Psychometric Evaluation of the Hypoparathyroidism Symptom Diary: Data from a Prospective Phase 3b/4 Study.

IF 2.4 Q3 HEALTH CARE SCIENCES & SERVICES
Patient Related Outcome Measures Pub Date : 2026-03-10 eCollection Date: 2025-01-01 DOI:10.2147/PROM.S539994
Suwei Wang, Nicholas J Rockwood, Stuart Yarr, Dane Korver, Felicia Castriota, Susan Martin, Olulade Ayodele
{"title":"Psychometric Evaluation of the Hypoparathyroidism Symptom Diary: Data from a Prospective Phase 3b/4 Study.","authors":"Suwei Wang, Nicholas J Rockwood, Stuart Yarr, Dane Korver, Felicia Castriota, Susan Martin, Olulade Ayodele","doi":"10.2147/PROM.S539994","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the psychometric properties of the disease-specific Hypoparathyroidism Symptom Diary (HypoPT-SD) patient-reported outcome (PRO) tool, which consists of a 7-item symptom subscale, a 4-item impact subscale, a single item for anxiety, and a single item for sadness or depression, using data from the BALANCE randomized, placebo-controlled Phase 3b/4 study (NCT03324880).</p><p><strong>Methods: </strong>Eligible patients had symptomatic hypoparathyroidism (HypoPT) at baseline and were aged 18-85 years (inclusive). Patients received recombinant human parathyroid hormone (1-84) or placebo. The HypoPT-SD was filled in daily; data recorded at baseline and Weeks 4, 12, and 26 (end of treatment [EOT]) were included in this analysis. Inter-item and item-total correlations were used to assess HypoPT-SD structure; Cronbach's coefficient α was used to analyze the internal consistency and reliability, and intraclass correlations were used to measure test-retest reliability. Construct validity was determined using correlational analyses between HypoPT-SD scores and scores from other conceptually similar PRO tools. Ability to detect change was assessed and thresholds for meaningful within-patient change were established.</p><p><strong>Results: </strong>The psychometric analysis population (N=93) was predominantly female (88.2%) and white (96.8%), with a mean age of 48.5 years. Inter-item correlations ranged from 0.35 to 0.85 at baseline and from 0.49 to 0.93 at EOT. Item-total correlations ranged from 0.57 to 0.83 at baseline and from 0.69 to 0.88 at EOT. Cronbach's α values at baseline were 0.90 (symptom subscale) and 0.88 (impact subscale). Intraclass correlation coefficients for both subscales in stable patients exceeded 0.70. Significant cross-sectional correlations were observed with most of the conceptually linked PRO tools analyzed, and HypoPT-SD scores were responsive to change. Potential changes of 1.5 (symptom subscale) and 0.8 (impact subscale) were determined as meaningful change thresholds for within-patient improvements.</p><p><strong>Conclusion: </strong>The HypoPT-SD is a reliable measure of key symptoms and impacts of HypoPT.</p>","PeriodicalId":19747,"journal":{"name":"Patient Related Outcome Measures","volume":"16 ","pages":"539994"},"PeriodicalIF":2.4000,"publicationDate":"2026-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12989284/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Related Outcome Measures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/PROM.S539994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the psychometric properties of the disease-specific Hypoparathyroidism Symptom Diary (HypoPT-SD) patient-reported outcome (PRO) tool, which consists of a 7-item symptom subscale, a 4-item impact subscale, a single item for anxiety, and a single item for sadness or depression, using data from the BALANCE randomized, placebo-controlled Phase 3b/4 study (NCT03324880).

Methods: Eligible patients had symptomatic hypoparathyroidism (HypoPT) at baseline and were aged 18-85 years (inclusive). Patients received recombinant human parathyroid hormone (1-84) or placebo. The HypoPT-SD was filled in daily; data recorded at baseline and Weeks 4, 12, and 26 (end of treatment [EOT]) were included in this analysis. Inter-item and item-total correlations were used to assess HypoPT-SD structure; Cronbach's coefficient α was used to analyze the internal consistency and reliability, and intraclass correlations were used to measure test-retest reliability. Construct validity was determined using correlational analyses between HypoPT-SD scores and scores from other conceptually similar PRO tools. Ability to detect change was assessed and thresholds for meaningful within-patient change were established.

Results: The psychometric analysis population (N=93) was predominantly female (88.2%) and white (96.8%), with a mean age of 48.5 years. Inter-item correlations ranged from 0.35 to 0.85 at baseline and from 0.49 to 0.93 at EOT. Item-total correlations ranged from 0.57 to 0.83 at baseline and from 0.69 to 0.88 at EOT. Cronbach's α values at baseline were 0.90 (symptom subscale) and 0.88 (impact subscale). Intraclass correlation coefficients for both subscales in stable patients exceeded 0.70. Significant cross-sectional correlations were observed with most of the conceptually linked PRO tools analyzed, and HypoPT-SD scores were responsive to change. Potential changes of 1.5 (symptom subscale) and 0.8 (impact subscale) were determined as meaningful change thresholds for within-patient improvements.

Conclusion: The HypoPT-SD is a reliable measure of key symptoms and impacts of HypoPT.

Abstract Image

Abstract Image

Abstract Image

甲状旁腺功能减退症状日记的心理测量评估:来自一项前瞻性3b/4期研究的数据
目的:评估疾病特异性甲状旁腺功能减退症状日记(HypoPT-SD)患者报告结果(PRO)工具的心理测量特性,该工具由7项症状量表、4项影响量表、单项焦虑和单项悲伤或抑郁组成,使用BALANCE随机、安慰剂对照3b/4期研究(NCT03324880)的数据。方法:符合条件的患者在基线时患有症状性甲状旁腺功能减退症(HypoPT),年龄在18-85岁(含)。患者接受重组人甲状旁腺激素(1-84)或安慰剂治疗。每日填写HypoPT-SD;基线和第4、12和26周(治疗结束[EOT])记录的数据包括在本分析中。项目间相关性和项目总相关性用于评估HypoPT-SD结构;采用Cronbach’s系数α分析内部一致性和信度,采用类内相关性测量重测信度。通过HypoPT-SD评分与其他概念相似的PRO工具评分之间的相关性分析来确定结构效度。评估检测变化的能力,并建立患者内部有意义变化的阈值。结果:心理测量分析人群(N=93)以女性(88.2%)和白人(96.8%)为主,平均年龄48.5岁。项目间相关性在基线时为0.35 ~ 0.85,在EOT时为0.49 ~ 0.93。项目-总相关性在基线时为0.57 - 0.83,在EOT时为0.69 - 0.88。Cronbach’s α基线值分别为0.90(症状分量表)和0.88(影响分量表)。在病情稳定的患者中,两个亚量表的类内相关系数均超过0.70。与大多数概念相关的PRO工具分析观察到显著的横断面相关性,HypoPT-SD评分对变化有反应。1.5(症状分量表)和0.8(影响分量表)的潜在变化被确定为患者内部改善的有意义的变化阈值。结论:HypoPT- sd是衡量HypoPT主要症状和影响的可靠指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Patient Related Outcome Measures
Patient Related Outcome Measures HEALTH CARE SCIENCES & SERVICES-
自引率
4.80%
发文量
27
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书