Ex Vivo Pullout Strength of Locking and Cortical Screws in the Femur and Tibiotarsus of the Pekin Duck (Anas platyrhynchos domesticus).

IF 0.5 4区 农林科学 Q3 VETERINARY SCIENCES
Orr Cohen, Hamish R Baron, Ben C Stevenson, Daniel J Wills, Tian Wang, William R Walsh, Stephen M Fearnside, Melinda L Cowan
{"title":"Ex Vivo Pullout Strength of Locking and Cortical Screws in the Femur and Tibiotarsus of the Pekin Duck (<i>Anas platyrhynchos domesticus</i>).","authors":"Orr Cohen, Hamish R Baron, Ben C Stevenson, Daniel J Wills, Tian Wang, William R Walsh, Stephen M Fearnside, Melinda L Cowan","doi":"10.1647/AVIANMS-D-25-00017","DOIUrl":null,"url":null,"abstract":"<p><p>The development of smaller orthopedic plates and screws has facilitated their use in avian fracture repair. Avian bone differs from mammalian bone in its biomechanical properties due to adaptations for flight, necessitating avian-specific orthopedic biomechanical studies. Screw pullout strength has not been studied in avian bone. The aims of this study were to 1) compare the axial pullout strength of cortical and locking screw designs in the tibiotarsus and femur of the Pekin duck (<i>Anas platyrhynchos domesticus</i>) and 2) investigate the effects of sex and screw location in bone on screw pullout strength. Locking and cortical screws were inserted in 5 locations: the distal metaphysis, distal diaphysis, middiaphysis, proximal diaphysis, and proximal metaphysis of femora (n = 28) and tibiotarsi (n = 40) from 20 Pekin ducks. Screws were tested to failure in axial pullout and maximum force recorded. Data were analyzed by a linear mixed-effects model. There were no significant differences in screw pullout strength between locking and cortical screws or between sexes. On average, maximum force was highest at the middiaphysis in the femur and at the distal diaphysis of the tibiotarsus. These results suggest that when using 2.0-mm and 1.5-mm screws in avian femoral and tibiotarsal bones, respectively, screw positioning in denser diaphyseal regions may be more critical to screw pullout strength than the choice between cortical and locking screw designs.</p>","PeriodicalId":15102,"journal":{"name":"Journal of Avian Medicine and Surgery","volume":"40 1","pages":"39-45"},"PeriodicalIF":0.5000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Avian Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1647/AVIANMS-D-25-00017","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The development of smaller orthopedic plates and screws has facilitated their use in avian fracture repair. Avian bone differs from mammalian bone in its biomechanical properties due to adaptations for flight, necessitating avian-specific orthopedic biomechanical studies. Screw pullout strength has not been studied in avian bone. The aims of this study were to 1) compare the axial pullout strength of cortical and locking screw designs in the tibiotarsus and femur of the Pekin duck (Anas platyrhynchos domesticus) and 2) investigate the effects of sex and screw location in bone on screw pullout strength. Locking and cortical screws were inserted in 5 locations: the distal metaphysis, distal diaphysis, middiaphysis, proximal diaphysis, and proximal metaphysis of femora (n = 28) and tibiotarsi (n = 40) from 20 Pekin ducks. Screws were tested to failure in axial pullout and maximum force recorded. Data were analyzed by a linear mixed-effects model. There were no significant differences in screw pullout strength between locking and cortical screws or between sexes. On average, maximum force was highest at the middiaphysis in the femur and at the distal diaphysis of the tibiotarsus. These results suggest that when using 2.0-mm and 1.5-mm screws in avian femoral and tibiotarsal bones, respectively, screw positioning in denser diaphyseal regions may be more critical to screw pullout strength than the choice between cortical and locking screw designs.

北京鸭股骨和胫跗骨锁紧螺钉和皮质螺钉的离体拔出强度。
小型骨科钢板和螺钉的发展促进了它们在鸟类骨折修复中的应用。鸟类骨骼的生物力学特性不同于哺乳动物骨骼,这是由于鸟类对飞行的适应,因此有必要对鸟类进行特定的骨科生物力学研究。螺钉拔出强度尚未在鸟类骨中得到研究。本研究的目的是1)比较北京鸭(Anas platyrhynchos domesticus)胫跗骨和股骨皮质螺钉和锁定螺钉设计的轴向拔出强度;2)研究性别和螺钉在骨中的位置对螺钉拔出强度的影响。将锁定螺钉和皮质螺钉置入20只北京鸭的股骨干骺端远端、骨干远端、骨干中端、骨干近端和股骨干骺端近端(n = 28)和胫跗骨(n = 40) 5个位置。对螺钉进行轴向拔出失效试验,并记录最大拉力。数据分析采用线性混合效应模型。锁紧螺钉和皮质螺钉以及性别间的螺钉拔出强度无显著差异。平均而言,股骨中骨干和胫跗骨远端骨干的力最大。这些结果表明,当分别在禽类股骨和胫跗骨中使用2.0 mm和1.5 mm螺钉时,螺钉定位在更密集的骨干区域可能比选择皮质和锁定螺钉设计对螺钉拔出强度更重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Avian Medicine and Surgery
Journal of Avian Medicine and Surgery 农林科学-兽医学
CiteScore
0.90
自引率
0.00%
发文量
52
审稿时长
>36 weeks
期刊介绍: The Journal of Avian Medicine and Surgery is an international journal of the medicine and surgery of both captive and wild birds. Published materials include scientific articles, case reports, editorials, abstracts, new research, and book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书