Placement Error and Bone Regeneration of Customized Titanium Mesh With Vacuum-Formed Placing Template for Anterior Maxillary Bone Defects: A Retrospective Case Series Study
Shunhao Zhang, Mi Zhou, Yuxuan Zhao, Wen Chen, Xiaoxiao Cai
{"title":"Placement Error and Bone Regeneration of Customized Titanium Mesh With Vacuum-Formed Placing Template for Anterior Maxillary Bone Defects: A Retrospective Case Series Study","authors":"Shunhao Zhang, Mi Zhou, Yuxuan Zhao, Wen Chen, Xiaoxiao Cai","doi":"10.1111/clr.70115","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To evaluate placement error, bone regeneration, and mesh exposure of three-dimensionally printed customized titanium mesh (3DPC Ti-mesh) guided by a vacuum-formed placing template in guided bone regeneration (GBR) for anterior maxillary defects.</p>\n </section>\n \n <section>\n \n <h3> Material and Methods</h3>\n \n <p>10 patients (23 implants) with Terheyden 2/4 or 3/4 defects were included. CBCT data of pre-operation (T0), immediate post-operation (T2), and 5–8 months post-operation (T3) were reconstructed. These three models and preoperative design (T1) model were co-registered to a common coordinate system. Mesh displacement and contour discrepancy were measured. Bone regeneration was evaluated in terms of bone volume and implant-related bone height and width. Classification, time, and rate of mesh exposures were recorded.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Ti-mesh exhibited 0.57 ± 0.65 mm buccal displacement from T1 to T2 and 0.58 ± 0.57 mm apical displacement from T2 to T3. Mesh contour discrepancy was 0.70 ± 0.20 mm between T1 and T2 and decreased to 0.37 ± 0.12 mm between T2 and T3. Comparing T2 to T1, graft volume accuracy reached 91.1% ± 7.6%. Non-infected mesh exposure occurred in 26% implant sites. From T2 to T3, vertical bone resorption of 1.69 ± 1.56 mm and 0.14 ± 0.63 mm were recorded in exposed and non-exposed groups, respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>To our knowledge, this is the first study to validate the use of a vacuum-formed template for positioning 3DPC Ti-mesh. Within the study limitations, this technique is a feasible approach for placing customized mesh in anterior maxillary GBR.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"37 6","pages":"731-746"},"PeriodicalIF":5.9000,"publicationDate":"2026-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.70115","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To evaluate placement error, bone regeneration, and mesh exposure of three-dimensionally printed customized titanium mesh (3DPC Ti-mesh) guided by a vacuum-formed placing template in guided bone regeneration (GBR) for anterior maxillary defects.
Material and Methods
10 patients (23 implants) with Terheyden 2/4 or 3/4 defects were included. CBCT data of pre-operation (T0), immediate post-operation (T2), and 5–8 months post-operation (T3) were reconstructed. These three models and preoperative design (T1) model were co-registered to a common coordinate system. Mesh displacement and contour discrepancy were measured. Bone regeneration was evaluated in terms of bone volume and implant-related bone height and width. Classification, time, and rate of mesh exposures were recorded.
Results
Ti-mesh exhibited 0.57 ± 0.65 mm buccal displacement from T1 to T2 and 0.58 ± 0.57 mm apical displacement from T2 to T3. Mesh contour discrepancy was 0.70 ± 0.20 mm between T1 and T2 and decreased to 0.37 ± 0.12 mm between T2 and T3. Comparing T2 to T1, graft volume accuracy reached 91.1% ± 7.6%. Non-infected mesh exposure occurred in 26% implant sites. From T2 to T3, vertical bone resorption of 1.69 ± 1.56 mm and 0.14 ± 0.63 mm were recorded in exposed and non-exposed groups, respectively.
Conclusions
To our knowledge, this is the first study to validate the use of a vacuum-formed template for positioning 3DPC Ti-mesh. Within the study limitations, this technique is a feasible approach for placing customized mesh in anterior maxillary GBR.
期刊介绍:
Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.