{"title":"Development of infrared desolvation device for single cell element analysis using droplet sample injection inductively coupled plasma spectrometry","authors":"Kai Fukuchi, Syu Yamaji, Yuya Shimizu, Takashi Ohta, Akane Yaida, Yuki Maemoto, Motohide Aoki, Tomonari Umemura, Akitoshi Okino","doi":"10.1007/s44211-026-00888-z","DOIUrl":null,"url":null,"abstract":"<div><p>Microdroplet injection systems, which introduce single cells into an inductively coupled plasma by encapsulating them in droplets, have been developed by several research groups, including our group. In our laboratory, to improve the analytical sensitivity, a droplet desolvation system using a ribbon heater has achieved an approximately tenfold improvement in sensitivity. However, the desolvation throughput was limited to 100 Hz because of the low heat-transfer efficiency associated with indirect of indirect heating via heated gas. In this paper, a novel desolvation device using infrared radiation was developed to improve the desolvation throughput. Infrared radiation enables direct and efficient droplet heating. The developed device comprises a heating section and a cooling section. An infrared lamp with a luminous length of 140 mm was used in the heating section. Infrared radiation was focused on the flight axis of the droplets to enhance irradiation efficiency. The cooling section was placed downstream of the heating section to condense and remove vapor. With a power of 1000 W applied to the lamp and a carrier gas flow rate of 0.1 L min<sup>−1</sup>, the carrier gas temperatures at the bottom of the heating section remained below 71 °C for both argon and helium. Under these conditions, the cells remained intact without rupture. Helium exhibited superior throughput compared to argon and when the carrier gas flow rate was above 0.5 L min<sup>−1</sup>, the desolvation at a throughput of 1000 Hz could be achieved with an applied power of 150 W to the lamp.</p><h3>Graphical abstract</h3><div><figure><div><div><picture><source><img></source></picture><span>The alternative text for this image may have been generated using AI.</span></div></div></figure></div></div>","PeriodicalId":7802,"journal":{"name":"Analytical Sciences","volume":"42 5","pages":"319 - 328"},"PeriodicalIF":2.0000,"publicationDate":"2026-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s44211-026-00888-z.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Sciences","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s44211-026-00888-z","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Microdroplet injection systems, which introduce single cells into an inductively coupled plasma by encapsulating them in droplets, have been developed by several research groups, including our group. In our laboratory, to improve the analytical sensitivity, a droplet desolvation system using a ribbon heater has achieved an approximately tenfold improvement in sensitivity. However, the desolvation throughput was limited to 100 Hz because of the low heat-transfer efficiency associated with indirect of indirect heating via heated gas. In this paper, a novel desolvation device using infrared radiation was developed to improve the desolvation throughput. Infrared radiation enables direct and efficient droplet heating. The developed device comprises a heating section and a cooling section. An infrared lamp with a luminous length of 140 mm was used in the heating section. Infrared radiation was focused on the flight axis of the droplets to enhance irradiation efficiency. The cooling section was placed downstream of the heating section to condense and remove vapor. With a power of 1000 W applied to the lamp and a carrier gas flow rate of 0.1 L min−1, the carrier gas temperatures at the bottom of the heating section remained below 71 °C for both argon and helium. Under these conditions, the cells remained intact without rupture. Helium exhibited superior throughput compared to argon and when the carrier gas flow rate was above 0.5 L min−1, the desolvation at a throughput of 1000 Hz could be achieved with an applied power of 150 W to the lamp.
Graphical abstract
The alternative text for this image may have been generated using AI.
微滴注射系统,通过将单个细胞包裹在微滴中,将它们引入电感耦合等离子体中,已经由包括我们小组在内的几个研究小组开发出来。在我们的实验室中,为了提高分析灵敏度,使用带状加热器的液滴脱溶系统的灵敏度提高了大约十倍。然而,由于通过加热气体间接加热的低传热效率,溶解通量被限制在100 Hz。本文研制了一种利用红外辐射的新型脱溶装置,以提高脱溶通量。红外线辐射使液滴直接和有效加热。所开发的装置包括加热段和冷却段。加热段采用发光长度为140 mm的红外灯。将红外辐射聚焦在液滴的飞行轴上,以提高辐照效率。冷却段放置在加热段的下游,以冷凝和除去蒸汽。当灯的功率为1000w,载气流速为0.1 L min-1时,氩气和氦气在加热段底部的载气温度都保持在71℃以下。在这些条件下,细胞保持完整,没有破裂。氦气的通量优于氩气,当载气流速大于0.5 L min-1时,在150 W的功率下可以实现1000 Hz的溶解。
期刊介绍:
Analytical Sciences is an international journal published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods.
This publication is supported in part by the Grant-in-Aid for Publication of Scientific Research Result of the Japanese Ministry of Education, Culture, Sports, Science and Technology.