Accuracy (Trueness and Precision) of the Calibrated Intraoral Scan Protocol: An In Vitro Comparison of Three Scan Calibrator Designs In an Edentulous Implant Model

IF 5.9 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Clinical Oral Implants Research Pub Date : 2026-06-04 Epub Date: 2026-03-14 DOI:10.1111/clr.70117
Shengtao Yang, Chenyi Zhang, Yan Bao, Shuo Wang, Lei Chi, Li Yue, Quan Yuan, Junying Li
{"title":"Accuracy (Trueness and Precision) of the Calibrated Intraoral Scan Protocol: An In Vitro Comparison of Three Scan Calibrator Designs In an Edentulous Implant Model","authors":"Shengtao Yang,&nbsp;Chenyi Zhang,&nbsp;Yan Bao,&nbsp;Shuo Wang,&nbsp;Lei Chi,&nbsp;Li Yue,&nbsp;Quan Yuan,&nbsp;Junying Li","doi":"10.1111/clr.70117","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To introduce a universal scan calibrator (SC) and to evaluate its accuracy in the calibrated intraoral scan protocol (CISP) by comparison with two previously published SCs.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Three SCs were evaluated on an edentulous implant model containing six scan bodies (SBs) positioned at the screw-retained abutment (SRA) level: (1) a universal SC with a C-shaped window (SC-CW), (2) an SC covering only the alveolar ridge (SC-R), and (3) an SC limited to the palatal region (SC-P). Each SC was attached to the model and scanned 10 times using an intraoral scanner (IOS). The intraoral scans were subsequently corrected using the corresponding desktop scans of the SCs as reference data. A desktop scan of the model served as the reference. The test scans were superimposed onto the reference scan by: (1) using all SBs to evaluate the overall fit, and (2) using the first and second SBs to simulate the virtual Sheffield test. Linear and angular deviations of SRAs were measured using Python scripts.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>When aligned by all SBs, all three groups exhibited significant improvements in trueness and linear precision following correction. In the virtual Sheffield test, no statistically significant differences were observed in post-correction trueness or angular precision at the ending SRA6. All three groups achieved clinically acceptable trueness and precision values following correction.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>All three SCs yielded clinically acceptable impressions after correction under in vitro conditions. The novel SC represents a promising approach for CISP; however, further in vivo clinical evidence is required.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"37 6","pages":"747-759"},"PeriodicalIF":5.9000,"publicationDate":"2026-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.70117","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.70117","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To introduce a universal scan calibrator (SC) and to evaluate its accuracy in the calibrated intraoral scan protocol (CISP) by comparison with two previously published SCs.

Materials and Methods

Three SCs were evaluated on an edentulous implant model containing six scan bodies (SBs) positioned at the screw-retained abutment (SRA) level: (1) a universal SC with a C-shaped window (SC-CW), (2) an SC covering only the alveolar ridge (SC-R), and (3) an SC limited to the palatal region (SC-P). Each SC was attached to the model and scanned 10 times using an intraoral scanner (IOS). The intraoral scans were subsequently corrected using the corresponding desktop scans of the SCs as reference data. A desktop scan of the model served as the reference. The test scans were superimposed onto the reference scan by: (1) using all SBs to evaluate the overall fit, and (2) using the first and second SBs to simulate the virtual Sheffield test. Linear and angular deviations of SRAs were measured using Python scripts.

Results

When aligned by all SBs, all three groups exhibited significant improvements in trueness and linear precision following correction. In the virtual Sheffield test, no statistically significant differences were observed in post-correction trueness or angular precision at the ending SRA6. All three groups achieved clinically acceptable trueness and precision values following correction.

Conclusions

All three SCs yielded clinically acceptable impressions after correction under in vitro conditions. The novel SC represents a promising approach for CISP; however, further in vivo clinical evidence is required.

Abstract Image

校准口内扫描方案的准确性(正确度和精密度):三种扫描校准器设计在无牙种植体模型中的体外比较。
目的介绍一种通用扫描校准器(SC),并通过与先前发表的两种SC的比较,评估其在校准口内扫描方案(CISP)中的准确性。材料和方法在无牙种植体模型上对三种SC进行评估,该模型包含位于螺钉保留基台(SRA)水平的六个扫描体(SBs):(1)具有c形窗口的通用SC (SC- cw),(2)仅覆盖牙槽嵴(SC- r)的SC,以及(3)仅限于腭区(SC- p)的SC。每个SC附着在模型上,使用口内扫描仪(IOS)扫描10次。随后使用相应的sc桌面扫描作为参考数据对口腔内扫描进行校正。模型的桌面扫描作为参考。测试扫描通过以下方式叠加到参考扫描上:(1)使用所有SBs来评估整体契合度,(2)使用第一和第二SBs来模拟虚拟谢菲尔德测试。使用Python脚本测量sra的线性和角偏差。结果校正后,三组的准确性和线性精度均有显著提高。在虚拟谢菲尔德测试中,校正后的正确度或角精度在SRA6结束时没有统计学上的显著差异。校正后,三组均达到临床可接受的正确率和精度值。结论三种SCs在体外条件下均获得临床可接受的印迹。新颖的SC代表了一种有前途的CISP方法;然而,还需要进一步的体内临床证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Oral Implants Research
Clinical Oral Implants Research 医学-工程:生物医学
CiteScore
7.70
自引率
11.60%
发文量
149
审稿时长
3 months
期刊介绍: Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书