3D Radial Knee Imaging at 0.55 T: Simultaneous T1-T2 Mapping and Synthetic Contrast Generation in Under 4 min.

IF 2.8 4区 医学 Q2 BIOPHYSICS
Nicolás Garrido, Diego Pedraza, Carlos Castillo-Passi, Dabne Barrera, Claudia Prieto, René Botnar
{"title":"3D Radial Knee Imaging at 0.55 T: Simultaneous T<sub>1</sub>-T<sub>2</sub> Mapping and Synthetic Contrast Generation in Under 4 min.","authors":"Nicolás Garrido, Diego Pedraza, Carlos Castillo-Passi, Dabne Barrera, Claudia Prieto, René Botnar","doi":"10.1002/nbm.70265","DOIUrl":null,"url":null,"abstract":"<p><p>Quantitative MRI (T<sub>1</sub>-T<sub>2</sub>) has been shown to be useful for early diagnosis of osteoarthritis (OA) in the knee at 1.5 and 3 T. However, limited research has been performed at 0.55 T. In this study, we aim to develop and evaluate the feasibility of a 3D joint T<sub>1</sub>-T<sub>2</sub> mapping estimation and synthetic contrasts radial sequence for quantitative and anatomical water-fat imaging of the knee at 0.55 T. The proposed sequence consists of a free-running, 3D-golden angle radial trajectory preceded with inversion recovery and <math> <semantics> <mrow><msub><mi>T</mi> <mn>2</mn></msub> </mrow> <annotation>$$ {T}_2 $$</annotation></semantics> </math> -preparation pulses. Reconstruction of images is performed with parallel imaging and high-dimensional low-rank patch-based regularization. A water-fat separation technique is employed to obtain water and fat images, and T<sub>1</sub>-T<sub>2</sub> maps can be obtained for water and the echo images via Bloch-equation dictionary matching. The sequence was validated on a standardized phantom and in 16 healthy subjects. Phantom results are in good agreement with SE references, with biases of <math> <semantics><mrow><mn>1.78</mn></mrow> <annotation>$$ 1.78 $$</annotation></semantics> </math>  ms for <math> <semantics> <mrow><msub><mi>T</mi> <mn>1</mn></msub> </mrow> <annotation>$$ {T}_1 $$</annotation></semantics> </math> and <math> <semantics><mrow><mo>-</mo> <mn>0.23</mn></mrow> <annotation>$$ -0.23 $$</annotation></semantics> </math> ms for <math> <semantics> <mrow><msub><mi>T</mi> <mn>2</mn></msub> </mrow> <annotation>$$ {T}_2 $$</annotation></semantics> </math> . In vivo, the average mean in the articular cartilage was <math> <semantics> <mrow><msub><mi>T</mi> <mn>1</mn></msub> <mo>=</mo> <mn>460</mn> <mo>±</mo> <mn>45</mn></mrow> <annotation>$$ {T}_1=460\\pm 45 $$</annotation></semantics> </math> ms and <math> <semantics> <mrow><msub><mi>T</mi> <mn>2</mn></msub> <mo>=</mo> <mn>33</mn> <mo>±</mo> <mn>4</mn></mrow> <annotation>$$ {T}_2=33\\pm 4 $$</annotation></semantics> </math> ms, compared to <math> <semantics> <mrow><msub><mi>T</mi> <mn>1</mn></msub> <mo>=</mo> <mn>394</mn> <mo>±</mo> <mn>57</mn></mrow> <annotation>$$ {T}_1=394\\pm 57 $$</annotation></semantics> </math> ms, <math> <semantics> <mrow><msub><mi>T</mi> <mn>2</mn></msub> <mo>=</mo> <mn>44</mn> <mo>±</mo> <mn>10</mn></mrow> <annotation>$$ {T}_2=44\\pm 10 $$</annotation></semantics> </math> ms for the reference sequences. Synthetic contrast images produced with the sequence are comparable to the references in terms of contrast to noise ratio (CNR) and relative contrast metrics. The feasibility of 3D joint T<sub>1</sub>-T<sub>2</sub> mapping of the knee at 0.55 T in a single scan of ~3 min was demonstrated, showing promising results for efficient knee imaging. Studies in a larger cohort of patients with osteoarthritis at 0.55 T are now warranted.