Comparison of commercial 1Tx32Rx vs. 8Tx32Rx head coils for routine 7T neuroimaging.

IF 2.5
Frontiers in neuroimaging Pub Date : 2026-03-25 eCollection Date: 2026-01-01 DOI:10.3389/fnimg.2026.1736950
Carina Graf, Belinda Ding, Catarina Rua, Krzysztof Klodowski, Christopher T Rodgers
{"title":"Comparison of commercial 1Tx32Rx vs. 8Tx32Rx head coils for routine 7T neuroimaging.","authors":"Carina Graf, Belinda Ding, Catarina Rua, Krzysztof Klodowski, Christopher T Rodgers","doi":"10.3389/fnimg.2026.1736950","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Human 7T MRI systems are manufactured by three vendors (Siemens, Philips, and GE) who all provide equivalent head coils from the same 3rd party manufacturer. Furthermore, many 7T MRI sites have two head coils available for neuroimaging: a 1Tx32Rx head coil for conventional single-channel transmit imaging and an 8Tx32Rx head coil for parallel-transmit (pTx) imaging.</p><p><strong>Methods: </strong>We compared the performance of these coils in six healthy volunteers. All scans were done on a 7T MRI (MAGNETOM Terra, Siemens, Germany). We tested seven sequences in wide use at our centre: B<sub>0</sub> and B<sub>1</sub> <sup>+</sup> mapping, anatomical T<sub>1</sub>-weighted MP2RAGE, R<sub>2</sub>*-mapping, single-voxel spectroscopy (MRS), echo-planar imaging time series, and diffusion tensor imaging (DTI). Sequences were run unmodified and without any pTx pulses.</p><p><strong>Results: </strong>Data quality is comparable for both coils. The 8Tx32Rx coil had improved B<sub>1</sub> <sup>+</sup> in inferior brain regions, enhanced spinal cord visibility in the cervical spine on anatomical MP2RAGE, higher SNR in MRS of the brainstem, and more defined fitted white matter tracts in the DTI images. All sequences showed acceptable data quality with the 8Tx32Rx coil.</p><p><strong>Conclusion: </strong>It is reasonable to substitute the 8Tx32Rx coil for the 1Tx32Rx coil for standard neuroimaging protocols. This will enable advanced parallel transmit sequences to be added to protocols with minimal disruption.</p>","PeriodicalId":73094,"journal":{"name":"Frontiers in neuroimaging","volume":"5 ","pages":"1736950"},"PeriodicalIF":2.5000,"publicationDate":"2026-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13056848/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in neuroimaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fnimg.2026.1736950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Human 7T MRI systems are manufactured by three vendors (Siemens, Philips, and GE) who all provide equivalent head coils from the same 3rd party manufacturer. Furthermore, many 7T MRI sites have two head coils available for neuroimaging: a 1Tx32Rx head coil for conventional single-channel transmit imaging and an 8Tx32Rx head coil for parallel-transmit (pTx) imaging.

Methods: We compared the performance of these coils in six healthy volunteers. All scans were done on a 7T MRI (MAGNETOM Terra, Siemens, Germany). We tested seven sequences in wide use at our centre: B0 and B1 + mapping, anatomical T1-weighted MP2RAGE, R2*-mapping, single-voxel spectroscopy (MRS), echo-planar imaging time series, and diffusion tensor imaging (DTI). Sequences were run unmodified and without any pTx pulses.

Results: Data quality is comparable for both coils. The 8Tx32Rx coil had improved B1 + in inferior brain regions, enhanced spinal cord visibility in the cervical spine on anatomical MP2RAGE, higher SNR in MRS of the brainstem, and more defined fitted white matter tracts in the DTI images. All sequences showed acceptable data quality with the 8Tx32Rx coil.

Conclusion: It is reasonable to substitute the 8Tx32Rx coil for the 1Tx32Rx coil for standard neuroimaging protocols. This will enable advanced parallel transmit sequences to be added to protocols with minimal disruption.

商用1Tx32Rx与8Tx32Rx头线圈用于常规7T神经成像的比较。
人体7T MRI系统由三家供应商(西门子,飞利浦和GE)制造,他们都提供来自同一第三方制造商的等效头部线圈。此外,许多7T MRI部位有两个可用于神经成像的头线圈:用于传统单通道传输成像的1Tx32Rx头线圈和用于并行传输(pTx)成像的8Tx32Rx头线圈。方法:我们在6名健康志愿者身上比较了这些线圈的性能。所有扫描均在7T MRI (MAGNETOM Terra, Siemens, Germany)上完成。我们测试了本中心广泛使用的七种序列:B0和B1 +图谱、解剖t1加权MP2RAGE、R2*图谱、单体素光谱(MRS)、回波平面成像时间序列和扩散张量成像(DTI)。序列在未修改的情况下运行,没有任何pTx脉冲。结果:两种线圈的数据质量相当。8Tx32Rx线圈改善了下脑区的B1 +水平,增强了颈椎解剖MP2RAGE上的脊髓可见性,脑干MRS上的信噪比更高,DTI图像上的白质束更清晰。使用8Tx32Rx线圈,所有序列的数据质量均可接受。结论:用8Tx32Rx线圈代替1Tx32Rx线圈作为标准神经影像学方案是合理的。这将使先进的并行传输序列能够以最小的中断添加到协议中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书