{"title":"Multiplanar versus axial measurement of prostate lesion size: agreement and impact on PI-RADS v2.1 categorization and histopathologic correlation","authors":"Thitinan Chulroek, Ratchaya Ariyasaksakul","doi":"10.1007/s00261-026-05484-3","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To evaluate whether measurement of prostate lesion size on sagittal or coronal imaging planes influences PI-RADS v2.1 categorization and histopathologic correlation compared with axial measurement.</p><h3>Methods</h3><p>In this single-center retrospective study, 261 prostate lesions categorized as PI-RADS 4 or 5 underwent subsequent targeted MRI/TRUS fusion biopsy or prostatectomy. Lesion size was measured as maximal axial diameter (MAD) and maximal coronal or sagittal diameter (MCSD). Lesions were subsequently categorized according to PI-RADS v2.1 using these measurements. The agreement between MAD and MCSD was assessed using a Bland–Altman analysis. Measurement reliability and interobserver agreement were evaluated using intraclass correlation coefficients (ICC). Kappa statistics were used to assess agreement in PI-RADS categorization for clinically significant prostate cancer.</p><h3>Result</h3><p>Bland–Altman analysis demonstrated minimal bias and strong agreement between MAD and MCSD measurements for the whole prostate (mean difference 0.28 mm; 95% limits of agreement − 2.62 to 3.19 mm), with similar results in both the peripheral and transition zones. Intraclass correlation analysis showed excellent reliability between measurements (ICC = 0.93). Agreement in PI-RADS categorization between MAD and MCSD was almost perfect (κ = 0.931). Reclassification from PI-RADS 4 to 5 occurred in 1.74% of lesions when using MCSD, and all reclassified lesions demonstrated clinically significant prostate cancer on histopathology.</p><h3>Conclusion</h3><p>MAD and MCSD measurements of prostate lesion size demonstrate excellent agreement and highly concordant PI-RADS categorization. Although reclassification is uncommon, evaluation of the sagittal or coronal planes may provide additional value for selected lesions with craniocaudal elongation, where the maximal tumor extent may not be fully represented on axial images.</p></div>","PeriodicalId":7126,"journal":{"name":"Abdominal Radiology","volume":"51 10","pages":"5127 - 5135"},"PeriodicalIF":2.3000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Abdominal Radiology","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s00261-026-05484-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To evaluate whether measurement of prostate lesion size on sagittal or coronal imaging planes influences PI-RADS v2.1 categorization and histopathologic correlation compared with axial measurement.
Methods
In this single-center retrospective study, 261 prostate lesions categorized as PI-RADS 4 or 5 underwent subsequent targeted MRI/TRUS fusion biopsy or prostatectomy. Lesion size was measured as maximal axial diameter (MAD) and maximal coronal or sagittal diameter (MCSD). Lesions were subsequently categorized according to PI-RADS v2.1 using these measurements. The agreement between MAD and MCSD was assessed using a Bland–Altman analysis. Measurement reliability and interobserver agreement were evaluated using intraclass correlation coefficients (ICC). Kappa statistics were used to assess agreement in PI-RADS categorization for clinically significant prostate cancer.
Result
Bland–Altman analysis demonstrated minimal bias and strong agreement between MAD and MCSD measurements for the whole prostate (mean difference 0.28 mm; 95% limits of agreement − 2.62 to 3.19 mm), with similar results in both the peripheral and transition zones. Intraclass correlation analysis showed excellent reliability between measurements (ICC = 0.93). Agreement in PI-RADS categorization between MAD and MCSD was almost perfect (κ = 0.931). Reclassification from PI-RADS 4 to 5 occurred in 1.74% of lesions when using MCSD, and all reclassified lesions demonstrated clinically significant prostate cancer on histopathology.
Conclusion
MAD and MCSD measurements of prostate lesion size demonstrate excellent agreement and highly concordant PI-RADS categorization. Although reclassification is uncommon, evaluation of the sagittal or coronal planes may provide additional value for selected lesions with craniocaudal elongation, where the maximal tumor extent may not be fully represented on axial images.
期刊介绍:
Abdominal Radiology seeks to meet the professional needs of the abdominal radiologist by publishing clinically pertinent original, review and practice related articles on the gastrointestinal and genitourinary tracts and abdominal interventional and radiologic procedures. Case reports are generally not accepted unless they are the first report of a new disease or condition, or part of a special solicited section.
Reasons to Publish Your Article in Abdominal Radiology:
· Official journal of the Society of Abdominal Radiology (SAR)
· Published in Cooperation with:
European Society of Gastrointestinal and Abdominal Radiology (ESGAR)
European Society of Urogenital Radiology (ESUR)
Asian Society of Abdominal Radiology (ASAR)
· Efficient handling and Expeditious review
· Author feedback is provided in a mentoring style
· Global readership
· Readers can earn CME credits