Image-based modeling of individual far-field resistance in cochlear implant recipients.

IF 4.2
Benjamin Bircher, Stephan Schraivogel, Philipp Aebischer, Marco D Caversaccio, Wilhelm Wimmer, Stefan Weder
{"title":"Image-based modeling of individual far-field resistance in cochlear implant recipients.","authors":"Benjamin Bircher, Stephan Schraivogel, Philipp Aebischer, Marco D Caversaccio, Wilhelm Wimmer, Stefan Weder","doi":"10.1016/j.zemedi.2026.03.012","DOIUrl":null,"url":null,"abstract":"<p><p>Cochlear implants (CIs) are effective auditory neuroprostheses, but performance varies across patients. One factor contributing to this variability is the spread of electrical current within the cochlea, which reduces spectral resolution and limits speech understanding. Far-field resistance, which can be measured directly, reflects current flow through perilymph and surrounding tissue and may be influenced by patient-specific anatomy. We developed an image-based model to automatically predict far-field resistance profiles using patient-specific cochlear geometries derived from preoperative computed tomography (CT) scans. In a retrospective analysis of 36 CI cases, surface meshes of the scala tympani and scala vestibuli were automatically segmented. Electrode positions were extracted from postoperative CT scans for validation purposes. Far-field resistance was estimated by computing cumulative resistances along longitudinal pathways within the scalae. The model systematically overestimated resistances by up to a factor of 5.2 depending on electrode insertion depth. After systematic deviation correction, high agreement with measured values was achieved in 33 of 36 subjects (root mean square error less than 0.15 kΩ, Spearman ρ=0.83), while outliers suggested atypical current spread due to electrode positioning, tissue contact, or alternative conductive pathways. The image-based model captured subject-specific resistance trends and apical electrode variability better than a group-average reference, though basal predictions were affected by near-field contributions and segmentation uncertainties. These results demonstrate that individualized CT-based modeling can approximate far-field resistance profiles and could enable further research on the interpretation of intracochlear current flow. Our approach could use routinely acquired preoperative imaging to complement the measured resistance, enabling the interpretation of inter-subject variability and the identification of atypical profiles potentially related to electrode positioning or tissue changes. The approach could be integrated into clinical workflows and extended with advanced modeling techniques to support surgical planning, postoperative monitoring, and device programming, linking anatomical imaging with functional impedance assessment.</p>","PeriodicalId":101315,"journal":{"name":"Zeitschrift fur medizinische Physik","volume":" ","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2026-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur medizinische Physik","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.zemedi.2026.03.012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Cochlear implants (CIs) are effective auditory neuroprostheses, but performance varies across patients. One factor contributing to this variability is the spread of electrical current within the cochlea, which reduces spectral resolution and limits speech understanding. Far-field resistance, which can be measured directly, reflects current flow through perilymph and surrounding tissue and may be influenced by patient-specific anatomy. We developed an image-based model to automatically predict far-field resistance profiles using patient-specific cochlear geometries derived from preoperative computed tomography (CT) scans. In a retrospective analysis of 36 CI cases, surface meshes of the scala tympani and scala vestibuli were automatically segmented. Electrode positions were extracted from postoperative CT scans for validation purposes. Far-field resistance was estimated by computing cumulative resistances along longitudinal pathways within the scalae. The model systematically overestimated resistances by up to a factor of 5.2 depending on electrode insertion depth. After systematic deviation correction, high agreement with measured values was achieved in 33 of 36 subjects (root mean square error less than 0.15 kΩ, Spearman ρ=0.83), while outliers suggested atypical current spread due to electrode positioning, tissue contact, or alternative conductive pathways. The image-based model captured subject-specific resistance trends and apical electrode variability better than a group-average reference, though basal predictions were affected by near-field contributions and segmentation uncertainties. These results demonstrate that individualized CT-based modeling can approximate far-field resistance profiles and could enable further research on the interpretation of intracochlear current flow. Our approach could use routinely acquired preoperative imaging to complement the measured resistance, enabling the interpretation of inter-subject variability and the identification of atypical profiles potentially related to electrode positioning or tissue changes. The approach could be integrated into clinical workflows and extended with advanced modeling techniques to support surgical planning, postoperative monitoring, and device programming, linking anatomical imaging with functional impedance assessment.

人工耳蜗受者个体远场电阻的图像建模。
人工耳蜗(CIs)是一种有效的听觉神经假体,但不同患者的表现不同。造成这种差异的一个因素是耳蜗内电流的扩散,这会降低频谱分辨率,限制语音理解。远场电阻,可以直接测量,反映电流通过淋巴管周围和周围组织,并可能受到患者特定解剖结构的影响。我们开发了一种基于图像的模型,通过术前计算机断层扫描(CT)获得的患者特定耳蜗几何形状来自动预测远场电阻分布。回顾性分析36例CI病例,自动分割中鼓室和前庭阶梯的表面网格。为了验证目的,从术后CT扫描中提取电极位置。通过计算尺度内纵向路径的累积电阻来估计远场电阻。根据电极插入深度的不同,该模型系统地高估了高达5.2倍的电阻。经过系统偏差校正,36名受试者中有33名与测量值高度吻合(均方根误差小于0.15 kΩ, Spearman ρ=0.83),而异常值表明由于电极定位、组织接触或替代导电途径导致的非典型电流扩散。尽管基础预测受到近场贡献和分割不确定性的影响,但基于图像的模型比群体平均参考更好地捕获了受试者特定的电阻趋势和顶端电极变化。这些结果表明,基于ct的个性化建模可以近似地模拟远场电阻分布,并可以进一步研究耳蜗内电流的解释。我们的方法可以使用常规的术前成像来补充测量的电阻,从而解释受试者间的变异性,并识别可能与电极定位或组织变化相关的非典型特征。该方法可以集成到临床工作流程中,并通过先进的建模技术进行扩展,以支持手术计划、术后监测和设备编程,将解剖成像与功能阻抗评估联系起来。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书