Breathable, biocompatible, long-term stability Ti3C2Tx bioelectrodes for real-time monitoring of electrophysiological signals

IF 6.4 2区 材料科学 Q1 CHEMISTRY, PHYSICAL
Jingxiao Liu, Zhaoyang Su, JingYue Xuan, Liubing Fan, Fangfang Gao, Xuan Zhao, Qingliang Liao and Yue Zhang
{"title":"Breathable, biocompatible, long-term stability Ti3C2Tx bioelectrodes for real-time monitoring of electrophysiological signals","authors":"Jingxiao Liu, Zhaoyang Su, JingYue Xuan, Liubing Fan, Fangfang Gao, Xuan Zhao, Qingliang Liao and Yue Zhang","doi":"10.1039/D6NH00022C","DOIUrl":null,"url":null,"abstract":"<p >Electrophysiological signals, generated from the directional transport of ions across cellular membranes, encode vital physiological information relevant to human health status. Electrophysiological signal monitoring serves as a critical approach for deciphering fundamental physiological processes and enabling precise disease diagnostics. Bioelectrodes are indispensable components for the acquisition of high-fidelity electrophysiological signals. However, sweat inevitably accumulates at the skin–electrode interface during continuous monitoring, which may irritate the skin or cause the electrodes to detach from the skin, affecting the acquisition of high-quality electrophysiological signals. A key challenge in ensuring the long-term utility of bioelectrodes lies in enhancing their breathability without impeding electrophysiological signal transmission. Therefore, we realized Ti<small><sub>3</sub></small>C<small><sub>2</sub></small>T<small><sub><em>x</em></sub></small> edge passivation by NaAsc and the preservation time at room temperature was increased to 30 days. On this basis, an antioxidant Ti<small><sub>3</sub></small>C<small><sub>2</sub></small>T<small><sub><em>x</em></sub></small> bioelectrode with high air permeability and biocompatibility was proposed. The bioelectrode has an excellent gas permeability of 1408.89 g m<small><sup>−2</sup></small> d<small><sup>−1</sup></small> and a low skin–electrode interface impedance of 1.83 × 10<small><sup>5</sup></small> Ω at 10 Hz. Moreover, the signal-to-noise ratio of the electromyography signal is 19.4 dB and the T/R wave intensity ratio of the electrocardiography signal is 0.4079, which is superior to that of the Ag/AgCl gel electrode. The bioelectrode with these optimized attributes enables stable, long-term monitoring of multiple electrophysiological modalities and excellent skin biocompatibility, providing a new approach for constructing a health monitoring and smart medical system.</p>","PeriodicalId":93,"journal":{"name":"Nanoscale Horizons","volume":" 6","pages":" 1710-1725"},"PeriodicalIF":6.4000,"publicationDate":"2026-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanoscale Horizons","FirstCategoryId":"88","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2026/nh/d6nh00022c","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Electrophysiological signals, generated from the directional transport of ions across cellular membranes, encode vital physiological information relevant to human health status. Electrophysiological signal monitoring serves as a critical approach for deciphering fundamental physiological processes and enabling precise disease diagnostics. Bioelectrodes are indispensable components for the acquisition of high-fidelity electrophysiological signals. However, sweat inevitably accumulates at the skin–electrode interface during continuous monitoring, which may irritate the skin or cause the electrodes to detach from the skin, affecting the acquisition of high-quality electrophysiological signals. A key challenge in ensuring the long-term utility of bioelectrodes lies in enhancing their breathability without impeding electrophysiological signal transmission. Therefore, we realized Ti3C2Tx edge passivation by NaAsc and the preservation time at room temperature was increased to 30 days. On this basis, an antioxidant Ti3C2Tx bioelectrode with high air permeability and biocompatibility was proposed. The bioelectrode has an excellent gas permeability of 1408.89 g m−2 d−1 and a low skin–electrode interface impedance of 1.83 × 105 Ω at 10 Hz. Moreover, the signal-to-noise ratio of the electromyography signal is 19.4 dB and the T/R wave intensity ratio of the electrocardiography signal is 0.4079, which is superior to that of the Ag/AgCl gel electrode. The bioelectrode with these optimized attributes enables stable, long-term monitoring of multiple electrophysiological modalities and excellent skin biocompatibility, providing a new approach for constructing a health monitoring and smart medical system.

Abstract Image

透气、生物相容性好、长期稳定的Ti3C2Tx生物电极,用于实时监测电生理信号。
电生理信号是离子在细胞膜上的定向传输产生的,它编码了与人体健康状况相关的重要生理信息。电生理信号监测是破译基本生理过程和实现精确疾病诊断的关键方法。生物电极是获取高保真电生理信号不可缺少的组成部分。然而,在连续监测过程中,汗液不可避免地在皮肤-电极界面积聚,可能会刺激皮肤或导致电极与皮肤分离,影响高质量电生理信号的获取。确保生物电极长期使用的关键挑战在于在不阻碍电生理信号传输的情况下增强其透气性。因此,我们通过NaAsc实现了Ti3C2Tx边缘钝化,并将室温保存时间延长至30天。在此基础上,提出了一种具有高透气性和生物相容性的抗氧化Ti3C2Tx生物电极。该生物电极具有优异的透气性1408.89 g m-2 d-1,在10 Hz时皮肤电极界面阻抗低,为1.83 × 105 Ω。肌电信号的信噪比为19.4 dB,心电图信号的T/R波强度比为0.4079,优于Ag/AgCl凝胶电极。具有这些优化属性的生物电极能够稳定、长期地监测多种电生理模式,并具有良好的皮肤生物相容性,为构建健康监测和智能医疗系统提供了新的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nanoscale Horizons
Nanoscale Horizons Materials Science-General Materials Science
CiteScore
16.30
自引率
1.00%
发文量
141
期刊介绍: Nanoscale Horizons stands out as a premier journal for publishing exceptionally high-quality and innovative nanoscience and nanotechnology. The emphasis lies on original research that introduces a new concept or a novel perspective (a conceptual advance), prioritizing this over reporting technological improvements. Nevertheless, outstanding articles showcasing truly groundbreaking developments, including record-breaking performance, may also find a place in the journal. Published work must be of substantial general interest to our broad and diverse readership across the nanoscience and nanotechnology community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书