高的分类准确率(96.7%,95% CI: 95.7-97.7% vs. 94.6%, 95% CI: 93.3-95.9%)、灵敏度(96.0%,CI: 94.3-97.7% vs. 89.7%, CI: 87.1-92.3%)和特异性(97.3%,CI: 96.1-98.6% vs. 98.7%, CI: 97.9-99.6%)。结论:本文提出的CT引导空间归一化方法用于自动半定量[123I]FP-CIT SPECT分析是一种可行的选择,当CT图像可用时。它提供了客观的空间归一化,为黑质纹状体变性的检测提供了高精度,与专家的视觉解释密切一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Nuclear Medicine
Annals of Nuclear Medicine 医学-核医学
CiteScore
4.90
自引率
7.70%
发文量
111
审稿时长
4-8 weeks
期刊介绍: Annals of Nuclear Medicine is an official journal of the Japanese Society of Nuclear Medicine. It develops the appropriate application of radioactive substances and stable nuclides in the field of medicine. The journal promotes the exchange of ideas and information and research in nuclear medicine and includes the medical application of radionuclides and related subjects. It presents original articles, short communications, reviews and letters to the editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书