{"title":"Development of a micro separation and analysis system for uranyl ions composed of microplug extraction and liquid scintillation detection","authors":"Xinyi Qian, Naoki Shitara, Naokazu Idota, Takehiko Tsukahara","doi":"10.1007/s44211-026-00887-0","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The efficient separation and analysis of alpha-emitting radionuclides, which will reduce environmental and radiation workers’ workloads, is of growing importance in the conducting of safe and long-term nuclear decommissioning and environmental assessments. This study developed a novel analytical system comprising micro-extraction and liquid scintillation counting (LSC), capable of rapidly and simply analyzing alpha nuclides in small amounts of samples. Bulk extractions and micro-extractions of UO<sub>2</sub><sup>2+</sup> were performed using two types of extractive liquid scintillators containing bis(2-ethylhexyl) phosphate (HDEHP) and <i>N</i>,<i>N</i>,<i>N</i>′,<i>N</i>′-tetra-octyldiglycolamide (TODGA) ligands. The UO<sub>2</sub><sup>2+</sup> extraction rates were evaluated through inductively coupled plasma-optical emission spectrometry (ICP-OES) and LSC measurements. When measuring LSC spectra of the bulk-extracted organic scintillator phases, peaks assigned those of <sup>238</sup>U and <sup>234</sup>U isotopes were clearly observed. The peak intensities and counting rates increased linearly with increasing UO<sub>2</sub><sup>2+</sup> concentrations, confirming that the UO<sub>2</sub><sup>2+</sup> extraction rates determined from LSC measurements agreed well with those from ICP-OES. From the LSC spectra and counting rates of micro-extracted samples, it was confirmed that the HDEHP-type extractive scintillator achieved 100% extraction of UO<sub>2</sub><sup>2+</sup> within 20 s in the lower HNO<sub>3</sub> concentration ranges, which was more than 90 times faster than bulk extraction (30 min), and that quantitative analysis of uranium using LSC was feasible up to 3 M HNO<sub>3</sub>. The results demonstrate that the microfluidic-LSC approach has significant potential as an advanced separation−analysis method. It enables direct measurements of alpha-emitting radionuclides in organic phases without additional operations such as pretreatment and back-extraction.</p>\n <span>AbstractSection</span>\n Graphical abstract\n <div><figure><div><div><picture><source><img></source></picture></div></div></figure></div>\n \n </div>","PeriodicalId":7802,"journal":{"name":"Analytical Sciences","volume":"42 7","pages":"645 - 652"},"PeriodicalIF":2.0000,"publicationDate":"2026-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Sciences","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s44211-026-00887-0","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The efficient separation and analysis of alpha-emitting radionuclides, which will reduce environmental and radiation workers’ workloads, is of growing importance in the conducting of safe and long-term nuclear decommissioning and environmental assessments. This study developed a novel analytical system comprising micro-extraction and liquid scintillation counting (LSC), capable of rapidly and simply analyzing alpha nuclides in small amounts of samples. Bulk extractions and micro-extractions of UO22+ were performed using two types of extractive liquid scintillators containing bis(2-ethylhexyl) phosphate (HDEHP) and N,N,N′,N′-tetra-octyldiglycolamide (TODGA) ligands. The UO22+ extraction rates were evaluated through inductively coupled plasma-optical emission spectrometry (ICP-OES) and LSC measurements. When measuring LSC spectra of the bulk-extracted organic scintillator phases, peaks assigned those of 238U and 234U isotopes were clearly observed. The peak intensities and counting rates increased linearly with increasing UO22+ concentrations, confirming that the UO22+ extraction rates determined from LSC measurements agreed well with those from ICP-OES. From the LSC spectra and counting rates of micro-extracted samples, it was confirmed that the HDEHP-type extractive scintillator achieved 100% extraction of UO22+ within 20 s in the lower HNO3 concentration ranges, which was more than 90 times faster than bulk extraction (30 min), and that quantitative analysis of uranium using LSC was feasible up to 3 M HNO3. The results demonstrate that the microfluidic-LSC approach has significant potential as an advanced separation−analysis method. It enables direct measurements of alpha-emitting radionuclides in organic phases without additional operations such as pretreatment and back-extraction.
期刊介绍:
Analytical Sciences is an international journal published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods.
This publication is supported in part by the Grant-in-Aid for Publication of Scientific Research Result of the Japanese Ministry of Education, Culture, Sports, Science and Technology.