Correction of Respiratory Motion in Free-Breathing DCE-MRI Using a Pilot-Tone Coil.

IF 2.8 4区 医学 Q2 BIOPHYSICS
Ruoxun Zi, Mario Bacher, Peter Speier, Hersh Chandarana, Riccardo Lattanzi, Kai Tobias Block
{"title":"Correction of Respiratory Motion in Free-Breathing DCE-MRI Using a Pilot-Tone Coil.","authors":"Ruoxun Zi, Mario Bacher, Peter Speier, Hersh Chandarana, Riccardo Lattanzi, Kai Tobias Block","doi":"10.1002/nbm.70278","DOIUrl":null,"url":null,"abstract":"<p><p>Respiratory motion poses a major challenge in abdominopelvic MRI and often leads to strong artifacts. Self-navigation techniques have been proposed for motion correction, allowing free-breathing examination. However, self-navigation methods typically fail to track respiratory motion for dynamic contrast-enhanced (DCE) scans due to concurrent signal changes caused by the contrast injection. In this study, we investigated the use of a pilot-tone (PT) transmitter integrated into the receive coil as an alternative approach for obtaining respiratory curves. The amplitude of the received PT signal gets modulated by respiratory motion due to changes in the coil load. A pipeline for extracting respiratory curves from the PT signal was developed and applied for motion-corrected free-breathing abdominal DCE-MRI. Validation experiments included real-time cine imaging and comparison with self-navigation for five late-phase liver scans. Dynamic experiments were performed for a liver DCE scan of one healthy volunteer and kidney DCE scans of 24 patients. A motion-weighted GRASP algorithm was used for reconstructing dynamic images. Quantitative metrics, including gradient entropy for individual images and the L2 norm of the temporal differences for each dynamic frame set, were calculated. Motion-weighted DCE GRASP reconstructions using PT-derived respiratory curves showed improved image sharpness, especially in regions such as the diaphragm, kidney boundaries, and vessels, as well as better temporal consistency compared to conventional GRASP reconstructions. These improvements were observed both qualitatively and quantitatively. This work demonstrates that the PT technique can accurately detect respiration during contrast injections, reducing motion blurring in free-breathing dynamic DCE-MRI. The proposed technique can be easily implemented in the clinical workflow by using a coil with an integrated PT transmitter and requires no external belts or sensors.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":"39 5","pages":"e70278"},"PeriodicalIF":2.8000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.70278","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Respiratory motion poses a major challenge in abdominopelvic MRI and often leads to strong artifacts. Self-navigation techniques have been proposed for motion correction, allowing free-breathing examination. However, self-navigation methods typically fail to track respiratory motion for dynamic contrast-enhanced (DCE) scans due to concurrent signal changes caused by the contrast injection. In this study, we investigated the use of a pilot-tone (PT) transmitter integrated into the receive coil as an alternative approach for obtaining respiratory curves. The amplitude of the received PT signal gets modulated by respiratory motion due to changes in the coil load. A pipeline for extracting respiratory curves from the PT signal was developed and applied for motion-corrected free-breathing abdominal DCE-MRI. Validation experiments included real-time cine imaging and comparison with self-navigation for five late-phase liver scans. Dynamic experiments were performed for a liver DCE scan of one healthy volunteer and kidney DCE scans of 24 patients. A motion-weighted GRASP algorithm was used for reconstructing dynamic images. Quantitative metrics, including gradient entropy for individual images and the L2 norm of the temporal differences for each dynamic frame set, were calculated. Motion-weighted DCE GRASP reconstructions using PT-derived respiratory curves showed improved image sharpness, especially in regions such as the diaphragm, kidney boundaries, and vessels, as well as better temporal consistency compared to conventional GRASP reconstructions. These improvements were observed both qualitatively and quantitatively. This work demonstrates that the PT technique can accurately detect respiration during contrast injections, reducing motion blurring in free-breathing dynamic DCE-MRI. The proposed technique can be easily implemented in the clinical workflow by using a coil with an integrated PT transmitter and requires no external belts or sensors.

使用导音线圈校正自由呼吸dce mri中的呼吸运动。
呼吸运动是腹部骨盆MRI的主要挑战,经常导致强烈的伪影。自我导航技术已被提出用于运动矫正,允许自由呼吸检查。然而,由于注射造影剂引起的同步信号变化,自我导航方法通常无法跟踪动态对比增强(DCE)扫描的呼吸运动。在这项研究中,我们研究了将导音(PT)发射器集成到接收线圈中作为获得呼吸曲线的替代方法的使用。由于线圈负载的变化,接收到的PT信号的幅度被呼吸运动调制。开发了一种从PT信号中提取呼吸曲线的管道,并将其应用于运动校正的自由呼吸腹部DCE-MRI。验证实验包括实时电影成像和与5次晚期肝脏扫描的自我导航比较。对1名健康志愿者的肝脏DCE扫描和24名患者的肾脏DCE扫描进行了动态实验。采用运动加权抓取算法重建动态图像。计算定量指标,包括单个图像的梯度熵和每个动态帧集的时间差异的L2范数。使用pt衍生呼吸曲线的运动加权DCE GRASP重建显示出更高的图像清晰度,特别是在膈肌、肾脏边界和血管等区域,与传统的GRASP重建相比,其时间一致性更好。这些改进在定性和定量上都得到了观察。这项工作表明,PT技术可以准确地检测造影剂注射期间的呼吸,减少自由呼吸动态dce mri的运动模糊。所提出的技术可以很容易地在临床工作流程中实施,通过使用集成PT发射器的线圈,不需要外部皮带或传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书