{"title":"Comparative analysis of accuracy and safety in guided versus freehand lateral-to-medial humeral transcondylar drilling.","authors":"Rodrigo Rosa, Julie Hunt, Michael D Schlicksup, Collin A Wolff","doi":"10.1111/vsu.70097","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the performance of three guided humeral transcondylar drilling techniques and the freehand drilling technique based on anatomical landmarks.</p><p><strong>Study design: </strong>Randomized block design ex vivo study.</p><p><strong>Sample population: </strong>Canine cadavers (n = 48; 96 elbows).</p><p><strong>Methods: </strong>Elbows were scanned using computed tomography (CT) to manufacture patient-specific three-dimensional (3D)-printed drill guides (3D-PDG) and were randomly assigned to one of four groups: universal aiming device (UAD), fluoroscopy-assisted drilling (FAD), 3D-PDG, and freehand drilling (FHD) performed by two board-certified surgeons. All elbows were CT scanned. Drilled tunnels (DT) were compared with an optimal drilling axis (ODA). Outcome measures included drilling time, DT entry and exit point translations, angulation, distance to the articular surface, and joint infringement.</p><p><strong>Results: </strong>Drilling technique influenced both entry and exit point translation. Freehand drilling was the fastest and safest method (0% joint infringement). The UAD exhibited the highest incidence of joint infringement (26.1%), followed by 3D-PDG (21.7%) and FAD (4.2%). Most joint infringements were caused by unacceptable (>10°) craniocaudal or proximodistal DT angulation.</p><p><strong>Conclusion: </strong>When performed by experienced surgeons, FHD is accurate and safe, and may outperform guided techniques. Laterally applied 3D-PDG necessitates specific design modifications to improve stability, as well as surgeon training and feedback. The UAD technique may be adversely affected by the lack of a surgical assistant and by limb position. Fluoroscopy-assisted drilling is accurate, but it results in a longer procedure time and requires equipment that may not be readily accessible.</p><p><strong>Clinical significance: </strong>Experienced surgeons can reliably perform FHD utilizing anatomical landmarks with satisfactory accuracy for humeral condylar drilling.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":"885-897"},"PeriodicalIF":1.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13360753/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.70097","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare the performance of three guided humeral transcondylar drilling techniques and the freehand drilling technique based on anatomical landmarks.

Study design: Randomized block design ex vivo study.

Sample population: Canine cadavers (n = 48; 96 elbows).

Methods: Elbows were scanned using computed tomography (CT) to manufacture patient-specific three-dimensional (3D)-printed drill guides (3D-PDG) and were randomly assigned to one of four groups: universal aiming device (UAD), fluoroscopy-assisted drilling (FAD), 3D-PDG, and freehand drilling (FHD) performed by two board-certified surgeons. All elbows were CT scanned. Drilled tunnels (DT) were compared with an optimal drilling axis (ODA). Outcome measures included drilling time, DT entry and exit point translations, angulation, distance to the articular surface, and joint infringement.

Results: Drilling technique influenced both entry and exit point translation. Freehand drilling was the fastest and safest method (0% joint infringement). The UAD exhibited the highest incidence of joint infringement (26.1%), followed by 3D-PDG (21.7%) and FAD (4.2%). Most joint infringements were caused by unacceptable (>10°) craniocaudal or proximodistal DT angulation.

Conclusion: When performed by experienced surgeons, FHD is accurate and safe, and may outperform guided techniques. Laterally applied 3D-PDG necessitates specific design modifications to improve stability, as well as surgeon training and feedback. The UAD technique may be adversely affected by the lack of a surgical assistant and by limb position. Fluoroscopy-assisted drilling is accurate, but it results in a longer procedure time and requires equipment that may not be readily accessible.

Clinical significance: Experienced surgeons can reliably perform FHD utilizing anatomical landmarks with satisfactory accuracy for humeral condylar drilling.

引导与徒手肱骨外侧至内侧经髁钻孔的准确性和安全性比较分析。
目的:比较三种肱骨经髁导向钻孔技术与基于解剖标志的徒手钻孔技术的性能。研究设计:随机区组设计离体研究。样本群体:犬尸体(n = 48; 96肘部)。方法:使用计算机断层扫描(CT)扫描肘部以制造患者特定的三维(3D)打印钻孔指南(3D- pdg),并随机分配到四组之一:通用瞄准装置(UAD),透视辅助钻孔(FAD), 3D- pdg和徒手钻孔(FHD)由两名委员会认证的外科医生进行。所有肘部均行CT扫描。将钻孔隧道(DT)与最佳钻孔轴(ODA)进行了比较。结果测量包括钻孔时间、DT进出点平移、成角、到关节面距离和关节侵犯。结果:钻孔技术对入口点和出口点平移均有影响。徒手钻孔是最快和最安全的方法(0%关节侵权)。联合侵权发生率最高的是UAD(26.1%),其次是3D-PDG(21.7%)和FAD(4.2%)。大多数关节侵犯是由不可接受的(bbb10°)颅-趾或近远端DT角度引起的。结论:在经验丰富的外科医生的指导下,FHD是准确和安全的,并且可能优于引导技术。横向应用3D-PDG需要特定的设计修改,以提高稳定性,以及外科医生的培训和反馈。UAD技术可能因缺乏手术辅助和肢体位置而受到不利影响。透视辅助钻孔是准确的,但它导致较长的程序时间,并需要设备,可能不容易获得。临床意义:经验丰富的外科医生可以可靠地利用解剖标志进行肱骨髁钻孔FHD,精度令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Surgery
Veterinary Surgery 农林科学-兽医学
CiteScore
3.40
自引率
22.20%
发文量
162
审稿时长
8-16 weeks
期刊介绍: Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations. It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书