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":"39 4","pages":"e70265"},"PeriodicalIF":2.8000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.70265","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Quantitative MRI (T1-T2) has been shown to be useful for early diagnosis of osteoarthritis (OA) in the knee at 1.5 and 3 T. However, limited research has been performed at 0.55 T. In this study, we aim to develop and evaluate the feasibility of a 3D joint T1-T2 mapping estimation and synthetic contrasts radial sequence for quantitative and anatomical water-fat imaging of the knee at 0.55 T. The proposed sequence consists of a free-running, 3D-golden angle radial trajectory preceded with inversion recovery and T 2 $$ {T}_2 $$ -preparation pulses. Reconstruction of images is performed with parallel imaging and high-dimensional low-rank patch-based regularization. A water-fat separation technique is employed to obtain water and fat images, and T1-T2 maps can be obtained for water and the echo images via Bloch-equation dictionary matching. The sequence was validated on a standardized phantom and in 16 healthy subjects. Phantom results are in good agreement with SE references, with biases of 1.78 $$ 1.78 $$  ms for T 1 $$ {T}_1 $$ and - 0.23 $$ -0.23 $$ ms for T 2 $$ {T}_2 $$ . In vivo, the average mean in the articular cartilage was T 1 = 460 ± 45 $$ {T}_1=460\pm 45 $$ ms and T 2 = 33 ± 4 $$ {T}_2=33\pm 4 $$ ms, compared to T 1 = 394 ± 57 $$ {T}_1=394\pm 57 $$ ms, T 2 = 44 ± 10 $$ {T}_2=44\pm 10 $$ ms for the reference sequences. Synthetic contrast images produced with the sequence are comparable to the references in terms of contrast to noise ratio (CNR) and relative contrast metrics. The feasibility of 3D joint T1-T2 mapping of the knee at 0.55 T in a single scan of ~3 min was demonstrated, showing promising results for efficient knee imaging. Studies in a larger cohort of patients with osteoarthritis at 0.55 T are now warranted.

0.55 T的三维膝关节放射成像:在4分钟内同时进行T1-T2成像和合成造影剂生成。
定量MRI (T1-T2)已被证明对膝关节1.5和3t骨关节炎(OA)的早期诊断有用。然而,在0.55 T下进行的研究有限。在本研究中,我们的目标是开发和评估用于0.55 T时膝关节定量和解剖水脂肪成像的三维关节T1-T2映射估计和合成对比径向序列的可行性。所提出的序列包括自由运行的3d黄金角径向轨迹,前面有反演恢复和t2 $$ {T}_2 $$ -准备脉冲。利用并行成像和高维低秩补丁正则化技术对图像进行重构。采用水脂分离技术获得水和脂肪图像,通过Bloch-equation dictionary匹配得到水和回波图像的T1-T2图。该序列在一个标准的假体和16名健康受试者身上进行了验证。幻影结果与SE参考文献非常吻合,t1 $$ {T}_1 $$的偏差为1.78 $$ 1.78 $$ ms, t2 $$ {T}_2 $$的偏差为- 0.23 $$ -0.23 $$ ms。在体内,关节软骨内的平均t1 = 460±45 $$ {T}_1=460\pm 45 $$ ms, t2 = 33±4 $$ {T}_2=33\pm 4 $$ ms,而参考序列的平均t1 = 394±57 $$ {T}_1=394\pm 57 $$ ms, t2 = 44±10 $$ {T}_2=44\pm 10 $$ ms。合成对比图像产生的序列是相当的参考在对比度噪声比(CNR)和相对对比度指标。在0.55 T的单次扫描3分钟内对膝关节进行三维关节T1-T2成像的可行性被证明,显示出有效的膝关节成像结果。现在有必要在0.55 T骨关节炎患者中进行更大的队列研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书