Potassium Reference Intervals: A Need for Separate Reference Intervals for Serum and Plasma.

IF 2.3 Q3 MEDICAL LABORATORY TECHNOLOGY
Glen L Hortin, Joseph Leonard, Claude Bassil
{"title":"Potassium Reference Intervals: A Need for Separate Reference Intervals for Serum and Plasma.","authors":"Glen L Hortin, Joseph Leonard, Claude Bassil","doi":"10.1093/jalm/jfag029","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate potassium measurements are clinically important because life-threatening arrhythmias can occur at high or low potassium levels. Even mild dyskalemia is associated with adverse clinical outcomes. However, preanalytical factors and varying specimen types-serum, plasma, and whole blood-pose challenges in accurately measuring potassium, establishing reference intervals (RIs), and interpreting the results.</p><p><strong>Methods: </strong>Adult RIs for potassium were acquired from 60 laboratory directories. The distribution of plasma potassium values at a cancer center and effects of applying different RIs were evaluated.</p><p><strong>Results: </strong>Surveyed laboratories have 14 different RIs for serum potassium and, usually, the same RI for serum and plasma. Only 4 laboratories had different serum and plasma RIs. Applying common serum RIs to plasma measurements markedly affected the proportions of patient results outside the RI.</p><p><strong>Discussion: </strong>Although potassium measurements are relatively well standardized, laboratory RIs for potassium vary considerably. Most laboratories use the same RI for serum and plasma potassium, although serum and plasma measurements usually differ by 0.2-0.4 mmol/L, exceeding acceptable limits for bias. Consequently, serum-derived RIs are suboptimal RIs for plasma. Testing of plasma specimens is common in acute care settings, but most laboratory RIs and clinical guidelines are based on serum measurements. Outcome studies show that there is a narrow optimal range for potassium levels and that outcomes improve with careful management of potassium levels. Separate RIs and clinical guideline values for plasma and serum potassium offer better assessment of potassium levels.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":" ","pages":"857-862"},"PeriodicalIF":2.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfag029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Accurate potassium measurements are clinically important because life-threatening arrhythmias can occur at high or low potassium levels. Even mild dyskalemia is associated with adverse clinical outcomes. However, preanalytical factors and varying specimen types-serum, plasma, and whole blood-pose challenges in accurately measuring potassium, establishing reference intervals (RIs), and interpreting the results.

Methods: Adult RIs for potassium were acquired from 60 laboratory directories. The distribution of plasma potassium values at a cancer center and effects of applying different RIs were evaluated.

Results: Surveyed laboratories have 14 different RIs for serum potassium and, usually, the same RI for serum and plasma. Only 4 laboratories had different serum and plasma RIs. Applying common serum RIs to plasma measurements markedly affected the proportions of patient results outside the RI.

Discussion: Although potassium measurements are relatively well standardized, laboratory RIs for potassium vary considerably. Most laboratories use the same RI for serum and plasma potassium, although serum and plasma measurements usually differ by 0.2-0.4 mmol/L, exceeding acceptable limits for bias. Consequently, serum-derived RIs are suboptimal RIs for plasma. Testing of plasma specimens is common in acute care settings, but most laboratory RIs and clinical guidelines are based on serum measurements. Outcome studies show that there is a narrow optimal range for potassium levels and that outcomes improve with careful management of potassium levels. Separate RIs and clinical guideline values for plasma and serum potassium offer better assessment of potassium levels.

钾参考区间:血清和血浆需要单独的参考区间。
背景:准确的钾测量在临床上很重要,因为在高或低钾水平时都可能发生危及生命的心律失常。即使是轻微的钾血症也与不良的临床结果相关。然而,分析前因素和不同的标本类型(血清、血浆和全血)对准确测量钾、建立参考区间(RIs)和解释结果提出了挑战。方法:从60个实验室目录中获取成人钾的RIs。评价了某癌症中心血浆钾值的分布及应用不同RIs的效果。结果:调查实验室的血清钾有14种不同的RI,通常血清和血浆的RI是相同的。只有4个实验室血清和血浆RIs存在差异。将普通血清RIs应用于血浆测量显著影响了患者在RI之外结果的比例。讨论:虽然钾的测量相对标准化,但钾的实验室RIs差异很大。大多数实验室对血清和血浆钾使用相同的RI,尽管血清和血浆测量值通常相差0.2-0.4 mmol/L,超出了可接受的偏差限度。因此,血清衍生的RIs不是血浆的最佳RIs。血浆标本检测在急性护理环境中很常见,但大多数实验室RIs和临床指南都是基于血清测量。结果研究表明,钾水平的最佳范围很窄,仔细管理钾水平可以改善结果。单独的RIs和血浆和血清钾的临床指导值可以更好地评估钾水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书