Effect of speech recognition test presentation on cochlear implant user performance.

IF 0.9 Q4 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
CoDAS Pub Date : 2026-03-30 eCollection Date: 2026-01-01 DOI:10.1590/2317-1782/e20240247pt
Aline Faria de Sousa, Lucas Bevilacqua Alves da Costa, Rubens Vuono de Brito Neto
{"title":"Effect of speech recognition test presentation on cochlear implant user performance.","authors":"Aline Faria de Sousa, Lucas Bevilacqua Alves da Costa, Rubens Vuono de Brito Neto","doi":"10.1590/2317-1782/e20240247pt","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze and compare speech recognition performance in cochlear implant (CI) users assessed with a speech recognition test administered through monitored live voice (MLV) and recorded audio, both in quiet and in noise.</p><p><strong>Methods: </strong>This cross-sectional study included 48 participants who underwent medical history assessment, audiometry, and speech recognition testing under four conditions: MLV in quiet, recorded audio in quiet, MLV in noise, and recorded audio with noise. Statistical analyses were performed using nonparametric tests, adopting a 95% confidence interval and a significance level of p < 0.05.</p><p><strong>Results: </strong>The highest performance was observed in the MLV condition in quiet, although this condition also showed greater response variability, suggesting a potential influence of evaluator-related characteristics. Performance in the MLV-in-noise and recorded-audio-in-quiet conditions was comparable, indicating that noise in live speech has an impact similar to changing the presentation mode from live to recorded speech. The lowest performance was observed in the recorded-in-noise condition, indicating that the combined effect of background noise and the absence of acoustic cues inherent to live speech negatively affects auditory performance. Word-based and sentence-based analyses produced similar outcomes.</p><p><strong>Conclusion: </strong>Speech recognition performance in CI users is influenced by both presentation mode and background noise. These findings indicate that noise may be as detrimental as the transition from live to recorded speech, underscoring the importance of standardizing speech recognition test administration.</p>","PeriodicalId":46547,"journal":{"name":"CoDAS","volume":"38 2","pages":"e20240247"},"PeriodicalIF":0.9000,"publicationDate":"2026-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13075849/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CoDAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2317-1782/e20240247pt","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To analyze and compare speech recognition performance in cochlear implant (CI) users assessed with a speech recognition test administered through monitored live voice (MLV) and recorded audio, both in quiet and in noise.

Methods: This cross-sectional study included 48 participants who underwent medical history assessment, audiometry, and speech recognition testing under four conditions: MLV in quiet, recorded audio in quiet, MLV in noise, and recorded audio with noise. Statistical analyses were performed using nonparametric tests, adopting a 95% confidence interval and a significance level of p < 0.05.

Results: The highest performance was observed in the MLV condition in quiet, although this condition also showed greater response variability, suggesting a potential influence of evaluator-related characteristics. Performance in the MLV-in-noise and recorded-audio-in-quiet conditions was comparable, indicating that noise in live speech has an impact similar to changing the presentation mode from live to recorded speech. The lowest performance was observed in the recorded-in-noise condition, indicating that the combined effect of background noise and the absence of acoustic cues inherent to live speech negatively affects auditory performance. Word-based and sentence-based analyses produced similar outcomes.

Conclusion: Speech recognition performance in CI users is influenced by both presentation mode and background noise. These findings indicate that noise may be as detrimental as the transition from live to recorded speech, underscoring the importance of standardizing speech recognition test administration.

语音识别测试呈现对人工耳蜗使用者表现的影响。
目的:分析和比较人工耳蜗(CI)使用者在安静和噪音环境下的语音识别性能,通过监测实时语音(MLV)和录制音频进行语音识别测试。方法:本横断面研究纳入了48名参与者,他们在四种条件下进行了病史评估、听力测定和语音识别测试:安静时的MLV、安静时的录音、噪音时的MLV和噪音时的录音。统计学分析采用非参数检验,采用95%置信区间,显著性水平p < 0.05。结果:在安静的MLV条件下观察到最高的表现,尽管这种情况也表现出更大的反应变异性,表明评估者相关特征的潜在影响。mlv在噪音和录制的音频在安静条件下的表现是可比性的,这表明现场语音中的噪声的影响类似于将演示模式从现场改为录制的语音。在噪音录音条件下观察到最低的表现,表明背景噪音和缺乏现场语音固有的声音线索的综合影响对听觉表现产生负面影响。基于单词和基于句子的分析产生了相似的结果。结论:CI使用者的语音识别性能受呈现方式和背景噪声的影响。这些发现表明,噪音可能与从现场语音到录制语音的过渡一样有害,强调了标准化语音识别测试管理的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CoDAS
CoDAS AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-
CiteScore
0.90
自引率
12.50%
发文量
103
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书