Gait Event Detection From Thigh Segment Kinematics in Children With Crouch Gait

IF 3.9 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Jordan Dembsky;Noah Rubin;Thomas C. Bulea
{"title":"Gait Event Detection From Thigh Segment Kinematics in Children With Crouch Gait","authors":"Jordan Dembsky;Noah Rubin;Thomas C. Bulea","doi":"10.1109/JTEHM.2026.3679585","DOIUrl":null,"url":null,"abstract":"Objective: Wearable exoskeletons can improve walking in children with movement disorders by delivering precisely timed and scaled torques based on discrete gait phase. Most single-joint systems segment the gait cycle using underfoot force-sensitive resistors (FSRs), but FSRs are suboptimal for exoskeleton use in pathological gait due to fragile hardware and inconsistent foot loading/unloading. Thigh kinematics may provide more robust gait event detection (GED), yet this approach has not been evaluated in children with crouch gait, a key target population for pediatric exoskeleton therapy. This study aimed to: 1) assess feasibility of GED using thigh kinematics from ground-truth motion capture, 2) evaluate GED using a thigh-mounted inertial measurement unit (IMU), and 3) validate this method with a wearable knee exoskeleton in children with crouch gait.Methods and procedures: A novel thigh segment kinematics algorithm (TSKA) was developed to detect initial contact (IC) and terminal contact (TC) during overground walking. Algorithm performance was assessed using IMU-derived gait events compared to motion capture ground truth, then evaluated with a wearable knee exoskeleton.Results: Mean IMU-based timing errors for IC and TC were 38 and 84 ms, respectively. IC predictions occurred earlier than ground truth, whereas TC predictions varied. During exoskeleton walking, IMU-based GED significantly improved timing accuracy compared to FSR-based detection.Conclusion: The thigh-based kinematic algorithm, tuned for each individual with six or fewer strides, accurately detected gait events in children with crouch gait and outperformed FSR-based GED in an exoskeleton. These findings support further development for real-time exoskeleton control and gait assessment in individuals with pathological gait.","PeriodicalId":54255,"journal":{"name":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","volume":"14 ","pages":"188-197"},"PeriodicalIF":3.9000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11458653","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11458653/","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Wearable exoskeletons can improve walking in children with movement disorders by delivering precisely timed and scaled torques based on discrete gait phase. Most single-joint systems segment the gait cycle using underfoot force-sensitive resistors (FSRs), but FSRs are suboptimal for exoskeleton use in pathological gait due to fragile hardware and inconsistent foot loading/unloading. Thigh kinematics may provide more robust gait event detection (GED), yet this approach has not been evaluated in children with crouch gait, a key target population for pediatric exoskeleton therapy. This study aimed to: 1) assess feasibility of GED using thigh kinematics from ground-truth motion capture, 2) evaluate GED using a thigh-mounted inertial measurement unit (IMU), and 3) validate this method with a wearable knee exoskeleton in children with crouch gait.Methods and procedures: A novel thigh segment kinematics algorithm (TSKA) was developed to detect initial contact (IC) and terminal contact (TC) during overground walking. Algorithm performance was assessed using IMU-derived gait events compared to motion capture ground truth, then evaluated with a wearable knee exoskeleton.Results: Mean IMU-based timing errors for IC and TC were 38 and 84 ms, respectively. IC predictions occurred earlier than ground truth, whereas TC predictions varied. During exoskeleton walking, IMU-based GED significantly improved timing accuracy compared to FSR-based detection.Conclusion: The thigh-based kinematic algorithm, tuned for each individual with six or fewer strides, accurately detected gait events in children with crouch gait and outperformed FSR-based GED in an exoskeleton. These findings support further development for real-time exoskeleton control and gait assessment in individuals with pathological gait.
基于大腿段运动学的儿童蹲伏步态事件检测
目的:可穿戴外骨骼通过提供基于离散步态阶段的精确定时和缩放扭矩来改善运动障碍儿童的行走。大多数单关节系统使用脚底力敏感电阻(FSRs)来分割步态周期,但由于硬件脆弱和足部加载/卸载不一致,FSRs对于外骨骼在病理步态中的应用并不理想。大腿运动学可以提供更稳健的步态事件检测(GED),但这种方法尚未在蹲下步态的儿童中进行评估,而蹲下步态是儿科外骨骼治疗的关键目标人群。本研究旨在:1)利用地面真实运动捕获的大腿运动学来评估GED的可行性,2)利用大腿安装的惯性测量单元(IMU)来评估GED,以及3)用可穿戴膝关节外骨骼在蹲下步态儿童身上验证该方法。方法和步骤:开发了一种新的大腿段运动学算法(TSKA)来检测地上行走时的初始接触(IC)和终端接触(TC)。通过imu衍生的步态事件与动作捕捉地面真实情况进行比较,评估算法性能,然后使用可穿戴膝关节外骨骼进行评估。结果:IC和TC基于imu的平均时序误差分别为38和84 ms。IC的预测早于实际情况,而TC的预测则各不相同。在外骨骼行走过程中,与基于fsr的检测相比,基于imu的GED显着提高了定时精度。结论:基于腿的运动学算法,针对每个人6步或更少的步幅进行了调整,准确地检测了蹲伏步态儿童的步态事件,并且在外骨骼中优于基于fsr的GED。这些发现支持了病理步态个体实时外骨骼控制和步态评估的进一步发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.40
自引率
2.90%
发文量
65
审稿时长
27 weeks
期刊介绍: The IEEE Journal of Translational Engineering in Health and Medicine is an open access product that bridges the engineering and clinical worlds, focusing on detailed descriptions of advanced technical solutions to a clinical need along with clinical results and healthcare relevance. The journal provides a platform for state-of-the-art technology directions in the interdisciplinary field of biomedical engineering, embracing engineering, life sciences and medicine. A unique aspect of the journal is its ability to foster a collaboration between physicians and engineers for presenting broad and compelling real world technological and engineering solutions that can be implemented in the interest of improving quality of patient care and treatment outcomes, thereby reducing costs and improving efficiency. The journal provides an active forum for clinical research and relevant state-of the-art technology for members of all the IEEE societies that have an interest in biomedical engineering as well as reaching out directly to physicians and the medical community through the American Medical Association (AMA) and other clinical societies. The scope of the journal includes, but is not limited, to topics on: Medical devices, healthcare delivery systems, global healthcare initiatives, and ICT based services; Technological relevance to healthcare cost reduction; Technology affecting healthcare management, decision-making, and policy; Advanced technical work that is applied to solving specific clinical needs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书