Variability of Water T2 Times in Quantitative Muscle MRI: Considerations and Methodological Factors—A Narrative Review

Johanna Thomä, Lionel Butry, Johannes Forsting, Martijn Froeling, Lara Schlaffke
{"title":"Variability of Water T2 Times in Quantitative Muscle MRI: Considerations and Methodological Factors—A Narrative Review","authors":"Johanna Thomä,&nbsp;Lionel Butry,&nbsp;Johannes Forsting,&nbsp;Martijn Froeling,&nbsp;Lara Schlaffke","doi":"10.1002/rco2.70037","DOIUrl":null,"url":null,"abstract":"<p>Quantitative muscle imaging (qMRI) is an established method for detecting muscular changes, particularly in the diagnosis and follow-up of conditions as muscular injuries and neuromuscular diseases. While global T2 reflects all tissue components and cannot reliably indicate disease activity in fat-replaced muscles, water T2 times (wT2) can serve as a biomarker for inflammatory processes and intramuscular oedema and provide valuable information for disease activity. Proton-MR-spectroscopy (<sup>1</sup>H-MRS) is considered the reference standard for accurate wT2 measurements. However, its limited spatial coverage makes it unsuitable for whole-leg or whole-body analyses. T2-mapping offers an alternative by extracting wT2-values over larger regions. While monocentric assessment of individual changes is well established, comparing results across studies is difficult because of methodological differences. This narrative review summarizes 54 studies published between 1991 and 2025 reporting on wT2-values in healthy skeletal muscle. It evaluates the measurement methods used and their impact on measured values. This includes the use of <sup>1</sup>H-MRS as a reference, sequence parameters, fitting models and their correction methods, and inter-vendor variations. Finally, it gives recommendations for future studies investigating wT2 in muscle tissue. Since healthy muscle tissue is generally consistent across populations, similar wT2-values are expected between vendors. Compared with the <sup>1</sup>H-MRS ground truth of approximately 28.1 ms, reported wT2-values in literature range from 22.9 to 43.0 ms at 3 T (45 studies) and 27.6 to 41.9 ms at 1.5 T (nine studies), far exceeding the pathological sensitivity threshold of 1–2 ms. This review shows that, even with comparable methods and confounder correction, the observed differences in wT2-values exceed the pathological range. The review recommends including control groups and extended-phase-graph–based fitting with fat correction to improve comparability.</p>","PeriodicalId":73544,"journal":{"name":"JCSM rapid communications","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2026-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/rco2.70037","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JCSM rapid communications","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rco2.70037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Quantitative muscle imaging (qMRI) is an established method for detecting muscular changes, particularly in the diagnosis and follow-up of conditions as muscular injuries and neuromuscular diseases. While global T2 reflects all tissue components and cannot reliably indicate disease activity in fat-replaced muscles, water T2 times (wT2) can serve as a biomarker for inflammatory processes and intramuscular oedema and provide valuable information for disease activity. Proton-MR-spectroscopy (1H-MRS) is considered the reference standard for accurate wT2 measurements. However, its limited spatial coverage makes it unsuitable for whole-leg or whole-body analyses. T2-mapping offers an alternative by extracting wT2-values over larger regions. While monocentric assessment of individual changes is well established, comparing results across studies is difficult because of methodological differences. This narrative review summarizes 54 studies published between 1991 and 2025 reporting on wT2-values in healthy skeletal muscle. It evaluates the measurement methods used and their impact on measured values. This includes the use of 1H-MRS as a reference, sequence parameters, fitting models and their correction methods, and inter-vendor variations. Finally, it gives recommendations for future studies investigating wT2 in muscle tissue. Since healthy muscle tissue is generally consistent across populations, similar wT2-values are expected between vendors. Compared with the 1H-MRS ground truth of approximately 28.1 ms, reported wT2-values in literature range from 22.9 to 43.0 ms at 3 T (45 studies) and 27.6 to 41.9 ms at 1.5 T (nine studies), far exceeding the pathological sensitivity threshold of 1–2 ms. This review shows that, even with comparable methods and confounder correction, the observed differences in wT2-values exceed the pathological range. The review recommends including control groups and extended-phase-graph–based fitting with fat correction to improve comparability.

Abstract Image

定量肌肉MRI中水T2时间的可变性:考虑和方法学因素-叙述性回顾
定量肌肉成像(qMRI)是一种检测肌肉变化的既定方法,特别是在肌肉损伤和神经肌肉疾病的诊断和随访方面。虽然总T2反映了所有组织成分,不能可靠地指示脂肪替代肌肉的疾病活动,但水T2时间(wT2)可以作为炎症过程和肌肉内水肿的生物标志物,并为疾病活动提供有价值的信息。质子-磁共振光谱(1H-MRS)被认为是精确测量wT2的参考标准。然而,其有限的空间覆盖使其不适合全腿或全身分析。t2映射通过在更大的区域中提取wt2值提供了另一种选择。虽然对个体变化的单中心评估已经建立,但由于方法上的差异,比较不同研究的结果是困难的。本综述总结了1991年至2025年间发表的关于健康骨骼肌wt2值的54项研究。它评价所使用的测量方法及其对测量值的影响。这包括使用1H-MRS作为参考,序列参数,拟合模型及其校正方法,以及供应商之间的差异。最后,对未来肌肉组织中wT2的研究提出了建议。由于健康的肌肉组织在人群中通常是一致的,因此预计供应商之间的wt2值相似。文献报道的wt2值在3 T时为22.9 ~ 43.0 ms(45项研究),在1.5 T时为27.6 ~ 41.9 ms(9项研究),远远超过1 ~ 2 ms的病理敏感性阈值。本综述显示,即使采用可比方法和混杂校正,观察到的wt2值差异仍超过病理范围。该综述建议包括对照组和基于扩展相图的脂肪校正拟合,以提高可比性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书