{"title":"Thermal runaway-induced short-circuit arc in highly integrated lithium-ion battery systems: mechanisms, thresholds, and mitigation strategies.","authors":"Zhenxing Yu, Chuan Chen, Pengfei Zhao, Yantao Qiao, Yu Cao, Binwei He, Zhimin Liu","doi":"10.1038/s44172-026-00657-w","DOIUrl":null,"url":null,"abstract":"<p><p>Thermal runaway-induced short-circuit arc in battery cell blocks or modules pose severe risks to electric vehicle safety; Despite this risk, however, their failure mechanisms, path and safety thresholds remain insufficiently understood. This study addresses these gaps by investigating short-circuit arc in commercial battery systems. Three short-circuit arc modes (case-to-case, case-to-busbar, and busbar-to-busbar) and corresponding failure paths were identified, with the case-to-case mode confirmed as the most hazardous. Experimental characterization reveals three phenomena during the case-to-case mode: weak Joule heating, intrinsic breakdown, and thermal breakdown with temperatures exceeding 1400 °C under 117 V and 7.2 mm, capable of triggering adjacent cell thermal runaway. A quadratic correlation between the critical breakdown voltage and electrode spacing was established, and a risk map was proposed. This study clarifies the mechanisms of thermal runaway-induced short-circuit arc, providing a quantitative safety design tool for highly integrated/high-voltage battery systems.</p>","PeriodicalId":72644,"journal":{"name":"Communications engineering","volume":" ","pages":""},"PeriodicalIF":7.0000,"publicationDate":"2026-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13234359/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Communications engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s44172-026-00657-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Thermal runaway-induced short-circuit arc in battery cell blocks or modules pose severe risks to electric vehicle safety; Despite this risk, however, their failure mechanisms, path and safety thresholds remain insufficiently understood. This study addresses these gaps by investigating short-circuit arc in commercial battery systems. Three short-circuit arc modes (case-to-case, case-to-busbar, and busbar-to-busbar) and corresponding failure paths were identified, with the case-to-case mode confirmed as the most hazardous. Experimental characterization reveals three phenomena during the case-to-case mode: weak Joule heating, intrinsic breakdown, and thermal breakdown with temperatures exceeding 1400 °C under 117 V and 7.2 mm, capable of triggering adjacent cell thermal runaway. A quadratic correlation between the critical breakdown voltage and electrode spacing was established, and a risk map was proposed. This study clarifies the mechanisms of thermal runaway-induced short-circuit arc, providing a quantitative safety design tool for highly integrated/high-voltage battery systems.