Dynamics of Glutamate and Glutamine Assessed Using MRS in Response to a Short Heat Pain Stimulation.

IF 2.8 4区 医学 Q2 BIOPHYSICS
Alexey Yakovlev, Elena Voronkova, Maxim Ublinskiy, Ilia Mel'nikov, Olga Bozhko, Sergey Varfolomeev, Tolibdzhon Akhadov
{"title":"Dynamics of Glutamate and Glutamine Assessed Using MRS in Response to a Short Heat Pain Stimulation.","authors":"Alexey Yakovlev, Elena Voronkova, Maxim Ublinskiy, Ilia Mel'nikov, Olga Bozhko, Sergey Varfolomeev, Tolibdzhon Akhadov","doi":"10.1002/nbm.70273","DOIUrl":null,"url":null,"abstract":"<p><p>It is assumed that the mechanism of changes in neurotransmitter levels measured by MRS in the short period of response to stimulation differs from the long one. According to compartmental shift hypothesis, the rapid increase in the MRS-measured level of neurotransmitters after event-related stimulus is due to their release from vesicles, and the subsequent decrease is due to their refilling. To test this hypothesis, we studied the concentration of the sum of glutamate and glutamine (Glx) in response to a short painful thermal stimulus. fMRI data and PRESS magnetic resonance spectra [echo time/repetition time = 35 ms/2000 ms] of an activated area in the left insular cortex of 26 subjects were acquired using a 3-T MR scanner. Stimulation was performed by presenting painful heat stimulus for 3 s, repeated with an interval of 7-9 s. The time course of Glx, N-acetylaspartate (NAA), and creatine (Cr) concentrations and the width and height of resonance lines were obtained with a nominal time resolution of 2 s. Changes in the linewidth and height of N-acetylaspartate and Cr signals were used to determine the BOLD effect. Seven subjects were excluded from analyses due to bad spectral quality or high Glx change in the dynamics. Because of nonreliable stimulation, analysis of response to stimulation was conducted in the two groups (less and more activated). In response to the activation, the Glx as the Glx/Cr ratio maximal increases were 4.2% ± 1.4% and 5.2% ± 1.4% (p < 0.05), respectively in 2 s after the establishing the stimulus temperature. Time courses of Cr and NAA signal width and height showed statistically significant decrease of Cr at 4 s after stimulus onset (-2.6% ± 0.8%, p = 0.03). The sensitivity of MRS to the BOLD effect was lower than that of the fMRI method. In the short response period, a short-term increase in the Glx level is observed. This result is in line with the compartmental shift hypothesis for short-term neurotransmitter dynamics, but further work is necessary to directly confirm this interpretation. Reliable detection of rapid increases in neurotransmitter levels following a short stimulus requires robust neural activation and minimal motion-related artifacts.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":"39 4","pages":"e70273"},"PeriodicalIF":2.8000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.70273","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

It is assumed that the mechanism of changes in neurotransmitter levels measured by MRS in the short period of response to stimulation differs from the long one. According to compartmental shift hypothesis, the rapid increase in the MRS-measured level of neurotransmitters after event-related stimulus is due to their release from vesicles, and the subsequent decrease is due to their refilling. To test this hypothesis, we studied the concentration of the sum of glutamate and glutamine (Glx) in response to a short painful thermal stimulus. fMRI data and PRESS magnetic resonance spectra [echo time/repetition time = 35 ms/2000 ms] of an activated area in the left insular cortex of 26 subjects were acquired using a 3-T MR scanner. Stimulation was performed by presenting painful heat stimulus for 3 s, repeated with an interval of 7-9 s. The time course of Glx, N-acetylaspartate (NAA), and creatine (Cr) concentrations and the width and height of resonance lines were obtained with a nominal time resolution of 2 s. Changes in the linewidth and height of N-acetylaspartate and Cr signals were used to determine the BOLD effect. Seven subjects were excluded from analyses due to bad spectral quality or high Glx change in the dynamics. Because of nonreliable stimulation, analysis of response to stimulation was conducted in the two groups (less and more activated). In response to the activation, the Glx as the Glx/Cr ratio maximal increases were 4.2% ± 1.4% and 5.2% ± 1.4% (p < 0.05), respectively in 2 s after the establishing the stimulus temperature. Time courses of Cr and NAA signal width and height showed statistically significant decrease of Cr at 4 s after stimulus onset (-2.6% ± 0.8%, p = 0.03). The sensitivity of MRS to the BOLD effect was lower than that of the fMRI method. In the short response period, a short-term increase in the Glx level is observed. This result is in line with the compartmental shift hypothesis for short-term neurotransmitter dynamics, but further work is necessary to directly confirm this interpretation. Reliable detection of rapid increases in neurotransmitter levels following a short stimulus requires robust neural activation and minimal motion-related artifacts.

利用MRS评估谷氨酸和谷氨酰胺对短热痛刺激的反应。
假设MRS测量的神经递质水平在刺激反应的短时间内变化的机制与长时间不同。根据房室移位假说,事件相关刺激后,mrs测量的神经递质水平快速升高是由于其从囊泡中释放,随后的下降是由于其再填充。为了验证这一假设,我们研究了在短时间疼痛热刺激下谷氨酸和谷氨酰胺(Glx)总和的浓度。使用3-T磁共振扫描仪获取26例受试者左岛皮层激活区fMRI数据和PRESS磁共振波谱[回声时间/重复时间= 35 ms/2000 ms]。以疼痛热刺激进行刺激,持续3 s,间隔7-9 s重复。以2 s的名义时间分辨率获得了Glx、n -乙酰天冬氨酸(NAA)和肌酸(Cr)浓度的时间过程以及共振谱线的宽度和高度。利用n -乙酰天冬氨酸和Cr信号的线宽和线高变化来确定BOLD效应。由于光谱质量差或动力学中Glx变化大,7名受试者被排除在分析之外。由于刺激不可靠,对两组的刺激反应进行分析(激活程度低和激活程度高)。激活后,Glx与Glx/Cr比值的最大增幅分别为4.2%±1.4%和5.2%±1.4% (p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书